scholarly journals The Variations of the Intraocular Pressure Measured by Goldmann Applanation Tonometer, Tono-Pen, iCare Rebound Tonometer, and Pascal Dynamic Contour Tonometer in Patients Having Corneal Edema after Phacoemulsification

2020 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Weerawat Kiddee ◽  
Arunee Tanjana
2019 ◽  
Vol 2019 ◽  
pp. 1-7
Author(s):  
Mahmoud Rateb ◽  
Mahmoud Abdel-Radi ◽  
Zeiad Eldaly ◽  
Mohamed Nagy Elmohamady ◽  
Asaad Noor El Din

Purpose. To evaluate the different IOP readings by Goldmann applanation tonometer (GAT), ICare rebound tonometer, and Tono-Pen in keratoconus patients after MyoRing implantation. To assess the influence of central corneal thickness (CCT) and thinnest corneal location (TCL) on IOP measurements by different tonometers. Setting. Prospective observational study was conducted in two private centers in Egypt from February 2015 to November 2016. Methods. Seventeen eyes of 10 patients suffering from keratoconus and who underwent MyoRing implantation were recruited. All subjects underwent GAT, ICare, and Tono-Pen IOP measurements in random order. Central corneal thickness and thinnest corneal location were assessed by Pentacam. Difference in mean in IOP readings was assessed by T-test. Correlation between each pair of devices was evaluated by Pearson correlation coefficient. The Bland–Altman analysis was used to assess intertonometer agreement. Results. Seventeen eyes (10 patients) were evaluated. The mean IOP reading was 13.9 ± 3.68, 12.41 ± 2.87, and 14.29 ± 1.31 mmHg in GAT, ICare, and Tono-Pen group, respectively. There was a significant difference between IOP readings by GAT/ICare and Tono-Pen/ICare (p value: 0.032 and 0.002, respectively) with no significant difference between GAT/Tono-Pen (p value: 0.554). Mean difference in IOP measurements between GAT/ICare was 1.49 ± 2.61 mmHg, Tono-Pen/ICare was 1.89 ± 2.15 mmHg, and GAT/Tono-Pen was −0.39 ± 2.59 mmHg. There was no significant correlation between the difference in IOP readings among any pair of devices and CCC or TCL. The Bland–Altman analysis showed a reasonable agreement between any pair of tonometers.


2019 ◽  
Vol 28 (2) ◽  
pp. 172-177 ◽  
Author(s):  
Shunsuke Nakakura ◽  
Etsuko Mori ◽  
Yuki Fujio ◽  
Yasuko Fujisawa ◽  
Kanae Matsuya ◽  
...  

2020 ◽  
pp. 112067212092138
Author(s):  
Katri Stoor ◽  
Elina Karvonen ◽  
Pasi Ohtonen ◽  
M Johanna Liinamaa ◽  
Ville Saarela

Purpose The aim of this study was to compare the measurements of intraocular pressure by two tonometers, the Icare rebound tonometer and the Goldmann applanation tonometer, in a randomised screening study. The influence of refraction and central corneal thickness on the measurements was also evaluated. Methods Intraocular pressure was measured with rebound tonometer and Goldmann applanation tonometer in 1266 participants; refraction and central corneal thickness were also determined. One randomised eye of each participant was selected for this report’s analysis. A Bland–Altman plot was used to compare the values obtained with the two devices. Results The correlation between rebound tonometer and Goldmann applanation tonometer was good: the intraclass correlation coefficient (r) between the two methods was 0.735 ( p < 0.001). The mean difference (rebound tonometer–Goldmann applanation tonometer) was 0.11 ± 2.3 mmHg. The difference was not statistically significant (95% confidence interval: 0.11 to 0.13, p = 0.09). With increasing central corneal thickness, not only did intraocular pressure values with both devices increase, but the difference between them also increased. Refraction (spherical equivalent) did not influence intraocular pressure or the rebound tonometer–Goldmann applanation tonometer difference. However, high astigmatism (≥2D) exerted an influence on intraocular pressure values taken with Goldmann applanation tonometer. Conclusion Measurements with rebound tonometer and Goldmann applanation tonometer are relatively uniform although rebound tonometer slightly overestimated intraocular pressure. Both rebound tonometer and Goldmann applanation tonometer and the difference between these devices were affected by central corneal thickness but not by refraction. Higher astigmatism affected Goldmann applanation tonometer more than rebound tonometer. It is concluded that rebound tonometer is a reliable method for measuring intraocular pressure in a population-based screening study.


Diagnosis ◽  
2015 ◽  
Vol 2 (4) ◽  
pp. 227-234 ◽  
Author(s):  
Yifan Li ◽  
Christopher R. Carpenter ◽  
Kathryn Nicholson ◽  
William Ken Milne

AbstractVision health is recognized as a critical unmet need in North America. The ocular morbidity associated with glaucoma results from increased intraocular pressure (IOP) and early detection is crucial for the management of glaucoma. Our objective was to find a diagnostically accurate screening tool for intraocular hypertension that can be used in rural communities. We sought to validate the diagnostic accuracy of the iCare rebound tonometer against the gold standard Perkins applanation tonometer (PAT) in measuring IOP.Patients from two rural communities in Ontario, Canada visiting their optometrists for routine appointments had their IOP measured by a non-contact tonometer (NCT), an iCare rebound tonometer, and a Perkins applanation tonometer (PAT). Values of sensitivity, specificity, and likelihood ratios for a positive and negative result were calculated for the iCare and the NCT.Complete data was collected from 209 patients. Overall, the iCare tonometer had high levels of validity, as compared to the gold standard PAT. The iCare tonometer displayed excellent sensitivity of 98.3% (90–99%, 95% CI) and excellent negative likelihood ratio of 0.024 (0.0088–0.066, 95% CI) which is useful for ruling out intraocular hypertension.The iCare tonometer is a reasonably valid tool for detecting elevated IOP. Its ease of use, simplicity, and accessibility makes it a good screening tool to improve eye health in rural areas.


Author(s):  
Santanu Das ◽  
Nayana Nagesh ◽  
Kiran Kumar L ◽  
Sundeep Shetty

ABSTRACT: AIM-To compare the intraocular pressure (IOP) measured by Non-Contact tonometer (NCT), Rebound tonometer (RBT) and Goldmann Applanation tonometer (GAT) and their correlation with central corneal thickness (CCT), true IOP and corneal curvature. Reliability of each tonometer. METHODS-500 random patients aged 18 years and above were taken up for the study. Patients with anterior and posterior segment pathologies like corneal ulcer, leukoma, staphyloma, corneal lacerations, ectatic corneal conditions, corneal dystrophies, oedema, perforations, acute angle closure glaucoma, retinal detachments, vitreous haemorrhage and unwilling patients were excluded from the study. IOP was recorded using NCT, RBT and GAT after assessing the patient's visual acuity. Following IOP measurement, central corneal thickness (CCT) of each patient was measured using pachymetry. Kvalues were measured using an autorefractometer. All the data were collected and tabulated for statistical analysis to obtain results. RESULTS: The mean CCT in males was 0.5350 mm and in females 0.5340 mm respectively. The mean IOP measured by NCT is 16.43 mm hg whereas the mean IOP measured by GAT is 15.43 mm hg. IOP measured by NCT is significantly higher than the IOP measured by GAT (p<0.001). When NCT and RBT are compared NCT values are significantly higher than that of RBT(p<0.001). Although the mean RBT IOP 15.83 mm hg is higher than the mean GAT IOP of 15.42 mm hg the values are not statistically significant. When correlated with CCT all the tonometers showed significant correlation with GAT showing the strongest correlation. NCT overestimates IOP in normal, thin and thicker corneas when compared to GAT and are statistically significant. RBT also overestimates in the normal and thick corneas when compared to GAT but their values are much closer to GAT values in thinner corneas. The IOP measured by all the 3 tonometers correlated with corrected IOP with NCT showing the best correlation followed by GAT. There was no significant correlation between K and IOP in our study. CONCLUSION-From the present study we can conclude that IOP measured by NCT and RBT is higher than GAT. NCT values are significantly higher than GAT values in thin and normal corneas whereas it overestimates more in thicker corneas. RBT values are significantly higher than that of GAT in normal and thick corneas. All the tonometers show significant correlation with CCT with GAT showing the strongest correlation. So, it is always advisable to measure the corrected IOP for each patient after considering the CCT. Keywords- Non-contact tonometer; Goldmann applanation tonometer; central corneal thickness; intraocular pressure; Rebound tonometer, true IOP, Corneal curvature.  


Sign in / Sign up

Export Citation Format

Share Document