scholarly journals Accuracy of two pulse-oximetry measurements for INTELLiVENT-ASV in mechanically ventilated patients: a prospective observational study

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shinshu Katayama ◽  
Jun Shima ◽  
Ken Tonai ◽  
Kansuke Koyama ◽  
Shin Nunomiya

AbstractRecently, maintaining a certain oxygen saturation measured by pulse oximetry (SpO2) range in mechanically ventilated patients was recommended; attaching the INTELLiVENT-ASV to ventilators might be beneficial. We evaluated the SpO2 measurement accuracy of a Nihon Kohden and a Masimo monitor compared to actual arterial oxygen saturation (SaO2). SpO2 was simultaneously measured by a Nihon Kohden and Masimo monitor in patients consecutively admitted to a general intensive care unit and mechanically ventilated. Bland–Altman plots were used to compare measured SpO2 with actual SaO2. One hundred mechanically ventilated patients and 1497 arterial blood gas results were reviewed. Mean SaO2 values, Nihon Kohden SpO2 measurements, and Masimo SpO2 measurements were 95.7%, 96.4%, and 96.9%, respectively. The Nihon Kohden SpO2 measurements were less biased than Masimo measurements; their precision was not significantly different. Nihon Kohden and Masimo SpO2 measurements were not significantly different in the “SaO2 < 94%” group (P = 0.083). In the “94% ≤ SaO2 < 98%” and “SaO2 ≥ 98%” groups, there were significant differences between the Nihon Kohden and Masimo SpO2 measurements (P < 0.0001; P = 0.006; respectively). Therefore, when using automatically controlling oxygenation with INTELLiVENT-ASV in mechanically ventilated patients, the Nihon Kohden SpO2 sensor is preferable.Trial registration UMIN000027671. Registered 7 June 2017.

2020 ◽  
Vol 58 (230) ◽  
Author(s):  
Nabin Rauniyar ◽  
Shyam Pujari ◽  
Pradeep Shrestha

Introduction: Pulse oximetery is expected to be an indirect estimation of arterial oxygen saturation. However, there often are gaps between SpO2 and SaO2. This study aims to study on arterial oxygen saturation measured by pulse oximetry and arterial blood gas among patients admitted in intensive care unit. Methods: It was a hospital-based descriptive cross-sectional study in which 101 patients meeting inclusion criteria were studied. SpO2 and SaO2 were measured simultaneously. Mean±SD of SpO2 and SaO2 with accuracy, sensitivity and specificity were measured. Results: According to SpO2 values, out of 101 patients, 26 (25.7%) were hypoxemic and 75 (74.25%) were non–hypoxemic. The mean±SD of SaO2 and SpO2 were 93.22±7.84% and 92.85±6.33% respectively. In 21 patients with SpO2<90%, the mean±SD SaO2 and SpO2 were 91.63±4.92 and 87.42±2.29 respectively. In 5 patients with SpO2 < 80%, the mean ± SD of SaO2 and SpO2 were: 63.40±3.43 and 71.80±4.28, respectively. In non–hypoxemic group based on SpO2 values, the mean±SD of SpO2 and SaO2 were 95.773±2.19% and 95.654±3.01%, respectively. The agreement rate of SpO2 and SaO2 was 83.2%, and sensitivity and specificity of PO were 84.6% and 83%, respectively. Conclusions: Pulse Oximetry has high accuracy in estimating oxygen saturation with sp02>90% and can be used instead of arterial blood gas.


1994 ◽  
Vol 3 (5) ◽  
pp. 353-355 ◽  
Author(s):  
ML Noll ◽  
JF Byers

Correlations of mixed venous and arterial oxygen saturation, heart rate, respiratory rate, and mean arterial pressure with arterial blood gas variables were computed for 57 sets of data obtained from 30 postoperative coronary artery bypass graft patients who were being weaned from mechanical ventilation. Arterial oxygen saturation and respiratory rate correlated significantly, although moderately, with blood gases.


2016 ◽  
Vol 29 (5) ◽  
pp. 343
Author(s):  
Miguel Pinto da Costa ◽  
Henrique Pimenta Coelho

<p>The authors present a case of a 60-year-old male patient, previously diagnosed with B-cell chronic lymphocytic leukemia, who was admitted to the Emergency Room with dyspnea. The initial evaluation revealed severe anemia (Hgb = 5.0 g/dL) with hyperleukocytosis (800.000/µL), nearly all of the cells being mature lymphocytes, a normal chest X-ray and a low arterial oxygen saturation (89%; pulse oximetry). After red blood cell transfusion, Hgb values rose (9.0 g/dL) and there was a complete reversion of the dyspnea. Yet, subsequent arterial blood gas analysis, without the administration of supplemental oxygen, systematically revealed very low oxygen saturation values (~ 46%), which was inconsistent with the patient’s clinical state and his pulse oximetry values (~ 87%), and these values were not corrected by the administration of oxygen via non-rebreather mask. The investigation performed allowed to establish the diagnosis of oxygen leukocyte larceny, a phenomenon which conceals the true oxygen saturation due to peripheral consumption by leukocytes.</p>


Author(s):  
Aslıhan Gürün Kaya ◽  
Miraç Öz ◽  
İREM AKDEMİR KALKAN ◽  
Ezgi Gülten ◽  
güle AYDIN ◽  
...  

Introduction: Guidelines recommend using a pulse oximeter rather than arterial blood gas (ABG) for COVID-19 patients. However, significant differences can be observed between oxygen saturation measured by pulse oximetry (SpO2) and arterial oxygen saturation (SaO2) in some clinical conditions. We aimed to assess the reliability of pulse oximeter in patients with COVID-19 Methods: We retrospectively reviewed ABG analyses and SpO2 levels measured simultaneously with ABG in patients hospitalized in COVID-19 wards. Results: We categorized total 117 patients into two groups; in whom the difference between SpO2 and SaO2 was 4% (acceptable difference) and >4% (large difference). Large difference group exhibited higher neutrophil count, C-reactive protein, ferritin, fibrinogen, D-dimer and lower lymphocyte count. Multivariate analyses revealed that increased fibrinogen, increased ferritin and decreased lymphocyte count were independent risk factors for large difference between SpO2 and SaO2. The total study group demonstrated the negative bias of 4.02% with the limits of agreement of −9.22% to 1.17%. The bias became significantly higher in patients with higher ferritin, fibrinogen levels and lower lymphocyte count. Conclusion: Pulse oximeters may not be sufficient to assess actual oxygen saturation especially in COVID-19 patients with high ferritin and fibrinogen levels and low lymphocyte count low SpO2 measurements.


2021 ◽  
Author(s):  
Shan Wang ◽  
Liga Yusvirazi ◽  
Haiyan Yin ◽  
Hongjun Kang ◽  
Yan Zhao ◽  
...  

Abstract Objectives: Arterial blood gas measurements are not always immediately available despite their potential relevance to management of mechanically ventilated patients. Retrospective and prospective studies have validated the non-linear imputation of PaO2/FIO2 from SpO2/FIO2, predominantly in USA. In this study, the objective was to validate the non-linear imputation algorithm among mechanically ventilated patients in the Chinese population. Method: Mechanically ventilated patients admitted to the emergency departments or ICUs at two participating hospitals in China were enrolled prospectively. At the time of a clinical arterial blood gas being drawn, SpO2, oximeter waveform characteristics, receipt of vasopressor, and skin pigmentation were simultaneously recorded. For the various imputation methods, we calculated both imputation error and the area under the curve for patients meeting criteria for acute respiratory distress syndrome (PaO2/FIO2 ≤ 300) and moderate-severe acute respiratory distress syndrome (PaO2/FIO2 ≤ 150). Result: We studied 663 arterial blood gases from 646 patients; 177 (26%) arterial blood gases were associated with SpO2 less than or equal to 96%. Non-linear imputation had lower mean absolute error than linear imputation method when SpO2 was less than or equal to 96% (p<0.001). At the PaO2/FiO2 threshold of 300 or less, non-linear imputation AUC (0.90 95% CI 0.85-0/95) was not significantly higher than the AUCs of linear and log-linear imputation methods (0.88 95% CI 0.82-0.94). The same result was shown at the PaO2 /FiO2 threshold of 150 or less. For patients with a threshold SpO2 of 96% or less, AUC analysis yielded similar results between non-linear vs. linear and log-linear imputations. Conclusions: In this cohort of mechanically ventilated patients, non-linear imputation was not superior to linear and log-linear imputations for patients with SpO2 of 96% or less. All strategies performed similarly in estimating PaO2/FIO2 from SpO2/FIO2.


2005 ◽  
Vol 51 (2) ◽  
pp. 434-444 ◽  
Author(s):  
Shannon Haymond ◽  
Rohit Cariappa ◽  
Charles S Eby ◽  
Mitchell G Scott

Abstract Background: This case conference reviews laboratory methods for assessing oxygenation status: arterial blood gases, pulse oximetry, and CO-oximetry. Caveats of these measurements are discussed in the context of two methemoglobinemia cases. Cases: Case 1 is a woman who presented with increased shortness of breath, productive cough, chest pain, nausea, fever, and cyanosis. CO-oximetry indicated a carboxyhemoglobin (COHb) fraction of 24.9%. She was unresponsive to O2 therapy, and no source of carbon monoxide could be noted. Case 2 is a man who presented with syncope, chest tightness, and signs of cyanosis. His arterial blood was dark brown, and CO-oximetry showed a methemoglobin (MetHb) fraction of 23%. Issues: Oxygen saturation (So2) can be measured by three approaches that are often used interchangeably, although the measured systems are quite different. Pulse oximetry is a noninvasive, spectrophotometric method to determine arterial oxygen saturation (SaO2). CO-oximetry is a more complex and reliable method that measures the concentration of hemoglobin derivatives in the blood from which various quantities such as hemoglobin derivative fractions, total hemoglobin, and saturation are calculated. Blood gas instruments calculate the estimated O2 saturation from empirical equations using pH and Po2 values. In most patients, the results from these methods will be virtually identical, but in cases of increased dyshemoglobin fractions, including methemoglobinemia, it is crucial that the distinctions and limitations of these methods be understood. Conclusions: So2 calculated from pH and Po2 should be interpreted with caution as the algorithms used assume normal O2 affinity, normal 2,3-diphosphoglycerate concentrations, and no dyshemoglobins or hemoglobinopathies. CO-oximeter reports should include the dyshemoglobin fractions in addition to the oxyhemoglobin fraction. In cases of increased MetHb fraction, pulse oximeter values trend toward 85%, underestimating the actual oxygen saturation. Hemoglobin M variants may yield normal MetHb and increased COHb or sulfhemoglobin fractions measured by CO-oximetry.


PEDIATRICS ◽  
1989 ◽  
Vol 84 (2) ◽  
pp. 226-230
Author(s):  
Hans-Ulrich Bucher ◽  
Sergio Fanconi ◽  
Peter Baeckert ◽  
Gabriel Duc

Pulse oximetry has been proposed as a non-invasive continuous method for transcutaneous monitoring of arterial oxygen saturation of hemoglobin (tcSO2) in the newborn infant. The reliability of this technique in detecting hyperoxemia is controversial, because small changes in saturation greater than 90% are associated with relatively large changes in arterial oxygen tension (PaO2). The purpose of this study was to assess the reliability of pulse oximetry using an alarm limit of 95% tcSO2 in detecting hyperoxemia (defined as PaO2 greater than 90 mm Hg) and to examine the effect of varying the alarm limit on reliability. Two types of pulse oximeter were studied alternately in 50 newborn infants who were mechanically ventilated with indwelling arterial lines. Three arterial blood samples were drawn from every infant during routine increase of inspired oxygen before intratracheal suction, and PaO2 was compared with tcSO2. The Nellcor N-100 pulse oximeter identified all 26 hyperoxemic instances correctly (sensitivity 100%) and alarmed falsely in 25 of 49 nonhyperoxemic instances (specificity 49%). The Ohmeda Biox 3700 pulse oximeter detected 13 of 35 hyperoxemic instances (sensitivity 37%) and alarmed falsely in 7 of 40 nonhyperoxemic instances (specificity 83%). The optimal alarm limit, defined as a sensitivity of 95% or more associated with maximal specificity, was determined for Nellcor N-100 at 96% tcSO2 (specificity 38%) and for Ohmeda Biox 3700 at 89% tcSO2 (specificity 52%). It was concluded that pulse oximeters can be highly sensitive in detecting hyperoxemia provided that type-specific alarm limits are set and a low specificity is accepted.


1944 ◽  
Vol 79 (1) ◽  
pp. 9-22 ◽  
Author(s):  
Frank L. Engel ◽  
Helen C. Harrison ◽  
C. N. H. Long

1. In a series of rats subjected to hemorrhage and shock a high negative correlation was found between the portal and peripheral venous oxygen saturations and the arterial blood pressure on the one hand, and the blood amino nitrogen levels on the other, and a high positive correlation between the portal and the peripheral oxygen saturations and between each of these and the blood pressure. 2. In five cats subjected to hemorrhage and shock the rise in plasma amino nitrogen and the fall in peripheral and portal venous oxygen saturations were confirmed. Further it was shown that the hepatic vein oxygen saturation falls early in shock while the arterial oxygen saturation showed no alteration except terminally, when it may fall also. 3. Ligation of the hepatic artery in rats did not affect the liver's ability to deaminate amino acids. Hemorrhage in a series of hepatic artery ligated rats did not produce any greater rise in the blood amino nitrogen than a similar hemorrhage in normal rats. The hepatic artery probably cannot compensate to any degree for the decrease in portal blood flow in shock. 4. An operation was devised whereby the viscera and portal circulation of the rat were eliminated and the liver maintained only on its arterial circulation. The ability of such a liver to metabolize amino acids was found to be less than either the normal or the hepatic artery ligated liver and to have very little reserve. 5. On complete occlusion of the circulation to the rat liver this organ was found to resist anoxia up to 45 minutes. With further anoxia irreversible damage to this organ's ability to handle amino acids occurred. 6. It is concluded that the blood amino nitrogen rise during shock results from an increased breakdown of protein in the peripheral tissues, the products of which accumulate either because they do not circulate through the liver at a sufficiently rapid rate or because with continued anoxia intrinsic damage may occur to the hepatic parenchyma so that it cannot dispose of amino acids.


Sign in / Sign up

Export Citation Format

Share Document