Stabilization Control of Power System with Large-Scale Wind Farm by HVDC Interconnection Line

Author(s):  
Ayaka Nakamura ◽  
Atsushi Umemura ◽  
Rion Takahashi ◽  
Junji Tamura ◽  
Yoshiharu Matsumura ◽  
...  
2020 ◽  
Vol 140 (6) ◽  
pp. 531-538
Author(s):  
Kotaro Nagaushi ◽  
Atsushi Umemura ◽  
Rion Takahashi ◽  
Junji Tamura ◽  
Atsushi Sakahara ◽  
...  

2013 ◽  
Vol 448-453 ◽  
pp. 2535-2539
Author(s):  
Jun Cheng ◽  
Qiang Yang ◽  
Tao Zhu ◽  
Ai Meng Wang ◽  
Xue Feng Hu ◽  
...  

With the scale of the wind farm growing fast, its impact on the power system has become increasingly apparent. So the research has a significant meaning on the characteristics of dynamic stability of the power system which contains wind farms, and the stable operation of the large area interconnected power grid. In this paper it realized the application of the double-fed wind turbine grid model by using power system analysis software PSD-BPA. The analysis of the generator power Angle curve which indicate the state after the failure of N-1 shows as follows: with the wind farms integration on the grid, the damping ratio is decreased slightly but little change after the system failure of N-1, which is still live up to the standard of grid stability.


2013 ◽  
Vol 765-767 ◽  
pp. 2579-2585
Author(s):  
Min Jing Yang ◽  
Yan Li ◽  
Jin Yu Wen ◽  
Chun Fang Liu ◽  
Min Jie Zhu ◽  
...  

The high penetration of doubly-fed induction generators (DFIGs) entails a change in dynamics and operational characteristics of the power system, thus this paper investigates the small signal stability of the large-scale wind farm with DFIGs. The GE 1.5MW DFIG is modeled in power system analysis software package (PSASP), and a large-scale wind farm with DFIGs is established. Then, the two-area test system with four generators is applied to assess the effect of the large wind farm on power system inter-area oscillatory mode in which the penetration and the installation site of the wind farm are considered. Finally, the simulation results indicate that abundant penetration of DFIG-based wind power will improve the inter-area oscillatory, and the integration of wind farms with DFIGs in the receiving area makes the inter-area mode highly damped.


2013 ◽  
Vol 380-384 ◽  
pp. 3051-3056 ◽  
Author(s):  
Xiao Dan Wu ◽  
Wen Ying Liu

In this paper, starting from the active network loss formulas and wind characteristics, it is pointed out the reactive power loss and reactive flow is the major impact of wind power integration on power system loss. The reactive power loss formulas of box-type transformer, main step-up transformer, wind farm collector line and connecting grid line are analyzed. Next the reactive power loss of transformer and transmission line is described in detail. Then put forward the loss reduction measures that installing SVC on the low voltage side of the main step-up transformer and making the doubly-fed wind generators send out some reactive power at an allowed power factor. Use the case of Gansu Qiaodong wind farm to verify the effectiveness of the proposed measures.