Comparison of Mucosal Pressures Induced by Cuffs of Different Airway Devices

2006 ◽  
Vol 104 (5) ◽  
pp. 933-938 ◽  
Author(s):  
Herbert Ulrich-Pur ◽  
Franz Hrska ◽  
Peter Krafft ◽  
Helmut Friehs ◽  
Beatrix Wulkersdorfer ◽  
...  

Background High pressures exerted by balloons and cuffs of conventional endotracheal tubes, the Combitube (Tyco Healthcare Nellcor Mallinckrodt, Pleasanton, CA), the EasyTube (Teleflex Ruesch, Kernen, Germany), the Laryngeal Mask Airway (LMA North America, San Diego, CA), the Intubating Laryngeal Mask Airway (Fastrach; LMA North America), the ProSeal (LMA North America), and the Laryngeal Tube (LT; VBM Medizintechnik, Sulz, Germany) may traumatize the pharyngeal mucosa. The aim of this study was to compare pressures exerted on the pharyngeal, tracheal, and esophageal mucosa by different devices designed for securing the patient's airways. Methods Nineteen fresh cadavers were included. To measure mucosal pressures, microchip sensors were fixed on the anterior, lateral, and posterior surfaces of the proximal balloon and the distal cuff of the investigated devices. Depending on the respective airway device, the cuff volume was increased in 10-ml increments at the proximal balloon starting from 0 to a maximum of 100 ml, and in 2-ml increments at the distal cuff starting from 0 up to 12 ml. Results Tracheal mucosal pressures were significantly higher using the Combitube compared with the endotracheal tube and the EasyTube. Maximal esophageal pressures were significantly higher using the EasyTube compared with the Combitube. Using cuff volumes according to the manufacturers' guidelines, we found the highest pharyngeal pressures with the Intubating Laryngeal Mask Airway versus all other devices. At maximal volumes, the Laryngeal Mask Airway, the Intubating Laryngeal Mask Airway, and the ProSeal induced significantly higher pharyngeal pressures compared with all other devices. Using a pharyngeal cuff volume of 40 ml, the Intubating Laryngeal Mask Airway followed by the Laryngeal Mask Airway exerted significantly higher pressures compared with the other devices. Conclusions Although some devices exhibit a somewhat higher mucosal pressure when compared with others, the authors believe that the observed differences of the cuff pressures do not suggest a clinically relevant danger, because the investigated devices, except the endotracheal tubes, are not intended for prolonged use.

2001 ◽  
Vol 94 (6) ◽  
pp. 968-972 ◽  
Author(s):  
Olivier Langeron ◽  
François Semjen ◽  
Jean-Louis Bourgain ◽  
Alain Marsac ◽  
Anne-Marie Cros

Background The intubating laryngeal mask airway (ILMA; Fastrach; Laryngeal Mask Company, Henley-on-Thames, UK) may provide an alternative technique to fiberoptic intubation (FIB) to facilitate the management of the anticipated difficult airway. The authors therefore compared the effectiveness of the ILMA with FIB in patients with anticipated difficult intubation. Methods One hundred patients, with at least one difficult intubation criteria (Mallampati class III or IV, thyromental distance < 65 mm, interincisor distance < 35 mm) were enrolled (FIB group, n = 49; ILMA group, n = 51) in this prospective randomized study. Anesthesia was induced with propofol and maintained with alfentanil and propofol after an efficient mask ventilation has been demonstrated. The success of the technique (within three attempts), the number of attempts, duration of the successful attempt, and adverse events (oxygen saturation < 90%, bleeding) were recorded. Results The rate of successful tracheal intubation with ILMA was 94% and comparable with FIB (92%). The number of attempts and the time to succeed were not significantly different between groups. In case of failure of the first technique, the alternative technique always succeeded. Failures in FIB group were related to oxygen desaturation (oxygen saturation < 90%) and bleeding, and to previous cervical radiotherapy in the ILMA group. Adverse events occurred significantly more frequently in FIB group than in ILMA group (18 vs. 0%, P < 0.05). Conclusion The authors obtained a high success rate and comparable duration of tracheal intubation with ILMA and FIB techniques. In patients with previous cervical radiotherapy, the use of ILMA cannot be recommended. Nevertheless, the use of the ILMA was associated with fewer adverse events.


2016 ◽  
Vol 46 ◽  
pp. 1617-1623 ◽  
Author(s):  
Semih ÖZDİL ◽  
Zehra İpek ARSLAN AYDIN ◽  
Zehra Nur BAYKARA ◽  
Kamil TOKER ◽  
Zeynep Mine SOLAK

Sign in / Sign up

Export Citation Format

Share Document