Improvement of the Flue Gas Cleaning System in Radioactive Waste Incineration Facilities

Author(s):  
Bowen Zheng ◽  
Xiaohai Li ◽  
Haoran Chu ◽  
Chengming Jia ◽  
Wei Xu ◽  
...  

Three radioactive waste incineration facilities have been built in China. The first one has been in operation for more than ten years. Some problems, such as corrosion and waste water treatment in the flue gas cleaning system, have been found in the long time operation of the first facility. According to the origin of the problems, technical process and equipment material of the flue gas cleaning system have been improved in design and been adopted by the second facilities in China. The results showed that most of the problems were resolved, and the improvement is successful.

1996 ◽  
Vol 33 (5) ◽  
pp. 383-388 ◽  
Author(s):  
Jürgen Gottschalk ◽  
Peter Buttmann ◽  
Torgny Johansson

2013 ◽  
Vol 791-793 ◽  
pp. 200-203
Author(s):  
Guang Yao Zhao ◽  
Feng Qing Zhao ◽  
Shaoj Jie Liu ◽  
Hong Jie Liu

The process of BaS reacting with Na2SO4 from waste water to generate BaSO4 is an ideal waste water treatment process, in spite of the shortage to generate lots of by-products, the dilute solution of Na2S. A way of using dilute Na2S solution to absorb SO2 is introduced in this paper. Some problems concerning this process were discussed.


1998 ◽  
Vol 8 (1) ◽  
pp. 69-76 ◽  
Author(s):  
Magnus Pettersson ◽  
Bernt Nilsson ◽  
Jonas Birgersson ◽  
Erik Simonson