Statistical methods application in signals spectral classification for power quality estimation in power transmission lines with fast changing loads

Author(s):  
Pavel V. Morozov ◽  
Yury V. Morozov
2019 ◽  
Vol 114 ◽  
pp. 04001
Author(s):  
Yu.N. Bulatov ◽  
A.V. Kryukov ◽  
A.V. Cherepanov

The increase in the trains weight and their operation speeds leads to considerable growth of abrupt-variable, non-linear and one-phase traction loads. This, in its own turn, leads to significant deviations, unsymmetry and voltage harmonic distortions in 110-220 kV mains adjacent to traction substations of AC railroads. Significant deterioration in power quality factors is observed in Siberian and Far East regions where 110-220 kV main power transmission lines are immediately adjacent to Transsib traction substations; in this case, in points with lower levels of short circuit power, power quality factors exceed by far the permissible levels. The articles provides the results of studies aimed at solution of power quality enhancement is-sues for mains adjacent to traction substations of Trans-Siberian Railway. To enhance power quality in mains supplying traction substations, smart grid technologies can be used together with multiagent control systems. Technical solutions, based on the results obtained, are proposed that allow to bring the power quality factors to the regulatory values. Due to a big investments amount, an implementation of tar-get program is needed to resolve the large-scale issue of enhancing power quality in mains adjacent to traction substations of AC railroads.


2016 ◽  
Vol 2016 (4) ◽  
pp. 8-10 ◽  
Author(s):  
B.I. Kuznetsov ◽  
◽  
A.N. Turenko ◽  
T.B. Nikitina ◽  
A.V. Voloshko ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1561
Author(s):  
Hao Chen ◽  
Zhongnan Qian ◽  
Chengyin Liu ◽  
Jiande Wu ◽  
Wuhua Li ◽  
...  

Current measurement is a key part of the monitoring system for power transmission lines. Compared with the conventional current sensor, the distributed, self-powered and contactless current sensor has great advantages of safety and reliability. By integrating the current sensing function and the energy harvesting function of current transformer (CT), a time-multiplexed self-powered wireless sensor that can measure the power transmission line current is presented in this paper. Two operating modes of CT, including current sensing mode and energy harvesting mode, are analyzed in detail. Through the design of mode-switching circuit, harvesting circuit and measurement circuit are isolated using only one CT secondary coil, which eliminates the interference between energy harvesting and current measurement. Thus, the accurate measurement in the current sensing mode and the maximum energy collection in the energy harvesting mode are both realized, all of which simplify the online power transmission line monitoring. The designed time-multiplexed working mode allows the sensor to work at a lower transmission line current, at the expense of a lower working frequency. Finally, the proposed sensor is verified by experiments.


IEEE Access ◽  
2021 ◽  
pp. 1-1
Author(s):  
Vedanta Pradhan ◽  
O. D. Naidu ◽  
Sinisa Zubic ◽  
Patrick Cost

Author(s):  
Ronaldo F. R. Pereira ◽  
Felipe P. Albuquerque ◽  
Luisa H. B. Liboni ◽  
Eduardo C. M. Costa ◽  
Mauricio C. de Oliveira

Sign in / Sign up

Export Citation Format

Share Document