icare rebound tonometer
Recently Published Documents


TOTAL DOCUMENTS

30
(FIVE YEARS 6)

H-INDEX

11
(FIVE YEARS 1)

2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Pei-Yao Chang ◽  
Jia-Kang Wang ◽  
Hsin-Yu Weng ◽  
Shu-Wen Chang

Abstract Cataract surgery leads to a sustained decrease in sitting intraocular pressure (IOP) in patients with angle-closure glaucoma (ACG). The purpose of this study is to evaluate whether cataract surgery can also reduce postural IOP changes. We prospectively examined 106 eyes from 53 patients with narrow angles scheduled for phacoemulsification. IOP was measured in the sitting, supine, and lateral decubitus positions using an ICare rebound tonometer before and 1 week, 1 month, and 3 months postoperatively. The mean baseline IOP in the sitting and lateral decubitus positions was 17.9 ± 4.8 mmHg and 21.43 ± 6.44 mmHg, which significantly reduced to 13.52 ± 3.8 and 17.46 ± 3.62, respectively, 3 month postoperatively (p < 0.001). However, postural IOP change (lateral decubitus minus sitting) at 3 months postoperatively was not significantly different from that at the baseline (3.17 ± 2.63 vs. 3.53 ± 3.38 mmHg, p = 0.85). Postural IOP change was not associated with preoperative sitting IOP, anterior chamber depth, axial length, fixed pupil, or presence of glaucomatous optic neuropathy. Patients with higher preoperative IOP exhibited greater IOP reduction after cataract surgery in every posture (p < 0.0001). In conclusion, cataract surgery reduces IOP in all postures among patients with ACG; however, it does not reduce the magnitude of postural IOP change.


2019 ◽  
Vol 2019 ◽  
pp. 1-7
Author(s):  
Mahmoud Rateb ◽  
Mahmoud Abdel-Radi ◽  
Zeiad Eldaly ◽  
Mohamed Nagy Elmohamady ◽  
Asaad Noor El Din

Purpose. To evaluate the different IOP readings by Goldmann applanation tonometer (GAT), ICare rebound tonometer, and Tono-Pen in keratoconus patients after MyoRing implantation. To assess the influence of central corneal thickness (CCT) and thinnest corneal location (TCL) on IOP measurements by different tonometers. Setting. Prospective observational study was conducted in two private centers in Egypt from February 2015 to November 2016. Methods. Seventeen eyes of 10 patients suffering from keratoconus and who underwent MyoRing implantation were recruited. All subjects underwent GAT, ICare, and Tono-Pen IOP measurements in random order. Central corneal thickness and thinnest corneal location were assessed by Pentacam. Difference in mean in IOP readings was assessed by T-test. Correlation between each pair of devices was evaluated by Pearson correlation coefficient. The Bland–Altman analysis was used to assess intertonometer agreement. Results. Seventeen eyes (10 patients) were evaluated. The mean IOP reading was 13.9 ± 3.68, 12.41 ± 2.87, and 14.29 ± 1.31 mmHg in GAT, ICare, and Tono-Pen group, respectively. There was a significant difference between IOP readings by GAT/ICare and Tono-Pen/ICare (p value: 0.032 and 0.002, respectively) with no significant difference between GAT/Tono-Pen (p value: 0.554). Mean difference in IOP measurements between GAT/ICare was 1.49 ± 2.61 mmHg, Tono-Pen/ICare was 1.89 ± 2.15 mmHg, and GAT/Tono-Pen was −0.39 ± 2.59 mmHg. There was no significant correlation between the difference in IOP readings among any pair of devices and CCC or TCL. The Bland–Altman analysis showed a reasonable agreement between any pair of tonometers.


2016 ◽  
Vol 100 (2) ◽  
pp. 179-183 ◽  
Author(s):  
Safal Khanal ◽  
Meredith Walton ◽  
Pinakin Gunvant Davey

Diagnosis ◽  
2015 ◽  
Vol 2 (4) ◽  
pp. 227-234 ◽  
Author(s):  
Yifan Li ◽  
Christopher R. Carpenter ◽  
Kathryn Nicholson ◽  
William Ken Milne

AbstractVision health is recognized as a critical unmet need in North America. The ocular morbidity associated with glaucoma results from increased intraocular pressure (IOP) and early detection is crucial for the management of glaucoma. Our objective was to find a diagnostically accurate screening tool for intraocular hypertension that can be used in rural communities. We sought to validate the diagnostic accuracy of the iCare rebound tonometer against the gold standard Perkins applanation tonometer (PAT) in measuring IOP.Patients from two rural communities in Ontario, Canada visiting their optometrists for routine appointments had their IOP measured by a non-contact tonometer (NCT), an iCare rebound tonometer, and a Perkins applanation tonometer (PAT). Values of sensitivity, specificity, and likelihood ratios for a positive and negative result were calculated for the iCare and the NCT.Complete data was collected from 209 patients. Overall, the iCare tonometer had high levels of validity, as compared to the gold standard PAT. The iCare tonometer displayed excellent sensitivity of 98.3% (90–99%, 95% CI) and excellent negative likelihood ratio of 0.024 (0.0088–0.066, 95% CI) which is useful for ruling out intraocular hypertension.The iCare tonometer is a reasonably valid tool for detecting elevated IOP. Its ease of use, simplicity, and accessibility makes it a good screening tool to improve eye health in rural areas.