scholarly journals Arterial to end-tidal carbon dioxide difference in children undergoing mechanical ventilation of the lungs during general anaesthesia

Anaesthesia ◽  
2017 ◽  
Vol 72 (11) ◽  
pp. 1357-1364 ◽  
Author(s):  
C. Onodi ◽  
P. K. Bühler ◽  
J. Thomas ◽  
A. Schmitz ◽  
M. Weiss
Critical Care ◽  
2022 ◽  
Vol 26 (1) ◽  
Author(s):  
Haijun Huang ◽  
Chenxia Wu ◽  
Qinkang Shen ◽  
Yixin Fang ◽  
Hua Xu

Abstract Background The ability of end-tidal carbon dioxide (ΔEtCO2) for predicting fluid responsiveness has been extensively studied with conflicting results. This meta-analysis aimed to explore the value of ΔEtCO2 for predicting fluid responsiveness during the passive leg raising (PLR) test in patients with mechanical ventilation. Methods PubMed, Embase, and Cochrane Central Register of Controlled Trials were searched up to November 2021. The diagnostic odds ratio (DOR), sensitivity, and specificity were calculated. The summary receiver operating characteristic curve was estimated, and the area under the curve (AUROC) was calculated. Q test and I2 statistics were used for study heterogeneity and publication bias was assessed by Deeks’ funnel plot asymmetry test. We performed meta-regression analysis for heterogeneity exploration and sensitivity analysis for the publication bias. Results Overall, six studies including 298 patients were included in this review, of whom 149 (50%) were fluid responsive. The cutoff values of ΔEtCO2 in four studies was 5%, one was 5.8% and the other one was an absolute increase 2 mmHg. Heterogeneity between studies was assessed with an overall Q = 4.098, I2 = 51%, and P = 0.064. The pooled sensitivity and specificity for the overall population were 0.79 (95% CI 0.72–0.85) and 0.90 (95% CI 0.77–0.96), respectively. The DOR was 35 (95% CI 12–107). The pooled AUROC was 0.81 (95% CI 0.77–0.84). On meta-regression analysis, the number of patients was sources of heterogeneity. The sensitivity analysis showed that the pooled DOR ranged from 21 to 140 and the pooled AUC ranged from 0.92 to 0.96 when one study was omitted. Conclusions Though the limited number of studies included and study heterogeneity, our meta-analysis confirmed that the ΔEtCO2 performed moderately in predicting fluid responsiveness during the PLR test in patients with mechanical ventilation.


2021 ◽  
Author(s):  
Haijun Huang ◽  
Chenxia Wu ◽  
Qinkang Shen ◽  
Yixin Fang ◽  
Hua Xu

Abstract Background: The variation of end-tidal carbon dioxide(ΔEtCO2) has have been extensively studied with respect to its value in predicting fluid responsiveness, but the results are conflicting. This meta-analysis aimed to explore the value of ΔEtCO2 for predicting fluid responsiveness during the passive leg raising(PLR) test in patients with mechanical ventilation. Methods: PubMed, Embase, and Cochrane Central Register of Controlled Trials were searched up to November 2021. The diagnostic odds ratio (DOR), sensitivity, and specificity were calculated. The summary receiver operating characteristic curve was estimated, and the area under the curve (AUROC) was calculated. We performed meta-regression analysis for heterogeneity exploration and sensitivity analysis for the publication bias.Results: Overall, 298 patients were included in this review, of whom 149 (50%) were fluid responsive. The cutoff values of ΔEtCO2 varied across studies, ranging from 5% to 5.8% or absolute increase 2mmHg. Heterogeneity between studies was assessed with an overall Q = 4.098, I2 = 51%, and P = 0.064. The pooled sensitivity and specificity for the overall population were 0.79 (95% CI: 0.72–0.85) and 0.90 (95% CI: 0.77–0.96), respectively. The DOR was 35 (95% CI: 12–107) (Fig. 4). The pooled AUROC was 0.81 (95% CI: 0.77–0.84). On meta-regression analysis, the number of patients was sources of heterogeneity. The sensitivity analysis showed that the pooled DOR ranged from 21 to 140 and the pooled AUC ranged from 0.92 to 0.96 when one study was omitted.Conclusions: This study was the first meta-analysis to evaluate the diagnostic accuracy of ΔEtCO2 in predicting fluid responsiveness during PLR test in patients with mechanical ventilation. This study confirmed that the ΔEtCO2 performed well in predicting fluid responsiveness in patients with mechanical ventilation.


Medicine ◽  
2021 ◽  
Vol 100 (33) ◽  
pp. e26973
Author(s):  
Jinrong Wang ◽  
Jianjun Zhang ◽  
Yajing Liu ◽  
Huimian Shang ◽  
Li Peng ◽  
...  

Anaesthesia ◽  
2018 ◽  
Vol 73 (5) ◽  
pp. 647-647
Author(s):  
M. Weiss ◽  
C. Onodi ◽  
P. K. Bühler ◽  
J. Thomas ◽  
A. Schmitz

1989 ◽  
Vol 140 (5) ◽  
pp. 1265-1268 ◽  
Author(s):  
Richard A. Hoffman ◽  
Bruce P. Krieger ◽  
Mordechai R. Kramer ◽  
Sally Segel ◽  
Frank Bizousky ◽  
...  

1996 ◽  
Vol 15 (4) ◽  
pp. 171-176 ◽  
Author(s):  
Cheryl J. Erler ◽  
William F. Rutherford ◽  
Angela Fiege ◽  
David R. Nelson ◽  
Ann Stahl