Effect of worst case multiple partial-band noise and tone jammers on coded FH/SSMA systems

1990 ◽  
Vol 8 (4) ◽  
pp. 613-627 ◽  
Author(s):  
E. Geraniotis
Keyword(s):  
Author(s):  
J.D. Geller ◽  
C.R. Herrington

The minimum magnification for which an image can be acquired is determined by the design and implementation of the electron optical column and the scanning and display electronics. It is also a function of the working distance and, possibly, the accelerating voltage. For secondary and backscattered electron images there are usually no other limiting factors. However, for x-ray maps there are further considerations. The energy-dispersive x-ray spectrometers (EDS) have a much larger solid angle of detection that for WDS. They also do not suffer from Bragg’s Law focusing effects which limit the angular range and focusing distance from the diffracting crystal. In practical terms EDS maps can be acquired at the lowest magnification of the SEM, assuming the collimator does not cutoff the x-ray signal. For WDS the focusing properties of the crystal limits the angular range of acceptance of the incident x-radiation. The range is dependent upon the 2d spacing of the crystal, with the acceptance angle increasing with 2d spacing. The natural line width of the x-ray also plays a role. For the metal layered crystals used to diffract soft x-rays, such as Be - O, the minimum magnification is approximately 100X. In the worst case, for the LEF crystal which diffracts Ti - Zn, ˜1000X is the minimum.


1973 ◽  
Vol 16 (2) ◽  
pp. 267-270 ◽  
Author(s):  
John H. Mills ◽  
Seija A. Talo ◽  
Gloria S. Gordon

Groups of monaural chinchillas trained in behavioral audiometry were exposed in a diffuse sound field to an octave-band noise centered at 4.0 k Hz. The growth of temporary threshold shift (TTS) at 5.7 k Hz from zero to an asymptote (TTS ∞ ) required about 24 hours, and the growth of TTS at 5.7 k Hz from an asymptote to a higher asymptote, about 12–24 hours. TTS ∞ can be described by the equation TTS ∞ = 1.6(SPL-A) where A = 47. These results are consistent with those previously reported in this journal by Carder and Miller and Mills and Talo. Whereas the decay of TTS ∞ to zero required about three days, the decay of TTS ∞ to a lower TTS ∞ required about three to seven days. The decay of TTS ∞ in noise, therefore, appears to require slightly more time than the decay of TTS ∞ in the quiet. However, for a given level of noise, the magnitude of TTS ∞ is the same regardless of whether the TTS asymptote is approached from zero, from a lower asymptote, or from a higher asymptote.


2008 ◽  
Author(s):  
Sonia Savelli ◽  
Susan Joslyn ◽  
Limor Nadav-Greenberg ◽  
Queena Chen

Sign in / Sign up

Export Citation Format

Share Document