Load Flow Analysis of the Nigerian Transmission Grid Using DIgSILENT PowerFactory

Author(s):  
Omowumi Grace Olasunkanmi ◽  
Zhida Deng ◽  
Grazia Todeschini
2018 ◽  
Vol 8 (3) ◽  
pp. 2963-2968 ◽  
Author(s):  
M. L. Tuballa ◽  
M. L. S. Abundo

When a new power source connects to the distribution or transmission grid, an assessment of its impact is necessary. Technical studies must assess the possible effects of a proposed expansion, reinforcement or modification to evaluate the possible incidents that may occur. Typically, the calculations or analyses done are load flow, short-circuit, and transient stability. The possible renewable energy (RE) sources are determined first. The details of the existing electrical system, including the specifications for the elements used, are obtained and logical assumptions are utilized for those that are not known. The load flow analysis in the considered case revealed that the RE presence reduces diesel generation. The 119 kW PV array and the 54 kW tidal turbine displace most diesel generation: 22% of Gen 4 and 21.8% of Gen 5. The diesel-solar system brought the diesel generation down by 20.05% of Gen 4 and 20% of Gen 5. The diesel-tidal combination lessened the diesel generation by 1.92% of Gen 4 and 1.83% of Gen 5. Short-circuit analysis alerts indicating the operating percentages of the circuit breakers that are beyond their interrupting ratings are presented. The transient stability analysis depicts that RE sources affect the existing system and appear to be putting in more stress. The studied systems are not transient-stable based on the results. While it is relatively simple to plan to put up renewables in remote island systems, there are many factors to consider such as the possible impacts of the RE sources.


Author(s):  
Shenghu Li

The induction generators (IGs) are basic to wind energy conversion. They produce the active power and consume the reactive power, with the voltage characteristics fragile compared with that of the synchronous generators and doubly-fed IGs. In the stressed system states, they may intensify var imbalance, yielding undesirable operation of zone 3 impedance relays.In this paper, the operation characteristics of the zone 3 relays in the wind power systems is studied. With the theoretical and load flow analysis, it is proved that the equivalent impedance of the IGs lies in the 2nd quadrature, possibly seen as the backward faults by the mho relays, i.e. the apparent impedance enters into the protection region from the left side. The undesirable operation may be caused by more wind power, larger load, less var compensation, and larger torque angle.


2021 ◽  
pp. 177-196
Author(s):  
P. Sivaraman ◽  
C. Sharmeela ◽  
S. Elango

Sign in / Sign up

Export Citation Format

Share Document