scholarly journals P2598Is pressure wire useful to predict reperfusion pulmonary edema after balloon pulmonary angioplasty in chronic thromboembolic pulmonary hypertension?

2017 ◽  
Vol 38 (suppl_1) ◽  
Author(s):  
M.T. Velazquez Martin ◽  
A. Albarran ◽  
I. Hernandez ◽  
S. Mayordomo ◽  
Y. Revilla ◽  
...  
2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
Y Nagamatsu ◽  
T Inami ◽  
C Nakata ◽  
K Takeuchi ◽  
H Kikuchi ◽  
...  

Abstract Background Balloon pulmonary angioplasty (BPA) in expert center may be considered in patients with chronic thromboembolic pulmonary hypertension (CTEPH) who are technically non-operable for pulmonary endarterectomy. BPA based on objective quantitative methods has not been established. The endpoint at BPA sessions has not been clarified yet. Objectives The purpose of this study was to investigate the usefulness of BPA according to peripheral pressure measured by pressure wire or catheter. Methods This study included consecutive 143 CTEPH who underwent cardiopulmonary exercise test with right heart catheterization after BPA. All patients were divided into 2 groups such as angio-guided (n=47) group or pressure-guidedgroup (n=96). In pressure-guided group, the pulmonary arterial pressure (PAP) proximal and distal to the target lesion and the ratio of the 2 pressures were measured by the pressure wire or catheter. the endpoint was determined to when the pressure ratio of distal to proximal pressures was >0.7 to 0.8 finally. The dilation was stopped when the distal mean PAP after each dilation reached 35 mm Hg and when the baseline mean PAP was >35 mm Hg. Changes of hemodynamic parameters such as PAP and pulmonary vascular resistance (PVR) from baseline, and mean PAP and PVR at peak oxygen consumption, and pulmonary arterial pressure – cardiac output (PA-CO) slope were compared between two groups. All data except changes of hemodynamics from baseline were expressed by median [25th percentile-75th percentile]. Changes of hemodynamics from baseline were expressed by average [95% confidence interval] Results The median age and male were 66 [56–72] years old and 35. There were no significant differences in number of sessions and dilated vessels between two groups (Angio-guided group vs. Pressure-guided group: 4 [3–6] vs. 4 [3–5], P>0.05; 19 [12–22] vs. 17 [13–22], P>0.05). Changes of PAP and PVR from baseline in pressure-guided group was significantly higher than in angio-guided groups (Angio-guided group vs. Pressure-guided group; ΔPAP: −19 [−20 to −17] vs. −20 [−21 to −20], P>0.05; ΔPVR: −6.0 [−6.3 to −5.7] vs. −6.6 [−6.8 to −6.3], P<0.01). Mean PAP and PVR at peak oxygen consumption (VO2) and PA-CO slope in pressure-guided group were significantly lower than in angio-guided group (Angio-guided group vs. Pressure-guided group; PAP at VO2: 43 [36–50] vs. 39 [34–43], P<0.05; PVR at VO2: 2.7 [1.9–4.5] vs. 2.2 [1.6–2.9], P<0.01; PA-CO slope: 3.8 [2.1–5.2] vs. 2.9 [1.9–4.0], P<0.05). Conclusions Peripheral-pressure-directed BPA can improve hemodynamics at rest and exercise more effectively. Funding Acknowledgement Type of funding source: None


Diagnostics ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 133
Author(s):  
Marta Banaszkiewicz ◽  
Arkadiusz Pietrasik ◽  
Michał Florczyk ◽  
Piotr Kędzierski ◽  
Michał Piłka ◽  
...  

Background: The aim of the study was to assess soluble ST2 (sST2) concentration and its dynamic changes in the periprocedural period in patients with chronic thromboembolic pulmonary hypertension (CTEPH) treated with balloon pulmonary angioplasty (BPA). Methods: We prospectively analyzed 57 procedures of BPA performed in 37 patients with CTEPH. Biomarkers, such as N-terminal pro B-type natriuretic peptide (NT-proBNP), troponin T (TnT), and sST2 were assessed at four time points: Before the BPA procedure, 24 h and 48 h after the procedure, and at the discharge from hospital. Each postprocedural period was assessed for complications. Results: Before the BPA procedure, median sST2 concentration was 26.56 ng/mL (IQR: 16.66–40.83 ng/mL). sST2 concentration was significantly higher 24 h and 48 h after the BPA compared to the baseline measurements (33.31 ng/mL (IQR: 20.81–62.56), p = 0.000 and 27.45 ng/mL (IQR: 17.66–54.45), p = 0.028, respectively). sST2 level 24 h after the BPA procedure was significantly higher in the group with complications compared to the group without complications in the postprocedural period (97.66 ng/mL (IQR: 53.07–126.18) vs. 26.86 ng/mL (IQR: 19.10–40.12), p = 0.000). Conclusions: sST2 concentration in patients with CTEPH treated with BPA changes significantly in the postprocedural period and is significantly higher in the group with complications in postprocedural period.


Sign in / Sign up

Export Citation Format

Share Document