contact lenses
Recently Published Documents


TOTAL DOCUMENTS

5293
(FIVE YEARS 938)

H-INDEX

77
(FIVE YEARS 12)

F1000Research ◽  
2022 ◽  
Vol 11 ◽  
pp. 6
Author(s):  
Preetam Kumar ◽  
Karen G. Carrasquillo ◽  
Simmy Chaudhary ◽  
Sayan Basu

Background: While scleral lens practise has improved over the years due to factors such as availability of lenses with better materials and designs as well as experience of practitioners, a lack of objectivity appears to remain in terms of assessment of scleral lens fitting. This prospective observational work aimed to achieve standardization on this front through proposing a grading system for scleral lens fitting. Methods: After application of prosthetic replacement of ocular surface ecosystem (PROSE) devices on the participants’ eyes, four fundamental components for understanding scleral lens fitting such as central and limbal corneal clearance, mid-haptic compression, and alignment of lens edge over anterior sclera were assessed through a series of slit-lamp biomicroscopy imaging as well as with anterior segment optical coherence tomography. FitConnect® was used to modify the device parameters to simulate different grading patterns on the proposed scale. Serial imaging was done for all the different lenses to compose the grading scale. Results: A clinically relevant grading scale was constructed that pictorially demonstrated grades for the different aspect of scleral lens fitting. The grades were conveniently scaled within three categories: “optimal”, “acceptable” and “not acceptable”. Conclusion: The gradation of scleral lens fitting parameters would take a step towards objectifying the assessment patterns in practise. This will also help reducing the gap between a novice and an experienced practitioner in terms of understanding of scleral lens fitting.


2022 ◽  
Vol 58 (4) ◽  
pp. 55-64
Author(s):  
Silvia Salavastru ◽  
Irina Andreea Niagu ◽  
Luana Andrei Macovei ◽  
Lucretia Anghel ◽  
Nicolae Sarbu ◽  
...  

Ophthalmic treatments using contact lenses are now used by more and more specialists around the world. Improving contact lens (CL) materials is a condition that is constantly evolving. Contact lens materials are usually composed of polymer hydrogel or silicone hydrogel. The materials used for night contact lenses are gas permeable and they gradual flatten the center of the cornea which decreases the progression of myopia or myopic astigmatism. The aim of this study is to identify, in correlation with the chemical interactions between structural components of contact lenses and their biocompatibility with the surface layer and microtopography of the cornea or sclera, different incidents that occur in patients who have used rigid gas permeable contact lenses. The study was performed on a group of 10 patients who had a follow-up period between 4 and 6 years, who presented regularly for eye examinations. The following clinical parameters were analyzed: ocular refraction before and after wearing night contact lenses, types of contact lens materials, appearance of corneal topography, biomicroscopic examination of the anterior segment of the eye, keratometry, ocular comfort, as well as other incidents regarding this type of lenses. Difficulties caused by wearing contact lenses at night arose due to poor hygiene and maintenance in two cases or due to interruption of lens wear in one case.


Author(s):  
Wan-Hsin Chang ◽  
Pei-Yi Liu ◽  
Dai-En Lin ◽  
Yuan-Ting Jiang ◽  
Chien-Ju Lu ◽  
...  

Polymers ◽  
2022 ◽  
Vol 14 (1) ◽  
pp. 185
Author(s):  
Hamed Hosseinian ◽  
Samira Hosseini ◽  
Sergio O. Martinez-Chapa ◽  
Mazhar Sher

In recent years, wearable contact lenses for medical applications have attracted significant attention, as they enable continuous real-time recording of physiological information via active and noninvasive measurements. These devices play a vital role in continuous monitoring of intraocular pressure (IOP), noninvasive glucose monitoring in diabetes patients, drug delivery for the treatment of ocular illnesses, and colorblindness treatment. In specific, this class of medical devices is rapidly advancing in the area of drug loading and ocular drug release through incorporation of electrospun fibers. The electrospun fiber matrices offer a high surface area, controlled morphology, wettability, biocompatibility, and tunable porosity, which are highly desirable for controlled drug release. This article provides an overview of the advances of contact lens devices in medical applications with a focus on four main applications of these soft wearable devices: (i) IOP measurement and monitoring, (ii) glucose detection, (iii) ocular drug delivery, and (iv) colorblindness treatment. For each category and application, significant challenges and shortcomings of the current devices are thoroughly discussed, and new areas of opportunity are suggested. We also emphasize the role of electrospun fibers, their fabrication methods along with their characteristics, and the integration of diverse fiber types within the structure of the wearable contact lenses for efficient drug loading, in addition to controlled and sustained drug release. This review article also presents relevant statistics on the evolution of medical contact lenses over the last two decades, their strengths, and the future avenues for making the essential transition from clinical trials to real-world applications.


2022 ◽  
Vol 12 (1) ◽  
pp. 431
Author(s):  
Gema Corpus ◽  
David P. Piñero

This pseudo-experimental, prospective, and longitudinal pilot study was conducted to characterize the optical and visual changes occurring in the short-term wear of a hydrophilic contact lens (CL) based on extended focus technology (EDOF). A total of 30 eyes of 15 children (age, 6–16 years) were fitted with the EDOF CL Mylo (Mark’ennovy Care SL), performing an exhaustive follow-up for one month evaluating changes in visual acuity (VA), accommodation, binocularity, ocular aberrometry, visual quality, pupillometry, keratometry and biometry. Far and near VA with the CL improved progressively (p < 0.001), obtaining mean final binocular values of −0.08 ± 0.01 and −0.07 ± 0.01 LogMAR, respectively. There was a mean reduction in the accommodative LAG of 0.30 D (p < 0.001), without associated alterations in the magnitude of the phoria and fusional vergences (p ≥ 0.066). A controlled but statistically significant increase (p ≤ 0.005) of ocular high order aberration (HOA) root mean square (RMS), primary coma RMS, primary spherical aberration Zernike term and secondary astigmatism RMS was found with the CL wear. In conclusion, the EDOF CL evaluated provides adequate visual acuity and quality, with associated increased of several HOAs and a trend to reduction in the accommodative LAG that should be confirmed in future studies.


Antibiotics ◽  
2022 ◽  
Vol 11 (1) ◽  
pp. 58
Author(s):  
Parthasarathi Kalaiselvan ◽  
Debarun Dutta ◽  
Nagaraju Konda ◽  
Pravin Krishna Vaddavalli ◽  
Savitri Sharma ◽  
...  

(1) Purpose: This study aimed to investigate the effects of Mel4 antimicrobial contact lenses (MACL) on the ocular surface and comfort during extended wear. (2) Methods: A prospective, randomised, double-masked, contralateral clinical trial was conducted with 176 subjects to evaluate the biocompatibility of contralateral wear of MACL. The wearing modality was 14-day extended lens wear for three months. The participants were assessed at lens dispensing, after one night, two weeks, one month and three months of extended wear and one month after study completion. (3) Results: There were no significant differences (p > 0.05) in ocular redness or palpebral roughness between Mel4 and control eyes at any of the study visits. There was no significant difference (p > 0.05) in corneal staining between Mel4 and control eyes. There were no significant differences in front surface wettability or deposits or back surface debris (p > 0.05). No statistically significant differences (p > 0.05) were found in comfort, dryness, CLDEQ-8 scores lens or edge awareness. There was no evidence for delayed reactions on the ocular surface after cessation of lens wear. (4) Conclusion: The novel MACLs showed similar comfort to control lenses and were biocompatible during extended wear. Thus, these lenses were compatible with the ocular surface.


2022 ◽  
Vol Volume 16 ◽  
pp. 51-62
Author(s):  
Andrzej Malinowski ◽  
Małgorzata Mrugacz ◽  
Marcin Stopa ◽  
Erita Filipek ◽  
Anna Moniuszko-Malinowska ◽  
...  