Development of a logical rule-based islanding detection method for distributed resources

Author(s):  
Sung-Il Jang ◽  
Kwang-Ho Kim
Author(s):  
J Rajesh Reddy ◽  
A Pandian ◽  
R Dhanasekaran ◽  
Rami Reddy Ch ◽  
B Prasanna Lakshmi ◽  
...  

Grid integration of non conventional energy resources is increasing in day to day life to supply the global energy utilization requirement. The major problem with such integrated Distributed Generation (DG) is islanding. The islanding is originated in the integrated system when a part of the power system is disconnected from the grid and continue to feed the local load. The islanding is not safe to field persons and equipment. As per IEEE 1547 standards, the islanding should be detected within 2 seconds with the equipments associated with it. In this paper, a new islanding detection method is proposed with fuzzy rule based approach with inputs as the change in frequency and power. This method classifies the islanding and non islanding events efficiently compared to other passive methods. The simulations are carried on Matlab/ Simulink 2018b environment.


2017 ◽  
Vol 8 (4) ◽  
pp. 1821-1830 ◽  
Author(s):  
Qinfei Sun ◽  
Josep M. Guerrero ◽  
Tianjun Jing ◽  
Juan C. Vasquez ◽  
Rengang Yang

2015 ◽  
Vol 2015 ◽  
pp. 1-11 ◽  
Author(s):  
Manop Yingram ◽  
Suttichai Premrudeepreechacharn

The mainly used local islanding detection methods may be classified as active and passive methods. Passive methods do not perturb the system but they have larger nondetection zones, whereas active methods have smaller nondetection zones but they perturb the system. In this paper, a new hybrid method is proposed to solve this problem. An over/undervoltage (passive method) has been used to initiate an undervoltage shift (active method), which changes the undervoltage shift of inverter, when the passive method cannot have a clear discrimination between islanding and other events in the system. Simulation results on MATLAB/SIMULINK show that over/undervoltage and undervoltage shifts of hybrid islanding detection method are very effective because they can determine anti-islanding condition very fast.ΔP/P>38.41% could determine anti-islanding condition within 0.04 s;ΔP/P<-24.39% could determine anti-islanding condition within 0.04 s;-24.39%≤ΔP/P≤ 38.41% could determine anti-islanding condition within 0.08 s. This method perturbed the system, only in the case of-24.39% ≤ΔP/P ≤38.41% at which the control system of inverter injected a signal of undervoltage shift as necessary to check if the occurrence condition was an islanding condition or not.


Solar Energy ◽  
2013 ◽  
Vol 97 ◽  
pp. 155-167 ◽  
Author(s):  
Ku Nurul Edhura Ku Ahmad ◽  
Nasrudin Abd Rahim ◽  
Jeyraj Selvaraj ◽  
Ahmad Rivai ◽  
Krismadinata Chaniago