Identification of the Magnetic Model of Permanent-Magnet Synchronous Machines Using DC-Biased Low-Frequency AC Signal Injection

2015 ◽  
Vol 51 (4) ◽  
pp. 3208-3215 ◽  
Author(s):  
Shafiq Ahmed Odhano ◽  
Radu Bojoi ◽  
Stefan George Rosu ◽  
Alberto Tenconi
Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 592
Author(s):  
Maria Martinez ◽  
David Reigosa ◽  
Daniel Fernandez ◽  
Fernando Briz

Torque estimation in permanent magnet synchronous machines and synchronous reluctance machines is required in many applications. Torque produced by a permanent magnet synchronous machine depends on the permanent magnets’ flux and d q -axes inductances, whereas torque in synchronous reluctance machines depends on the d q -axes inductances. Consequently, precise knowledge of these parameters is required for proper torque estimation. The use of high frequency signal both for permanent magnets’ flux and d q -axes inductances estimation has been recently shown to be a viable option. This paper reviews the physical principles, implementation and performance of high-frequency signal injection based torque estimation for permanent magnet synchronous machines and synchronous reluctance machines.