The use of low-emission combustion techniques in pulverized coal-fired (PC) boilers are usually associated with the formation of a reduced-gas atmosphere near evaporator walls. This increases the risk of high temperature (low oxygen) corrosion processes in coal-fired boilers. The identification of the dynamics and the locations of these processes, and minimizing negative consequences are essential for power plant operation. This paper presents the diagnostic system for determining corrosion risks, based on continuous measurements of flue gas composition in the boundary layer of the combustion chamber, and artificial intelligence techniques. Experience from the implementation of these measurements on the OP-230 hard coal-fired boiler, to identify the corrosion hazard of one of the evaporator walls, has been thoroughly described. The results obtained indicate that the continuous controlling of the concentrations of O2 and CO near the water wall, in combination with the use of neural networks, allows for the forecasting of the corrosion rate of the evaporator. The correlation between flue gas composition and corrosion rate has been demonstrated. At the same time, the analysis of the possibilities of significantly simplifying the measurement system by using neural networks was carried out.