Bowel Preparations Regimens for Colon Capsule Endoscopy – a Systematic Review and Meta-Analysis

2021 ◽  
Author(s):  
T Bjoersum-Meyer ◽  
K Skonieczna-Zydecka ◽  
P Cortegoso Valdivia ◽  
I Stenfors ◽  
I Lutakov ◽  
...  
2021 ◽  
Vol 93 (6) ◽  
pp. AB100
Author(s):  
Marianny Sulbaran ◽  
Wanderley M. Bernardo ◽  
Leonardo A. Bustamante-Lopez ◽  
Christiano M. Sakai ◽  
Paulo Sakai ◽  
...  

2010 ◽  
Vol 71 (5) ◽  
pp. AB244 ◽  
Author(s):  
Cristiano Spada ◽  
Cesare Hassan ◽  
Riccardo Marmo ◽  
Angelo Zullo ◽  
Paola Cesaro ◽  
...  

2021 ◽  
Vol 09 (11) ◽  
pp. E1658-E1673
Author(s):  
Thomas Bjoersum-Meyer ◽  
Karolina Skonieczna-Zydecka ◽  
Pablo Cortegoso Valdivia ◽  
Irene Stenfors ◽  
Ivan Lyutakov ◽  
...  

Abstract Background and study aims Colon capsule endoscopy (CCE) is an alternative to conventional colonoscopy (CC) in specific clinical settings. High completion rates (CRs) and adequate cleanliness rates (ACRs) are fundamental quality parameters if CCE is to be widely implemented as a CC equivalent diagnostic modality. We conducted a systematic review and meta-analysis to investigate the efficacy of different bowel preparations regimens on CR and ACR in CCE. Patients and methods We performed a systematic literature search in PubMed, Embase, CINAHL, Web of Science, and the Cochrane Library. Data were independently extracted per the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). The primary outcome measures (CR, ACR) were retrieved from the individual studies and pooled event rates were calculated. Results Thirty-four observational (OBS) studies (n = 3,789) and 12 randomized clinical trials (RCTs) (n = 1,214) comprising a total 5,003 patients were included. The overall CR was 0.798 (95 % CI, 0.764–0.828); the highest CRs were observed with sodium phosphate (NaP) + gastrografin booster (n = 2, CR = 0.931, 95 % CI, 0.820–0.976). The overall ACR was 0.768 (95 % CI, 0.735–0.797); the highest ACRs were observed with polyethylene glycol (PEG) + magnesium citrate (n = 4, ER = 0.953, 95 % CI, 0.896–0.979). Conclusions In the largest meta-analysis on CCE bowel preparation regimens, we found that both CRs and ACRs are suboptimal compared to the minimum recommended standards for CC. PEG laxative and NaP booster were the most commonly used but were not associated with higher CRs or ACRs. Well-designed studies on CCE should be performed to find the optimal preparation regimen.


2021 ◽  
Vol 09 (04) ◽  
pp. E562-E571
Author(s):  
Tobias Möllers ◽  
Matthias Schwab ◽  
Lisa Gildein ◽  
Michael Hoffmeister ◽  
Jörg Albert ◽  
...  

Abstract Background and study aims Adherence to colorectal cancer (CRC) screening is still unsatisfactory in many countries, thereby limiting prevention of CRC. Colon capsule endoscopy (CCE), a minimally invasive procedure, could be an alternative to fecal immunochemical tests or optical colonoscopy for CRC screening, and might increase adherence in CRC screening. This systematic review and meta-analysis evaluates the diagnostic accuracy of CCE compared to optical colonoscopy (OC) as the gold standard, adequacy of bowel preparation regimes and the patient perspective on diagnostic measures. Methods We conducted a systematic literature search in PubMed, EMBASE and the Cochrane Register for Clinical Trials. Pooled estimates for sensitivity, specificity and the diagnostic odds ratio with their respective 95 % confidence intervals (CI) were calculated for studies providing sufficient data. Results Of 840 initially identified studies, 13 were included in the systematic review and up to 9 in the meta-analysis. The pooled sensitivities and specificities for polyps ≥ 6 mm were 87 % (95 % CI: 83 %–90 %) and 87 % (95 % CI: 76 %–93 %) in 8 studies, respectively. For polyps ≥ 10 mm, the pooled estimates for sensitivities and specificities were 87 % (95 % CI: 83 %–90 %) and 95 % (95 % CI: 92 %–97 %) in 9 studies, respectively. A patients’ perspective was assessed in 31 % (n = 4) of studies, and no preference of CCE over OC was reported. Bowel preparation was adequate in 61 % to 92 % of CCE exams. Conclusions CCE provides high diagnostic accuracy in an adequately cleaned large bowel. Conclusive findings on patient perspectives require further studies to increase acceptance/adherence of CCE for CRC screening.


Endoscopy ◽  
2021 ◽  
Author(s):  
Fanny E. R. Vuik ◽  
Stella A. V. Nieuwenburg ◽  
Sarah Moen ◽  
Cristiano Spada ◽  
Carlo Senore ◽  
...  

Abstract Introduction Primary colonoscopy and fecal immunochemical test (FIT) are the most commonly used colorectal cancer (CRC) screening modalities. Colon capsule endoscopy (CCE) might be an alternative. Data on the performance of CCE as a CRC screening tool in a screening population remain scarce. This is the first systematic review to provide an overview of the applicability of CCE as a CRC screening tool. Methods A systematic search was conducted of literature published up to September 2020. Studies reporting on CRC screening by second-generation CCE in an average-risk screening population were included. Results 582 studies were identified and 13 were included, comprising 2485 patients. Eight studies used CCE as a filter test after a positive FIT result and five studies used CCE for primary screening. The polyp detection rate of CCE was 24 % – 74 %. For polyps > 6 mm, sensitivity of CCE was 79 % – 96 % and specificity was 66 % – 97 %. For polyps ≥ 10 mm, sensitivity of CCE was 84 % – 97 %, which was superior to computed tomographic colonography (CTC). The CRC detection rate for completed CCEs was 93 % (25/27). Bowel preparation was adequate in 70 % – 92 % of examinations, and completion rates varied from 57 % to 92 %, depending on the booster used. No CCE-related complications were described. Conclusion CCE appeared to be a safe and effective tool for the detection of CRC and polyps in a screening setting. Accuracy was comparable to colonoscopy and superior to CTC, making CCE a good alternative to colonoscopy in CRC screening programs, although completion rates require improvement.


Cancers ◽  
2020 ◽  
Vol 12 (11) ◽  
pp. 3367
Author(s):  
Ulrik Deding ◽  
Lasse Kaalby ◽  
Henrik Bøggild ◽  
Eva Plantener ◽  
Mie Kruse Wollesen ◽  
...  

Following incomplete colonoscopy (IC) patients often undergo computed tomography colonography (CTC), but colon capsule endoscopy (CCE) may be an alternative. We compared the completion rate, sensitivity and diagnostic yield for polyp detection from CCE and CTC following IC. A systematic literature search resulted in twenty-six studies. Extracted data included inter alia, complete/incomplete investigations and polyp findings. Pooled estimates of completion rates of CCE and CTC and complete colonic view rates (CCE reaching the most proximal point of IC) of CCE were calculated. Per patient diagnostic yields of CCE and CTC were calculated stratified by polyp sizes. CCE completion rate and complete colonic view rate were 76% (CI 95% 68–84%) and 90% (CI 95% 83–95%). CTC completion rate was 98% (CI 95% 96–100%). Diagnostic yields of CTC and CCE were 10% (CI 95% 7–15%) and 37% (CI 95% 30–43%) for any size, 13% (CI 95% 9–18%) and 21% (CI 95% 12–32%) for >5-mm and 4% (CI 95% 2–7%) and 9% (CI 95% 3–17%) for >9-mm polyps. No study performed a reference standard follow-up after CCE/CTC in individuals without findings, rendering sensitivity calculations unfeasible. The increased diagnostic yield of CCE could outweigh its slightly lower complete colonic view rate compared to the superior CTC completion rate. Hence, CCE following IC appears feasible for an introduction to clinical practice. Therefore, randomized studies investigating CCE and/or CTC following incomplete colonoscopy with a golden standard reference for the entire population enabling estimates for sensitivity and specificity are needed.


2010 ◽  
Vol 8 (6) ◽  
pp. 516-522.e8 ◽  
Author(s):  
Cristiano Spada ◽  
Cesare Hassan ◽  
Riccardo Marmo ◽  
Lucio Petruzziello ◽  
Maria Elena Riccioni ◽  
...  

2009 ◽  
Vol 69 (5) ◽  
pp. AB375
Author(s):  
Theodore Rokkas ◽  
Konstantinos Papaxoinis ◽  
Konstantinos Triantafyllou ◽  
Spiros D. Ladas

2010 ◽  
Vol 71 (4) ◽  
pp. 792-798 ◽  
Author(s):  
Theodore Rokkas ◽  
Konstantinos Papaxoinis ◽  
Konstantinos Triantafyllou ◽  
Spiros D. Ladas

Sign in / Sign up

Export Citation Format

Share Document