Conduction System Pacing after Septal Myectomy: Obstruction of Just‐His

Author(s):  
Weeranun D. Bode ◽  
Robert D. Schaller
Author(s):  
Rujie Zheng ◽  
Yingxue Dong ◽  
Shengjie Wu ◽  
Lan Su ◽  
Dongdong Zhao ◽  
...  

2014 ◽  
Vol 17 (5) ◽  
pp. 269
Author(s):  
Shinya Takahashi ◽  
Taiichi Takasaki ◽  
Futoshi Tadehara ◽  
Takahiro Taguchi ◽  
Keijiro Katayama ◽  
...  

An 86-year-old woman presented with chest pain and discomfort. Echocardiography revealed severe aortic valve stenosis and asymmetric septal hypertrophy. Aortic valve replacement and myectomy were performed using a curved knife. The blade was U-shaped in cross-section, and was curved upward along the long axis. Hypertrophic septal myocardium was removed along the long axis of the left ventricle (LV), and a groove for blood flow was constructed. The patient was discharged uneventfully without recurrence of her chest discomfort. Our result suggested that a curved knife is a reasonable option for transaortic septal myectomy in patients with obstructive LV hypertrophy.


2012 ◽  
Vol 15 (5) ◽  
pp. 251
Author(s):  
Changqing Gao ◽  
Chonglei Ren ◽  
Cangsong Xiao ◽  
Yang Wu ◽  
Gang Wang ◽  
...  

<p><b>Background:</b> The purpose of this study was to summarize our experience of extended ventricular septal myectomy in patients with hypertrophic obstructive cardiomyopathy (HOCM).</p><p><b>Methods:</b> Thirty-eight patients (26 men, 12 women) with HOCM underwent extended ventricular septal myectomy. The mean age was 36.3 years (range, 18-64 years). Diagnosis was made by echocardiography. The mean (mean � SE) systolic gradient between the left ventricle (LV) and the aorta was 89.3 � 31.1 mm Hg (range, 50-184 mm Hg) according to echocardiographic assessments before the operations. Moderate or severe systolic anterior motion (SAM) of the anterior leaflet of the mitral valve was found in 38 cases, and mitral regurgitation was present in 29 cases. Extended ventricular septal myectomy was performed in all 38 cases. The results of the surgical procedures were evaluated intraoperatively with transesophageal echocardiography (TEE) and with transthoracic echocardiography (TTE) at 1 to 2 weeks after the operation. All patients were followed up with TTE after their operation.</p><p><b>Results:</b> All patients were discharged without complications. The TEE evaluations showed that the mean systolic gradient between the LV and the aorta decreased from 94.8 � 35.6 mm Hg preoperatively to 13.6 � 10.8 mm Hg postoperatively (<i>P</i> = .0000) and that the mean thickness of the ventricular septum decreased from 28.3 � 7.9 mm to 11.8 � 3.2 mm (<i>P</i> = .0000). Mitral regurgitation and SAM were significantly reduced or eliminated. During the follow-up, all patients promptly became completely asymptomatic or complained of mild effort dyspnea only, and syncope was abolished. TTE examinations showed that the postoperative pressure gradient either remained the same or diminished.</p><p><b>Conclusions:</b> Extended ventricular septal myectomy is mostly an effective method for patients with HOCM, and good surgical exposure and thorough excision of the hypertrophic septum are of paramount importance for a successful surgery.</p>


2018 ◽  
Vol 19 ◽  
pp. e76-00
Author(s):  
G. Saitto ◽  
F. Grimaldi ◽  
A. Varrica ◽  
A. Biondi ◽  
A. Garatti ◽  
...  

2020 ◽  
Vol 5 (04) ◽  
pp. 368-372
Author(s):  
Seema Kale

AbstractVarying kinds of AV blocks can occur in the setting of myocardial ischaemia or due to degeneration of conduction system. Wenckebach AV block can present with typical Wenckebach periodicity or atypical periodicity. A variant of atypical Wenckebach periodicity may present like Mobitz II AV block. This is called Pseudo Mobitz II AV block. As we are aware that Mobitz II AV block is more dangerous and can suddenly convert into complete heart block, it is essential that we should try to differentiate between Mobitz and Pseudo Mobitz II blocks. Infact atypical Wenckebach cycles are quite common at both AV node and his Purkinje system.


Sign in / Sign up

Export Citation Format

Share Document