An Experimental Study on Segmented-Encapsulated Electrode Dielectric-Barrier-Discharge Plasma Actuator for Mapping Ice Formation on a Surface: A Conceptual Analysis

2020 ◽  
Vol 143 (1) ◽  
Author(s):  
F. Rodrigues ◽  
M. Abdollahzadeh ◽  
J. C. Pascoa ◽  
P. J. Oliveira

Abstract A novel design of the dielectric barrier discharge (DBD) actuator/sensor is proposed for mapping the location of icing on a surface. The new design uses segmentation of the embedded electrode of the DBD actuator. Segmented DBD actuator/sensor devices were fabricated and experimentally tested in terms of mechanical, thermal and sensing abilities. The sensing capability of the new actuator was analyzed experimentally. Stationary and dynamic icing tests were conducted and the electrical characteristics of the DBD were measured. A parametric study on the effect of the electrode dimensions on the degree of sensitivity of the device was performed. Experimental results show that by using a segmented configuration it is possible to sense the onset of ice formation and also to detect its location. Furthermore, it is possible to detect the initiation of the melting process and measure the time for the water/ice to be completely expelled from the surface. It is also shown that the segmented actuator has better deicing performance in comparison to the conventional actuators. It is also shown that the thermal and active flow control abilities are not compromised by the segmented configuration and thus this device may perform deicing, ice formation and location detection and active flow control.

Author(s):  
David E. Ashpis ◽  
Douglas R. Thurman

Dielectric Barrier Discharge (DBD) plasma actuators for active flow control in the jet engine need to be tested in the laboratory to characterize their performance at flight operating conditions. DBD plasma actuators generate a wall-jet electronically by creating weakly ionized plasma, therefore their performance is affected by gas discharge properties, which in turn depend on the pressure and temperature at the actuator placement location. Characterization of actuators is initially performed in a laboratory chamber without external flow. It is usually impractical to simultaneously set engine pressures and temperatures in a chamber, and a simplified approach is desired. It is assumed that the plasma discharge depends only on the gas density. Other temperature effects are assumed to be negligible. Therefore, tests can be performed at room temperature with chamber pressure set to yield the same density as in engine operating flight conditions. Engine data was obtained from four generic engine models; 300-, 150-, and 50-Passenger (PAX) aircraft engines, and a military jet-fighter engine. The static and total pressure, temperature, and density distributions along the engine were calculated for sea-level takeoff and altitude cruise, and the chamber pressures needed to test the actuators were calculated. The results show that testing has to be performed over a wide range of pressures from 12.4 to 0.03 atm, depending on the application. For example, if a DBD plasma actuator is to be placed at the compressor exit of a 300 PAX engine, it has to be tested at 12.4 atm for takeoff, and 6 atm for cruise conditions. If it is to be placed at the low-pressure turbine, it has to be tested at 0.5 and 0.2 atm, respectively. These results have implications for the feasibility and design of DBD plasma actuators for jet engine flow control applications. In addition, the distributions of unit Reynolds number, Mach number, and velocity along the engine are provided. The engine models are non-proprietary and this information can be used for evaluation of other types of actuators and for other purposes.


Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 764 ◽  
Author(s):  
Takayuki Matsunuma ◽  
Takehiko Segawa

Passage vortex exists as one of the typical secondary flows in turbomachines and generates a significant total pressure loss and degrades the aerodynamic performance. Herein, a dielectric barrier discharge (DBD) plasma actuator was utilized for an active flow control of the passage vortex in a linear turbine cascade. The plasma actuator was installed on the endwall, 10 mm upstream from the leading edge of the turbine cascade. The freestream velocity at the outlet of the linear turbine cascade was set to range from UFS,out = 2.4 m/s to 25.2 m/s, which corresponded to the Reynolds number ranging from Reout = 1.0 × 104 to 9.9 × 104. The two-dimensional velocity field at the outlet of the linear turbine cascade was experimentally analyzed by particle image velocimetry (PIV). At lower freestream velocity conditions, the passage vortex was almost negligible as a result of the plasma actuator operation (UPA,max/UFS,out = 1.17). Although the effect of the jet induced by the plasma actuator weakened as the freestream velocity increased, the magnitude of the peak vorticity was reduced under all freestream velocity conditions. Even at the highest freestream velocity condition of UFS,out = 25.2 m/s, the peak value of the vorticity was reduced approximately 17% by the plasma actuator operation at VAC = 15 kVp-p (UPA,max/UFS,out = 0.18).