scholarly journals Beta-Ray Dose Assessment from Skin Contamination Using a Point Kernel Method

2008 ◽  
Vol 45 (sup5) ◽  
pp. 313-316
Author(s):  
Sang-hyun Park ◽  
Bo-yeol Choi ◽  
Jai-ki Lee
2020 ◽  
Vol 177 ◽  
pp. 109146
Author(s):  
Yong-kuo Liu ◽  
Li-qun Yang ◽  
Min-jun Peng ◽  
Nan Chao ◽  
Abiodun Ayodeji ◽  
...  

2014 ◽  
Vol 7 (1) ◽  
pp. 107
Author(s):  
Ilyes Elaissi ◽  
Okba Taouali ◽  
Messaoud Hassani

Author(s):  
Hirosato SEKI ◽  
Fuhito MIZUGUCHI ◽  
Satoshi WATANABE ◽  
Hiroaki ISHII ◽  
Masaharu MIZUMOTO

2014 ◽  
Vol 6 (1) ◽  
pp. 1006-1015
Author(s):  
Negin Shagholi ◽  
Hassan Ali ◽  
Mahdi Sadeghi ◽  
Arjang Shahvar ◽  
Hoda Darestani ◽  
...  

Medical linear accelerators, besides the clinically high energy electron and photon beams, produce other secondary particles such as neutrons which escalate the delivered dose. In this study the neutron dose at 10 and 18MV Elekta linac was obtained by using TLD600 and TLD700 as well as Monte Carlo simulation. For neutron dose assessment in 2020 cm2 field, TLDs were calibrated at first. Gamma calibration was performed with 10 and 18 MV linac and neutron calibration was done with 241Am-Be neutron source. For simulation, MCNPX code was used then calculated neutron dose equivalent was compared with measurement data. Neutron dose equivalent at 18 MV was measured by using TLDs on the phantom surface and depths of 1, 2, 3.3, 4, 5 and 6 cm. Neutron dose at depths of less than 3.3cm was zero and maximized at the depth of 4 cm (44.39 mSvGy-1), whereas calculation resulted  in the maximum of 2.32 mSvGy-1 at the same depth. Neutron dose at 10 MV was measured by using TLDs on the phantom surface and depths of 1, 2, 2.5, 3.3, 4 and 5 cm. No photoneutron dose was observed at depths of less than 3.3cm and the maximum was at 4cm equal to 5.44mSvGy-1, however, the calculated data showed the maximum of 0.077mSvGy-1 at the same depth. The comparison between measured photo neutron dose and calculated data along the beam axis in different depths, shows that the measurement data were much more than the calculated data, so it seems that TLD600 and TLD700 pairs are not suitable dosimeters for neutron dosimetry in linac central axis due to high photon flux, whereas MCNPX Monte Carlo techniques still remain a valuable tool for photonuclear dose studies.


2013 ◽  
Vol 756-759 ◽  
pp. 3652-3658
Author(s):  
You Li Lu ◽  
Jun Luo

Under the study of Kernel Methods, this paper put forward two improved algorithm which called R-SVM & I-SVDD in order to cope with the imbalanced data sets in closed systems. R-SVM used K-means algorithm clustering space samples while I-SVDD improved the performance of original SVDD by imbalanced sample training. Experiment of two sets of system call data set shows that these two algorithms are more effectively and R-SVM has a lower complexity.