implant loosening
Recently Published Documents


TOTAL DOCUMENTS

141
(FIVE YEARS 17)

H-INDEX

15
(FIVE YEARS 0)

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
ZhiBo Deng ◽  
JiangPing Wu ◽  
KaiYing Tang ◽  
Han Shu ◽  
Ting Wang ◽  
...  

Abstract Objectives It remains debatable if early mobilization (EM) yields a better clinical outcome than the late mobilization (LM) in adults with an acute and displaced distal radial fracture (DRF) of open reduction internal fixation (ORIF). Therefore, we aimed to perform a systematic review and meta-analysis of randomized controlled trials (RCTs), comparing clinical results with the safety of EM with LM following ORIF. Methods Databases such as Medline, Cochrane Central Register, and Embase were searched from Jan 1, 2000, to July 31, 2021, and RCTs comparing EM with LM for DRF with ORIF were included in the analysis. The primary outcome of study included disabilities of the Arm, Shoulder, and Hand (DASH) score at different follow-up times. Wherever the secondary outcomes included patient-rated wrist evaluation (PRWE), grip strength (GS), visual analog scale (VAS), wrist range of motion (WROM), and associated complications, the two independent reviewers did data extraction for the analysis. Effect sizes of outcome for each group were pooled using random-effects models; thereafter, the results were represented in the forest plots. Results Nine RCTs with 293 EM and 303 LM participants were identified and included in the study. Our analysis showed that the DASH score of the EM group was significantly better than LM group at the six weeks postoperatively (− 10.15; 95% CI − 15.74 to − 4.57, P < 0.01). Besides, the EM group also had better outcomes in PRWE, GS and WROM at 6 weeks. However, EM showed potential higher rate for implant loosening and/or fracture re-displacement complication (3.00; 95% CI 1.02–8.83, P = 0.05). Conclusion Functionally, at earlier stages, EM for patients with DRF of ORIF may have a beneficial effect than LM. The mean differences in the DASH score at 6 weeks surpassed the minimal clinically important difference; however, the potentially higher risk of implant loosening and/or fracture re-displacement cannot be ignored. Due to the lack of definitive evidence, multicenter and large sample RCTs are required for determining the optimal rehabilitation protocol for DRF with ORIF. PROSPERO registration number: CRD42021240214 2021/2/28.



2021 ◽  
Author(s):  
Ryo Sasaki ◽  
Masaki Nagashima ◽  
Toshiro Otani ◽  
Yoshifumi Okada ◽  
Noriyuki Aibara ◽  
...  

Abstract Introduction: In cemented total knee arthroplasty (TKA), pressurized carbon dioxide (CO2) lavage prior to cement fixation can eliminate debris at the bone-cement interface and is considered effective for increasing cement penetration and preventing aseptic loosening. Regarding the risk of a preliminary diagnosis of implant loosening, a radiolucent line (RLL) is a valuable sign. The purpose of this study was to compare the incidence of a tibial RLL at 2 years after TKA with and without pressurized CO2 lavage.Methods: This is a retrospective study. One hundred knees from 98 patients were enrolled in this study. TKA was performed without pressurized CO2 lavage (CO2- group) for the first 47 knees, and with pressurized CO2 lavage (CO2+ group) for the next 53 knees. The depth of cement penetration was measured just after surgery, and the incidence of tibial RLL >2 mm, at 2 years after TKA was determined. Results: Significant differences between groups were not seen regarding pre- and postoperative clinical factors. The depth of cement penetration in each area was significantly higher in the CO2+ group. The frequency of knees with RLL >2 mm was significantly lower in the CO2+ group than in the CO2- group (p<0.001).Conclusions: Pressurized CO2 lavage improved cement penetration and decreased the incidence of tibial RLL >2 mm at 2 years after TKA. Since the RLL has been reported as a valuable sign for preliminary diagnosis of loosening, pressurized CO2 lavage appears effective for preventing loosening.



2021 ◽  
pp. 57-61
Author(s):  
Inês Simões Peres ◽  
Jorge A.F. Ferreira ◽  
Marco P. Soares ​dos Santos


2021 ◽  
Vol 19 (1) ◽  
Author(s):  
Wei Liu ◽  
Muyu Yu ◽  
Feng Chen ◽  
Longqing Wang ◽  
Cheng Ye ◽  
...  

Abstract Background Many patients suffer from implant loosening after the implantation of titanium alloy caused by immune response to the foreign bodies and this could inhibit the following osteogenesis, which could possibly give rise to aseptic loosening and poor osteointegration while there is currently no appropriate solution in clinical practice. Exosome (Exo) carrying miRNA has been proven to be a suitable nanocarrier for solving this problem. In this study, we explored whether exosomes overexpressing miR-181b (Exo-181b) could exert beneficial effect on promoting M2 macrophage polarization, thus inhibiting inflammation as well as promoting osteogenesis and elaborated the underlying mechanism in vitro. Furthermore, we aimed to find whether Exo-181b could enhance osteointegration. Results In vitro, we firstly verified that Exo-181b significantly enhanced M2 polarization and inhibited inflammation by suppressing PRKCD and activating p-AKT. Then, in vivo, we verified that Exo-181b enhanced M2 polarization, reduced the inflammatory response and enhanced osteointegration. Also, we verified that the enhanced M2 polarization could indirectly promote the migration and osteogenic differentiation by secreting VEGF and BMP-2 in vitro. Conclusions Exo-181b could suppress inflammatory response by promoting M2 polarization via activating PRKCD/AKT signaling pathway, which further promoting osteogenesis in vitro and promote osteointegration in vivo. Graphic abstract



2021 ◽  
Vol 12 ◽  
Author(s):  
Elysia A. Masters ◽  
Gowrishankar Muthukrishnan ◽  
Lananh Ho ◽  
Ann Lindley Gill ◽  
Karen L. de Mesy Bentley ◽  
...  

Staphylococcus aureus invasion of the osteocyte lacuno-canalicular network (OLCN) is a novel mechanism of bacterial persistence and immune evasion in chronic osteomyelitis. Previous work highlighted S. aureus cell wall transpeptidase, penicillin binding protein 4 (PBP4), and surface adhesin, S. aureus surface protein C (SasC), as critical factors for bacterial deformation and propagation through nanopores in vitro, representative of the confined canaliculi in vivo. Given these findings, we hypothesized that cell wall synthesis machinery and surface adhesins enable durotaxis- and haptotaxis-guided invasion of the OLCN, respectively. Here, we investigated select S. aureus cell wall synthesis mutants (Δpbp3, Δatl, and ΔmreC) and surface adhesin mutants (ΔclfA and ΔsasC) for nanopore propagation in vitro and osteomyelitis pathogenesis in vivo. In vitro evaluation in the microfluidic silicon membrane-canalicular array (μSiM-CA) showed pbp3, atl, clfA, and sasC deletion reduced nanopore propagation. Using a murine model for implant-associated osteomyelitis, S. aureus cell wall synthesis proteins were found to be key modulators of S. aureus osteomyelitis pathogenesis, while surface adhesins had minimal effects. Specifically, deletion of pbp3 and atl decreased septic implant loosening and S. aureus abscess formation in the medullary cavity, while deletion of surface adhesins showed no significant differences. Further, peri-implant osteolysis, osteoclast activity, and receptor activator of nuclear factor kappa-B ligand (RANKL) production were decreased following pbp3 deletion. Most notably, transmission electron microscopy (TEM) imaging of infected bone showed that pbp3 was the only gene herein associated with decreased submicron invasion of canaliculi in vivo. Together, these results demonstrate that S. aureus cell wall synthesis enzymes are critical for OLCN invasion and osteomyelitis pathogenesis in vivo.



2021 ◽  
Author(s):  
Connor Huxman ◽  
Jared Butler

Abstract Currently available motion-preserving orthopedic implants offer many advantages but have several limitations to their use, including short device lifetime, high part count, loss of natural kinematics and wear-induced osteolysis and implant loosening. Compliant mechanisms have been used to address some of these problems as they offer several potential advantages - namely wear reduction, reduced part count, and the ability to achieve complex, patient-specific motion profiles. This article provides a systematic review of compliant mechanisms as orthopedic implants. Based on the PRISMA guidelines for an efficient review, this work identified fourteen implantable orthopedic devices that seek to restore anatomical motion by utilizing mechanical compliance. From reviewing these implants and their results, advantages and consequences for each are summarized. Trends were also identified in how these devices are capable of mitigating common challenges found in orthopedic design. Design considerations for the development of future compliant orthopedic implants are proposed and discussed.



2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Olof Sandberg ◽  
Henrik Olivecrona ◽  
Pelle Gustafson

Adverse events in total hip replacement (THR) may have several origins, one being lack of precision in diagnosis and/or during surgery. This study describes the pattern and frequency of avoidable injuries in THR and the potential value of a new tool for early diagnosis of implant loosening. This retrospective study was based on all (n = 1 456) settled claims regarding THR in the Swedish National Patient Insurance database from 2010 to 2017. The claims and medical records were analyzed for root causes, with special focus on adverse events where lack of precision could be the cause. In a second stage, we assessed in 10 patients (20 implants) the diagnostic precision of a new software tool based on provocation-CT. These were all patients where the implant loosening diagnosis was deemed as inconclusive after a first plain X-ray. The findings from the provocation-CT and plain X-ray were compared to the surgical findings at revision. While 3 of 20 implants were correctly diagnosed with plain X-ray, for dynamic CT, this number was 14 of 20 implants. The retrospective study showed that the most common types of injuries were infections (34%), nerve injury (29%), mechanical problems (14.5%), dislocation (6%), and miscellaneous complications (16.5%). Of the patients with mechanical complications, one-third had aseptic implant loosening. Statement of clinical significance: we estimated that almost 200 patients in our registry study had mechanical complications after THR, mainly implant loosening. A third of these could potentially have been diagnosed and treated if CT examination with a dedicated image analysis tool to assess implant loosening after THR had been available.



2021 ◽  
Vol 6 (6) ◽  
pp. 459-471
Author(s):  
George C. Babis ◽  
Vasileios S. Nikolaou

Pelvic discontinuity (PD) has been a considerable challenge for the hip revision arthroplasty surgeon. However, not all PDs are the same. Some occur during primary cup insertion, resembling a fresh periprosthetic fracture that separates the superior and inferior portions of the pelvis, while others are chronic as a result of gradual acetabular bone loss due to osteolysis and/or acetabular implant loosening. In the past, ORIF, various types of cages, bone grafts and bone cement were utilized with little success. Today, the biomechanics and biology of PD as well as new diagnostic tools and especially a variety of new implants and techniques are available to hip revision surgeons. Ultraporous cups and augments, cup-cage constructs and custom triflange components have revolutionized the treatment of PD when used in various combinations with ORIF and bone grafts. For chronic PD the cup-cage construct is the most popular method of reconstruction with good medium-term results. Dislocation continues to be the leading cause of failure in all situations, followed by infection. Ultimately, surgeons today have a big enough armamentarium to select the best treatment approach. Case individualization, personal experience and improvisation are the best assets to drive treatment decisions and strategies. Cite this article: EFORT Open Rev 2021;6:459-471. DOI: 10.1302/2058-5241.6.210022



2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Nupur Kohli ◽  
Jennifer C. Stoddart ◽  
Richard J. van Arkel

AbstractMuch research effort is being invested into the development of porous biomaterials that enhance implant osseointegration. Large micromotions at the bone-implant interface impair this osseointegration process, resulting in fibrous capsule formation and implant loosening. This systematic review compiled all the in vivo evidence available to establish if there is a universal limit of tolerable micromotion for implant osseointegration. The protocol was registered with the International Prospective Register for Systematic Reviews (ID: CRD42020196686). Pubmed, Scopus and Web of Knowledge databases were searched for studies containing terms relating to micromotion and osseointegration. The mean value of micromotion for implants that osseointegrated was 32% of the mean value for those that did not (112 ± 176 µm versus 349 ± 231 µm, p < 0.001). However, there was a large overlap in the data ranges with no universal limit apparent. Rather, many factors were found to combine to affect the overall outcome including loading time, the type of implant and the material being used. The tables provided in this review summarise these factors and will aid investigators in identifying the most relevant micromotion values for their biomaterial and implant development research.



2021 ◽  
Vol 11 (5) ◽  
Author(s):  
Mandeep S. Dhillon ◽  
Pulak Vatsya ◽  
Sarvdeep S. Dhatt ◽  
Vishal Kumar ◽  
Prasoon Kumar

Introduction: Implant wear and loosening with eluding metal/polythene debris are commonly implicated in the occurrence of Baker’s cysts in post-operative total knee replacement (TKR) patients, who present with post-operative pain and swelling, mimicking deep venous thrombosis. However, we present two symptomatic cases presenting with ruptured Baker’s cysts post-TKRs, with no evidence of implant loosening or wear. Cases Report: The 1st patient was a 55-year-old male, who underwent TKR for Grade 4 bilateral knee osteoarthritis and presented with acute onset of pain and swelling over the left popliteal fossa, which progressed to involve the calf. Radiographs showed no sign of infection or loosening, and venous color Doppler and magnetic resonance imaging (MRI) showed a hy-poechoic collection in the intermuscular plane at the upper part of popliteal fossa. Histological examination of the aspirated fluid showed mixed features of cystic fluid and a resolving hematoma. There was complete resolution of the 4 months with rest and graduated physiotherapy. The 2nd patient was a 51-year-old female who developed the cystic swelling 2 years after the surgery, and the ultrasound showed hypoechoic echoes in a Baker’s cyst-like collection. Cytological findings were suggestive of hemorrhagic nature of the aspirate, without any evi-dence of polyethylene debris, and the cultures were sterile. She became asymptomatic over 4 weeks with conservative management; the swelling resolved after 3 months. Conclusion: Majority of the cases in literature show implant loosening as cause of popliteal cysts after TKRs, however present cases highlight alternative mechanisms, and there are good chances of self-resolution of cysts with conservative treatment in such cases. Keywords: Knee replacement, Baker’s cyst, deep vein thrombosis, ruptured popliteal cyst.



Sign in / Sign up

Export Citation Format

Share Document