Non-immediate-reading skin tests and prolonged challenges in non-immediate hypersensitivity to beta-lactams in children

2017 ◽  
Vol 29 (1) ◽  
pp. 84-89 ◽  
Author(s):  
G. Lezmi ◽  
F. Alrowaishdi ◽  
A. Bados-Albiero ◽  
P. Scheinmann ◽  
J. de Blic ◽  
...  
2020 ◽  
Vol 8 (7) ◽  
pp. 2431-2433 ◽  
Author(s):  
Rik Schrijvers ◽  
Bárbara Kong Cardoso ◽  
Jean Luc Bourrain ◽  
Pascal Demoly ◽  
Anca Mirela Chiriac

2018 ◽  
Vol 80 (3) ◽  
pp. 170-172 ◽  
Author(s):  
Marta Tramontana ◽  
Katharina Hansel ◽  
Leonardo Bianchi ◽  
Daniela Agostinelli ◽  
Luca Stingeni

2020 ◽  
pp. 1-9
Author(s):  
Charlotte Gotthard Mortz ◽  
Carsten Bindslev-Jensen

2017 ◽  
Vol 126 (5) ◽  
pp. 834-841 ◽  
Author(s):  
Dominique Laroche ◽  
Pierre Léturgie ◽  
Delphine Mariotte ◽  
Yann Ollivier ◽  
Jean-Luc Hanouz ◽  
...  

Abstract Background Immediate hypersensitivity reactions occurring during anesthesia are classified as allergic when skin tests and mast cell tryptase are positive and as nonallergic when negative results are obtained. Cysteinyl leukotrienes (cysLTs) are potent mediators synthesized by mast cell and eosinophil that induce bronchial constriction. They could play a role in hypersensitivity reactions. Methods cysLT C4, D4, and E4 concentrations were measured by a competition immunoassay in serial plasma samples obtained prospectively from 21 anesthetized controls and retrospectively from 34 patients who reacted at induction of anesthesia (24 with allergic and 10 with nonallergic reactions). Results In controls, the median (interquartile range) cysLT concentration was 0.83 (0.69 to 1.02) μg/l before anesthesia and was unchanged 30 min, 6 h, and 24 h afterward. In the patients with allergic reactions, the values were highly increased 30 to 60 min after the reaction (17.9 [7.8 to 36.0] μg/l), while the patients with nonallergic reactions had less increased values (7.3 [3.0 to 11.5] μg/l). The difference between the three groups was significant (P < 0.0001). Increased values persisted during the 24 h of observation. Concentrations were significantly higher in patients with bronchospasm (P = 0.016). Conclusions cysLTs appear to be an important mediator of allergic and nonallergic immediate hypersensitivity reactions. These findings might open a new field for management of patients with hypersensitivity reactions, especially nonallergic ones.


2022 ◽  
Vol 2 ◽  
Author(s):  
Teodorikez Wilfox Jimenez-Rodriguez ◽  
Francisco Manuel Marco de la Calle ◽  
Inmaculada Lozano-Cubo ◽  
Rosa Ana Montoyo-Anton ◽  
Victor Soriano-Gomis ◽  
...  

Introduction: Phenotype I hypersensitivity reactions are the most commonly reported drug reactions; however, precision medicine has made it possible to characterize new phenotypes. A recent communication proposed the existence of a “converter phenotype,” which would affect patients who present non-immediate hypersensitivity reactions and in subsequent exposures develop immediate hypersensitivity reactions. This study aimed to describe the clinical characteristics of converter phenotype reactions and their evolution during desensitization to chemotherapeutic drugs and monoclonal antibodies.Methods: We retrospectively reviewed our database of patients undergoing desensitization to chemotherapy or biological agents and selected those with a converter phenotype. Demographic and clinical characteristics of the patients, the results of skin tests, tryptase and IL-6 levels, and desensitization outcomes were assessed.Results: Of 116 patients evaluated, 12 (10.3%) were identified as having a converter phenotype. The median interval between drug exposure and reaction was 90.6 h (range 8-288 h). After the conversion, phenotype I was the most frequent (58.3%), followed by cytokine release reactions (33.3%). Fifty-one desensitizations were undertaken and all treatments completed, with 10 (19.6%) breakthrough reactions. No new changes in the phenotype were detected.Conclusions: The symptoms of non-immediate drug hypersensitivity reactions may indicate the need for an early allergological evaluation to assess the risk of future immediate drug reactions. Clinical characteristics, skin test results, and biomarkers can help predict responses to rapid drug desensitization, guiding clinicians on how to optimize therapy delivery while maintaining patient safety.


2011 ◽  
Vol 114 (1) ◽  
pp. 91-97 ◽  
Author(s):  
Dominique Laroche ◽  
Sylvie Chollet-Martin ◽  
Pierre Léturgie ◽  
Laure Malzac ◽  
Marie-Claude Vergnaud ◽  
...  

Background Neuromuscular blocking agents (NMBA) are responsible for most immediate hypersensitivity reactions during anesthesia, as a result of the presence of a quaternary ammonium ion. The aim of this study was to evaluate the diagnostic performance of a commercial immunoglobulin E (IgE) test (quaternary ammonium morphine [QAM]) for diagnosing sensitivity to NMBA. Methods We tested 168 patients exposed to NMBAs during anesthesia. Of those patients, 54 had an uneventful procedure and 114 had immediate hypersensitivity reactions, and 57 patients had positive skin tests to the administered NMBA, whereas 57 had negative skin tests. Specific IgE concentrations determined with the QAM method based on a morphine solid phase were compared with those obtained with a recommended experimental method with a choline solid phase. Results For the QAM test, a 0.35 kUA/l positivity cutoff was chosen from the receiver operating characteristics curve. QAM-specific IgE was found in 84.2% of skin test-positive reactors (80.7% with the recommended method; no significant difference), and binding was inhibited by the culprit NMBA in 80% of cases. The frequency of QAM-specific IgE positivity was significantly higher in skin test-negative reactors (24.6%) than in controls (9.3%), suggesting NMBA sensitivity. Conclusion Sensitivity of the QAM test (84.2%), together with its simplicity and suitability for routine laboratory use, makes it a valuable tool, in conjunction with skin tests, for diagnosing NMBA sensitivity in patients who react after NMBA injection. The QAM test is of particular interest when skin tests are not available or not reliable or give results poorly compatible with mediator release or clinical features.


Author(s):  
Sabela Pérez‐Codesido ◽  
Jean‐Luc Bourrain ◽  
Pascal Demoly ◽  
Anca‐Mirela Chiriac

2015 ◽  
Vol 27 (10) ◽  
pp. 1200-1208 ◽  
Author(s):  
Estelle Fréling ◽  
Laurent Peyrin-Biroulet ◽  
Claire Poreaux ◽  
Alain Morali ◽  
Julie Waton ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document