Time-resolved fluorescence measurements for diffuse optical tomography using ultrafast time-correlated single photon counting

Author(s):  
Yves Bérubé-Lauzière ◽  
Vincent Robichaud

Four methods of applying mode-locked lasers to time-resolved fluorescence measurements in the subnanosecond region are compared. When time resolution below 100 ps is not required, the most precise and sensitive method is single-photon counting, and the application of this method to studies of time-resolved fluorescence of tryptophan in simple peptides is described. The dependence of lifetimes on pH and temperature are interpreted in terms of quenching by intramolecular proton and electron transfers.


2005 ◽  
Author(s):  
Wolfgang Becker ◽  
Axel Bergmann ◽  
Adam Gibson ◽  
Nick Everdell ◽  
David Jennions ◽  
...  

2016 ◽  
Vol 2016 ◽  
pp. 1-23 ◽  
Author(s):  
Yves Bérubé-Lauzière ◽  
Matteo Crotti ◽  
Simon Boucher ◽  
Seyedrohollah Ettehadi ◽  
Julien Pichette ◽  
...  

This paper discusses instrumentation based on multiview parallel high temporal resolution (<50 ps) time-domain (TD) measurements for diffuse optical tomography (DOT) and a prospective view on the steps to undertake as regards such instrumentation to make TD-DOT a viable technology for small animal molecular imaging. TD measurements provide information-richest data, and we briefly review the interaction of light with biological tissues to provide an understanding of this. This data richness is yet to be exploited to its full potential to increase the spatial resolution of DOT imaging and to allow probing, via the fluorescence lifetime, tissue biochemical parameters, and processes that are otherwise not accessible in fluorescence DOT. TD data acquisition time is, however, the main factor that currently compromises the viability of TD-DOT. Current high temporal resolution TD-DOT scanners simply do not integrate sufficient detection channels. Based on our past experience in developing TD-DOT instrumentation, we review and discuss promising technologies to overcome this difficulty. These are single photon avalanche diode (SPAD) detectors and fully parallel highly integrated electronics for time-correlated single photon counting (TCSPC). We present experimental results obtained with such technologies demonstrating the feasibility of next-generation multiview TD-DOT therewith.


2017 ◽  
Vol 66 (10) ◽  
pp. 2505-2515 ◽  
Author(s):  
Jonathan Bouchard ◽  
Arnaud Samson ◽  
William Lemaire ◽  
Caroline Paulin ◽  
Jean-Francois Pratte ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document