New hybrid reflectance optical pulse oximetry sensor for lower oxygen saturation measurement and for broader clinical application

Author(s):  
Masamichi Nogawa ◽  
Chong Thong Ching ◽  
Takeyuki Ida ◽  
Keiko Itakura ◽  
Setsuo Takatani
The Lancet ◽  
1992 ◽  
Vol 339 (8793) ◽  
pp. 615 ◽  
Author(s):  
J. Buschmann ◽  
G. Rall ◽  
R. Knitza

2010 ◽  
Vol 54 (7) ◽  
pp. 1017-1019 ◽  
Author(s):  
Jonathan E. Mullin ◽  
Ben Cooper ◽  
Sinziana Seicean ◽  
Robert Strunk ◽  
Carol Rosen ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shinshu Katayama ◽  
Jun Shima ◽  
Ken Tonai ◽  
Kansuke Koyama ◽  
Shin Nunomiya

AbstractRecently, maintaining a certain oxygen saturation measured by pulse oximetry (SpO2) range in mechanically ventilated patients was recommended; attaching the INTELLiVENT-ASV to ventilators might be beneficial. We evaluated the SpO2 measurement accuracy of a Nihon Kohden and a Masimo monitor compared to actual arterial oxygen saturation (SaO2). SpO2 was simultaneously measured by a Nihon Kohden and Masimo monitor in patients consecutively admitted to a general intensive care unit and mechanically ventilated. Bland–Altman plots were used to compare measured SpO2 with actual SaO2. One hundred mechanically ventilated patients and 1497 arterial blood gas results were reviewed. Mean SaO2 values, Nihon Kohden SpO2 measurements, and Masimo SpO2 measurements were 95.7%, 96.4%, and 96.9%, respectively. The Nihon Kohden SpO2 measurements were less biased than Masimo measurements; their precision was not significantly different. Nihon Kohden and Masimo SpO2 measurements were not significantly different in the “SaO2 < 94%” group (P = 0.083). In the “94% ≤ SaO2 < 98%” and “SaO2 ≥ 98%” groups, there were significant differences between the Nihon Kohden and Masimo SpO2 measurements (P < 0.0001; P = 0.006; respectively). Therefore, when using automatically controlling oxygenation with INTELLiVENT-ASV in mechanically ventilated patients, the Nihon Kohden SpO2 sensor is preferable.Trial registration UMIN000027671. Registered 7 June 2017.


Biofeedback ◽  
2012 ◽  
Vol 40 (4) ◽  
pp. 137-141 ◽  
Author(s):  
Christopher Gilbert

Small pulse oximeters have become widely available and can be useful for noninvasive monitoring of blood oxygen saturation by nonmedical personnel. When training control of breathing, an oximeter helps to reassure clients who hyperventilate that their oxygenation is adequate, offsetting their perception that they are not getting enough air. Low saturation may indicate a medical condition that impairs oxygen absorption. In that case, hyperventilation is a biological compensation that should not be tampered with.


2005 ◽  
Vol 18 (5) ◽  
pp. A110-A111
Author(s):  
A LEONE ◽  
C BELLOTTO ◽  
D GIANNINI ◽  
A BALBARINI

2017 ◽  
Vol 17 (12) ◽  
pp. 3900-3908 ◽  
Author(s):  
Deepak Mishra ◽  
Neha Priyadarshini ◽  
Supriya Chakraborty ◽  
Mukul Sarkar

Sign in / Sign up

Export Citation Format

Share Document