scholarly journals Rigid Contact Lens Design Equivalencies of Overall Diameter and Axial Edge Lift: Individual Variations

1993 ◽  
Vol 70 (9) ◽  
pp. 733-738 ◽  
Author(s):  
BARBARA A. FINK ◽  
LEO G. CARNEY ◽  
RICHARD M. HILL
1991 ◽  
Vol 68 (3) ◽  
pp. 198-203 ◽  
Author(s):  
BARBARA A. FINK ◽  
LEO G. CARNEY ◽  
RICHARD M. HILL

1993 ◽  
Vol 70 (10) ◽  
pp. 781-784 ◽  
Author(s):  
BARBARA A. FINK ◽  
RICHARD M. HILL ◽  
LEO G. CARNEY

1995 ◽  
Vol 72 (SUPPLEMENT) ◽  
pp. 73
Author(s):  
Jessica C.H. Chen ◽  
Harue J. Marsden ◽  
Timothy B. Edrington

Author(s):  
Nathan Efron ◽  
Lyndon W Jones ◽  
Philip B. Morgan ◽  
Jason J. Nichols

2013 ◽  
Vol 36 (3) ◽  
pp. 146-150 ◽  
Author(s):  
Miguel Romero-Jiménez ◽  
Patricia Flores-Rodríguez
Keyword(s):  

2018 ◽  
Vol 2 (2) ◽  
pp. e14-e21
Author(s):  
Melissa Barnett ◽  
Jonathon Ross ◽  
Blythe Durbin-Johnson

Abstract Objectives: The purpose of this study was to evaluate the performance (i.e. vision, comfort and fit) of spherical and front-surface toric scleral lenses in subjects with regular, healthy corneas. Methods: Scleral lenses were fitin the eyes (n = 16) of healthy subjects (n = 9) with regular corneas, absent of pathology, and studied using an observational, multi-visit design. Lens fit was objectively evaluatedby an experienced practitioner.Following 1 month of successful lens wear, participants completedsubjective satisfaction surveys regarding the scleral lens wearing experience. Results:  According to participant surveys, scleral lenses were subjectively preferred over soft toric or gas permeable contact lenses in 88% of eyes, including in all eyes fit with a front-surface toric scleral lens (n = 3). Seventy-five percent (75%) of eyes achieved visual acuity of 0.1 logMAR or better, while all eyes with prior spectacle wear achieved visual acuity with a scleral lens within 1 Snellen line of spectacle correction. Seventy-five percent (75%) of eyes achieved good subjective comfort with a scleral lens. No participants reported poor subjective vision and/or comfort. Conclusions:  Our findings suggest that subjects preferred the performance of a scleral lens (spherical or front-surface toric) compared to a soft toric or gas permeable contact lens. Moreover, scleral lenses may provide a viable, alternative contact lens modality option for patients considering discontinuation of traditional soft toric and/or rigid contact lens wear; so long as the factors associated with hypoxia remain minimized. Key Words:  scleral lens; scleral contact lens; front-surface toric scleral lens; lens performance; normal eyes; healthy eyes


Sign in / Sign up

Export Citation Format

Share Document