Live Line Measuring the Impedance Parameters of Transmission Lines Based on Interference Sources

Author(s):  
Chengqian Xiao ◽  
Zhijian Hu
2022 ◽  
Vol 12 (2) ◽  
pp. 875
Author(s):  
Nan Zhang ◽  
Xiaolong Wang ◽  
Chunxi Bao ◽  
Bin Wu ◽  
Chun-Ping Chen ◽  
...  

In this paper, a novel synthetization approach is proposed for filter-integrated wideband impedance transformers (ITs). The original topology consists of N cascaded coupled line sections (CLSs) with 2N characteristic impedance parameters. By analyzing these characteristic impedances, a Chebyshev response can be derived to consume N + 2 design conditions. To optimize the left N − 2 variable parameters, CLSs were newly substituted by transmission lines (TLs) to consume the remaining variable parameters and simplify the circuit topology. Therefore, there are totally 2N − N − 2 substituting possibilities. To verify the proposed approach, 25 cases are listed under the condition of N = 5, and 7 selected cases are compared and discussed in detail. Finally, a 75–50 Ω IT with 100% fractional bandwidth and 20 dB bandpass return loss (RL) is designed and fabricated. The measured results meet the circuit simulation and the EM simulation accurately.