Adaptive Robotic Arm Control using Artificial Neural Network

Author(s):  
Dino Dominic Ligutan ◽  
Alexander C. Abad ◽  
Elmer P. Dadios
Author(s):  
Albert Ashraf Alphonse ◽  
Ahmed Ashraf Abbas ◽  
Amr Medhat Fathy ◽  
Nada Saif Elsayed ◽  
Hossam Hassan Ammar ◽  
...  

2016 ◽  
Vol 2016 ◽  
pp. 1-10 ◽  
Author(s):  
Ahmed R. J. Almusawi ◽  
L. Canan Dülger ◽  
Sadettin Kapucu

This paper presents a novel inverse kinematics solution for robotic arm based on artificial neural network (ANN) architecture. The motion of robotic arm is controlled by the kinematics of ANN. A new artificial neural network approach for inverse kinematics is proposed. The novelty of the proposed ANN is the inclusion of the feedback of current joint angles configuration of robotic arm as well as the desired position and orientation in the input pattern of neural network, while the traditional ANN has only the desired position and orientation of the end effector in the input pattern of neural network. In this paper, a six DOF Denso robotic arm with a gripper is controlled by ANN. The comprehensive experimental results proved the applicability and the efficiency of the proposed approach in robotic motion control. The inclusion of current configuration of joint angles in ANN significantly increased the accuracy of ANN estimation of the joint angles output. The new controller design has advantages over the existing techniques for minimizing the position error in unconventional tasks and increasing the accuracy of ANN in estimation of robot’s joint angles.


2021 ◽  
Vol 15 (2) ◽  
pp. 42
Author(s):  
Adi Abimanyu, M.Eng ◽  
Misbah Habib Putra ◽  
Muhtadan Muhtadan

Brachytherapy is a cancer treatment that uses radioactive sources with temporary or permanent implantation in cancer tissue. The theraphy uses a radioactive Ir-192 source wrapped in a stainless steel capsule with a diameter of 0.5 mm and a length of 4 mm. The Center for Radioisotopes and Radiopharmaceutical Technology applies a remote manipulator to manufacture microcapsules, which affects the accuracy and risks of the radiation received by the operator. Therefore, to solve this problem, it is necessary to design a 5 DoF robotic arm based on artificial neural networks as a radioactive source transfer tool to improve the precision and safety of operators in preparing the radioactive sources. In developing the 5 DoF robotic arm control system, the NImyRIO was employed, which can control the servo motor, relay pump and valve reality, image processing, and inverse kinematic. The inverse kinematic uses the neural network method with a forward kinematic validation. The inverse kinematic test obtains the RMSE value of 2.78932 for x, 5.05205 for y, and 12.641 for z in the inverse kinematic test of artificial neural networks. Therefore, the inverse kinematic accuracy of the artificial neural network needs to be redeveloped.


2000 ◽  
Vol 25 (4) ◽  
pp. 325-325
Author(s):  
J.L.N. Roodenburg ◽  
H.J. Van Staveren ◽  
N.L.P. Van Veen ◽  
O.C. Speelman ◽  
J.M. Nauta ◽  
...  

2004 ◽  
Vol 171 (4S) ◽  
pp. 502-503
Author(s):  
Mohamed A. Gomha ◽  
Khaled Z. Sheir ◽  
Saeed Showky ◽  
Khaled Madbouly ◽  
Emad Elsobky ◽  
...  

1998 ◽  
Vol 49 (7) ◽  
pp. 717-722 ◽  
Author(s):  
M C M de Carvalho ◽  
M S Dougherty ◽  
A S Fowkes ◽  
M R Wardman

Sign in / Sign up

Export Citation Format

Share Document