Malignant or Benign Subepithelial Tumors (Set) In The Upper Gastrointestinal Tract <20MM: Curative and Diagnostic Endoscopic Resection: Retrospective Study of 102 Patients

2021 ◽  
Author(s):  
F Caillol ◽  
E Meunier ◽  
C Zemmour ◽  
Ratone JP ◽  
C Pesenti ◽  
...  
Endoscopy ◽  
2015 ◽  
Vol 47 (08) ◽  
pp. 675-679 ◽  
Author(s):  
Ji Song ◽  
Sang Kim ◽  
Su Chung ◽  
Hae Kang ◽  
Sun Yang ◽  
...  

2010 ◽  
Vol 56 (5) ◽  
pp. 645-647
Author(s):  
Hiroshi Fujita ◽  
Shigeko Nishimura ◽  
Saiko Kurosawa ◽  
Yuki Hazama ◽  
Emi Yamamoto ◽  
...  

2020 ◽  
Vol 08 (10) ◽  
pp. E1291-E1301
Author(s):  
Mouen A. Khashab ◽  
Reem Z. Sharaiha ◽  
Kaveh Hajifathalian ◽  
Yervant Ichkhanian ◽  
Qais Dawod ◽  
...  

Abstract Background and study aims The Full-Thickness Resection Device (FTRD) provides a novel treatment option for lesions not amenable to conventional endoscopic resection techniques. There are limited data on the efficacy and safety of FTRD for resection of upper gastrointestinal tract (GIT) lesions. Patients and methods This was an international multicenter retrospective study, including patients who had an endoscopic resection of an upper GIT lesion using the FTRD between January 2017 and February 2019. Results Fifty-six patients from 13 centers were included. The most common lesions were mesenchymal neoplasms (n = 23, 41 %), adenomas (n = 7, 13 %), and hamartomas (n = 6, 11 %). Eighty-four percent of lesions were located in the stomach, and 14 % in the duodenum. The average size of lesions was 14 mm (range 3 to 33 mm). Deployment of the FTRD was technically successful in 93 % of patients (n = 52) leading to complete and partial resection in 43 (77 %) and 9 (16 %) patients, respectively. Overall, the FTRD led to negative histological margins (R0 resection) in 38 (68 %) of patients. A total of 12 (21 %) mild or moderate adverse events (AEs) were reported. Follow-up endoscopy was performed in 31 patients (55 %), on average 88 days after the procedure (IQR 68–138 days). Of these, 30 patients (97 %) did not have any residual or recurrent lesion on endoscopic examination and biopsy, with residual adenoma in one patient (3 %). Conclusions Our results suggest a high technical success rate and an acceptable histologically complete resection rate, with a low risk of AEs and early recurrence for FTRD resection of upper GIT lesions.


2017 ◽  
Vol 05 (03) ◽  
pp. E165-E171 ◽  
Author(s):  
Christoph Schlag ◽  
Christoph Menzel ◽  
Manuela Götzberger ◽  
Simon Nennstiel ◽  
Peter Klare ◽  
...  

Abstract Background and study aims The optimal approach to small subepithelial tumors (SETs) of the upper gastrointestinal tract remains inconclusive. The aim of this study was to evaluate endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) for less invasive tissue sampling of small SETs of the upper gastrointestinal tract. Patients and methods In this prospective observational study patients with small ( ≤ 3 cm) SETs of the upper gastrointestinal tract were eligible and underwent EUS-FNB with a 22-gauge core biopsy needle. The main outcome measure was the diagnostic yield. The number of obtained core biopsies was also assessed. Results Twenty patients were included. The mean SET size was 16 mm (range 10 – 27 mm). EUS-FNB was technically feasible in all cases and no complications were observed. The diagnostic yield was 75 %. Core biopsy specimens were obtained in only 25 % of cases. Conclusion EUS-FNB with a 22-gauge core biopsy needle of small SETs can achieve a definite diagnosis in the majority of cases. However, because core samples cannot regularly be obtained, EUS-FNB seems not to be convincingly superior to standard EUS-FNA in this setting


2020 ◽  
Vol 11 (03) ◽  
pp. 242-244
Author(s):  
Maximilian Gericke ◽  
Matthias Mende ◽  
Dirk Hartmann ◽  
Siegbert Faiss

Abstract Introduction Surgical resection of adenomas or subepithelial tumors in the duodenum has a high morbidity compared with endoscopic resection which also has a significant risk of complication. Endoscopic full-thickness resection has shown its feasibility and safety in the colorectum and in the upper gastrointestinal tract. Patient and Methods We present the new gastroduodenal full-thickness resection device (FTRD) for full-thickness resection in a patient with a recurrent nonlifting adenoma in the nonampullary duodenum. Results The procedure was successful with R0 resection without major complications. A control gastroscopy showed no recurrence of the adenoma. Conclusion The gastroduodenal FTRD seems to be a promising new technique for resecting nonlifting adenomas in the nonampullary duodenum.


Sign in / Sign up

Export Citation Format

Share Document