acquisition time
Recently Published Documents


TOTAL DOCUMENTS

1137
(FIVE YEARS 499)

H-INDEX

36
(FIVE YEARS 10)

Cancers ◽  
2022 ◽  
Vol 14 (2) ◽  
pp. 384
Author(s):  
Teresa Resende Neves ◽  
Mariana Tomé Correia ◽  
Maria Ana Serrado ◽  
Mariana Horta ◽  
António Proença Caetano ◽  
...  

Endometrial cancer is the eighth most common cancer worldwide, and its prognosis depends on various factors, with myometrial invasion having a major impact on prognosis. Optimizing MRI protocols is essential, and it would be useful to improve the diagnostic accuracy without the need for other sequences. We conducted a retrospective, single-center study, which included a total of 87 patients with surgically confirmed primary endometrial cancer, and who had undergone a pre-operative pelvic MRI. All exams were read by an experienced radiologist dedicated to urogenital radiology, and the depth of myometrial invasion was evaluated using T2-Weighted Images (T2WI) and fused T2WI with Diffusion-Weighted Images (DWI). Both results were compared to histopathological evaluations. When comparing both sets of imaging (T2WI and fused T2WI-DWI images) in diagnosing myometrial invasion, the fused images had better accuracy, and this difference was statistically significant (p < 0.001). T2WI analysis correctly diagnosed 82.1% (70.6–88.7) of cases, compared to 92.1% correctly diagnosed cases with fused images (79.5–97.2). The addition of fused images to a standard MRI protocol improves the diagnostic accuracy of myometrial invasion depth, encouraging its use, since it does not require more acquisition time.


2022 ◽  
Vol 12 (2) ◽  
pp. 738
Author(s):  
Revital Marbel ◽  
Roi Yozevitch ◽  
Tal Grinshpoun ◽  
Boaz Ben-Moshe

Satellite network optimization is essential, particularly since the cost of manufacturing, launching and maintaining each satellite is significant. Moreover, classical communication optimization methods, such as Minimal Spanning Tree, cannot be applied directly in dynamic scenarios where the satellite constellation is constantly changing. Motivated by the rapid growth of the Star-Link constellation that, as of Q4 2021, consists of over 1600 operational LEO satellites with thousands more expected in the coming years, this paper focuses on the problem of constructing an optimal inter-satellite (laser) communication network. More formally, given a large set of LEO satellites, each equipped with a fixed number of laser links, we direct each laser module on each satellite such that the underlying laser network will be optimal with respect to a given objective function and communication demand. In this work, we present a novel heuristic to create an optimal dynamic optical network communication using an Ant Colony algorithm. This method takes into account both the time it takes to establish an optical link (acquisition time) and the bounded number of communication links, as each satellite has a fixed amount of optical communication modules installed. Based on a large number of simulations, we conclude that, although the underlying problem of bounded-degree-spanning-tree is NP-hard (even for static cases), the suggested ant-colony heuristic is able to compute cost-efficient solutions in semi-real-time.


2022 ◽  
Author(s):  
Giorgio D‘Ettorre ◽  
Marco Farronato ◽  
Ettore Candida ◽  
Vincenzo Quinzi ◽  
Cristina Grippaudo

ABSTRACT Objectives To compare three-dimensional facial scans obtained by stereophotogrammetry with two different applications for smartphone supporting the TrueDepth system, a structured light technology. Materials and Methods Facial scans of 40 different subjects were acquired with three different systems. The 3dMDtrio Stereophotogrammetry System (3dMD, Atlanta, Ga) was compared with a smartphone (iPhone Xs; Apple, Cupertino, Calif) equipped with the Bellus3D Face Application (version 1.6.11; Bellus3D Inc, Campbell, Calif) or Capture (version 1.2.5; Standard Cyborg Inc, San Francisco, Calif). Times of image acquisition and elaboration were recorded. The surface-to-surface deviation and the distance between 18 landmarks from 3dMD reference images to those acquired with Bellus3D or Capture were measured. Results Capturing and processing times with the smartphone applications were considerably longer than with the 3dMD system. The surface-to-surface deviation analysis between the Bellus3D and 3dMD showed an overlap percentage of 80.01% ± 5.92% and 56.62% ± 7.65% within the ranges of 1 mm and 0.5 mm discrepancy, respectively. Images from Capture showed an overlap percentage of 81.40% ± 9.59% and 56.45% ± 11.62% within the ranges of 1 mm and 0.5 mm, respectively. Conclusions The face image acquisition with the 3dMD device is fast and accurate, but bulky and expensive. The new smartphone applications combined with the TrueDepth sensors show promising results. They need more accuracy from the operator and more compliance from the patient because of the increased acquisition time. Their greatest advantages are related to cost and portability.


Herz ◽  
2022 ◽  
Author(s):  
Uzair Ansari ◽  
Sonja Janssen ◽  
Stefan Baumann ◽  
Martin Borggrefe ◽  
Stephan Waldeck ◽  
...  

Abstract Background We investigated the feasibility of evaluating coronary arteries with a contrast-enhanced (CE) self-navigated sparse isotropic 3D whole heart T1-weighted magnetic resonance imaging (MRI) study sequence. Methods A total of 22 consecutive patients underwent coronary angiography and/or cardiac computed tomography (CT) including cardiac MRI. The image quality was evaluated on a 3-point Likert scale. Inter-reader variability for image quality was analyzed with Cohen’s kappa for the main coronary segments (left circumflex [LCX], left anterior descending [LAD], right coronary artery [RCA]) and the left main trunk (LMT). Results Inter-reader agreement for image quality of the coronary tree ranged from substantial to perfect, with a Cohen’s kappa of 0.722 (RCAmid) to 1 (LCXprox). The LMT had the best image quality. Image quality of the proximal vessel segments differed significantly from the mid- and distal segments (RCAprox vs. RCAdist, p < 0.05). The LCX segments showed no significant difference in image quality along the vessel length (LCXprox vs. LCXdist, p = n.s.). The mean acquisition time for the study sequence was 553 s (±46 s). Conclusion Coronary imaging with a sparse 3D whole-heart sequence is feasible in a reasonable amount of time producing good-quality imaging. Image quality was poorer in distal coronary segments and along the entire course of the LCX.


2022 ◽  
Vol 24 (1) ◽  
Author(s):  
Anastasia Fotaki ◽  
Camila Munoz ◽  
Yaso Emanuel ◽  
Alina Hua ◽  
Filippo Bosio ◽  
...  

Abstract Background The application of cardiovascular magnetic resonance angiography (CMRA) for the assessment of thoracic aortic disease is often associated with prolonged and unpredictable acquisition times and residual motion artefacts. To overcome these limitations, we have integrated undersampled acquisition with image-based navigators and inline non-rigid motion correction to enable a free-breathing, contrast-free Cartesian CMRA framework for the visualization of the thoracic aorta in a short and predictable scan of 3 min. Methods 35 patients with thoracic aortic disease (36 ± 13y, 14 female) were prospectively enrolled in this single-center study. The proposed 3D T2-prepared balanced steady state free precession (bSSFP) sequence with image-based navigator (iNAV) was compared to the clinical 3D T2-prepared bSSFP with diaphragmatic-navigator gating (dNAV), in terms of image acquisition time. Three cardiologists blinded to iNAV vs. dNAV acquisition, recorded image quality scores across four aortic segments and their overall diagnostic confidence. Contrast ratio (CR) and relative standard deviation (RSD) of signal intensity (SI) in the corresponding segments were estimated. Co-axial aortic dimensions in six landmarks were measured by two readers to evaluate the agreement between the two methods, along with inter-observer and intra-observer agreement. Kolmogorov–Smirnov test, Mann–Whitney U (MWU), Bland–Altman analysis (BAA), intraclass correlation coefficient (ICC) were used for statistical analysis. Results The scan time for the iNAV-based approach was significantly shorter (3.1 ± 0.5 min vs. 12.0 ± 3.0 min for dNAV, P = 0.005). Reconstruction was performed inline in 3.0 ± 0.3 min. Diagnostic confidence was similar for the proposed iNAV versus dNAV for all three reviewers (Reviewer 1: 3.9 ± 0.3 vs. 3.8 ± 0.4, P = 0.7; Reviewer 2: 4.0 ± 0.2 vs. 3.9 ± 0.3, P = 0.4; Reviewer 3: 3.8 ± 0.4 vs. 3.7 ± 0.6, P = 0.3). The proposed method yielded higher image quality scores in terms of artefacts from respiratory motion, and non-diagnostic images due to signal inhomogeneity were observed less frequently. While the dNAV approach outperformed the iNAV method in the CR assessment, the iNAV sequence showed improved signal homogeneity along the entire thoracic aorta [RSD SI 5.1 (4.4, 6.5) vs. 6.5 (4.6, 8.6), P = 0.002]. BAA showed a mean difference of < 0.05 cm across the 6 landmarks between the two datasets. ICC showed excellent inter- and intra-observer reproducibility. Conclusions Thoracic aortic iNAV-based CMRA with fast acquisition (~ 3 min) and inline reconstruction (3 min) is proposed, resulting in high diagnostic confidence and reproducible aortic measurements.


Author(s):  
I Made Yuliara ◽  
Ni Nyoman Ratini ◽  
I Gde Antha Kasmawan

This study aims to analyze temporally the spectral reflectance of clove vegetation using Landsat 8 multitemporal imagery data in Buleleng district, Bali. The analysis method uses the conversion of raw data from Landsat 8 images to the spectral reflectance value at the Top of Atmosphere (TOA). This conversion scales back the pixel values ??of the Landsat 8 image in the visible spectrum, namely bands 2, 3, 4 and infrared bands 5, 6, and 7 into percentage units. The temporal analysis technique is carried out by grouping the time series of Landsat 8 image data for 1 period, in 2015, into 4 quarterly groups based on the acquisition time, namely Quarter I (January, February, March), Quarter II (April, May, June), Quarter III (July, August, September) and Quarter IV (October, November, December). The results showed that the graph pattern of the average percentage of spectral reflectance in each quarter was the same and in the infrared spectrum was greater than the visible spectrum. The average value of the largest spectral reflectance was found in the second Quarter which was acquired by band 5 of 28.143%, while the smallest in the first Quarter which was acquired by band 2 was 2.503%.


Micromachines ◽  
2022 ◽  
Vol 13 (1) ◽  
pp. 94
Author(s):  
Xiaozhen Ren ◽  
Yanwen Bai ◽  
Yingying Niu ◽  
Yuying Jiang

In order to solve the problems of long-term image acquisition time and massive data processing in a terahertz time domain spectroscopy imaging system, a novel fast terahertz imaging model, combined with group sparsity and nonlocal self-similarity (GSNS), is proposed in this paper. In GSNS, the structure similarity and sparsity of image patches in both two-dimensional and three-dimensional space are utilized to obtain high-quality terahertz images. It has the advantages of detail clarity and edge preservation. Furthermore, to overcome the high computational costs of matrix inversion in traditional split Bregman iteration, an acceleration scheme based on conjugate gradient method is proposed to solve the terahertz imaging model more efficiently. Experiments results demonstrate that the proposed approach can lead to better terahertz image reconstruction performance at low sampling rates.


Author(s):  
Andrea Securo ◽  
Emanuele Forte ◽  
Davide Martinucci ◽  
Simone Pillon ◽  
Renato R Colucci

This study investigates the application of a terrestrial structure from motionmulti-view stereo (SfM-MVS) approach combined with ground-penetrating radar (GPR) surveys for monitoring the surface topographic change of two permanent ice deposits in caves located in the Julian Alps (south-eastern European Alps). This method allows accurate calculation of both seasonal and annual mass balance, estimating the amount of ice inside caves. The ground-based SfM approach represents a low-cost workflow with very limited logistical problems of transportation and human resources and a fast acquisition time, all key factors in such extreme environments. Under optimal conditions, SfM-MVS allows sub-centimetric resolution results, comparable to more expensive and logistically demanding surveys such as terrestrial laser scanning (TLS). Fourteen SfM acquisitions were made between the 2017–2020 ablation seasons (i.e. July–October) while 2 GPR surveys were acquired in 2012. The obtained dense point clouds and digital terrain models (DTMs) made possible a reliable calculation of topographic changes and mass balance rates during the analysed period. The integration of SfM-MVS products with GPR surveys provided comprehensive imaging of the ice thickness and the total ice volume present in each of the caves, proving to be a reliable, low cost and multipurpose methodology ideal for long-term monitoring.


2022 ◽  
Vol 12 (2) ◽  
pp. 584
Author(s):  
Sherif M. Hanafy

Near-surface high-resolution seismic mapping is very important in many applications such as engineering and environmental. However, the conventional setup of the seismic technique requires planting geophones, connecting cables, and then collecting all equipment after completing the survey, which is time-consuming. In this study, we suggest using a land-streamer setup rather than the conventional setup for fast, accurate, and high-resolution near-surface seismic surveys. Only one field data set is recorded using both the conventional and the land-streamer setups. The recorded data is then compared in terms of time, frequency, wavenumber domains, and acquisition time. Following this, we compared the accuracy of the subsurface mapping of both setups using a synthetic example. The results show that the conventional setup can reach deeper depths but with lower accuracy, where the errors in imaging the local anomalies’ widths and thicknesses are 77% to 145% and 35% to 50%, respectively. The land-streamer setup provides accurate near-surface results but shallower penetration depth, here the errors in the anomalies’ widths and thicknesses are 5% to 12% and 10% to 20%, respectively.


Author(s):  
Elżbieta Górska-Horczyczak ◽  
Magdalena Zalewska ◽  
Agnieszka Wierzbicka

AbstractThe aim of the study was to compare the effectiveness of the use of low-peak chromatographic fingerprints for the differentiation of various food products. Three groups of unprocessed products (mushrooms, hazelnuts and tomatoes), food preparations (bread, dried herbs and tomato juice) and alcoholic beverages (vodka and two types of blended whiskey) were examined. A commercial electronic nose based on ultrafast gas chromatography (acquisition time 90 s) with a flame ionization detector was used for the research. Static headspace was used as a green procedure to extract volatile compounds without modifying the food matrix. Individual extraction conditions were used for each product group. Similarities and differences between profiles were analyzed by simple Principal Components Analysis. The similarity rating was determined using the Euclidean distances. Global model was built for recognition chromatographic fingerprints of food samples. The best recognition results were 100% and 89% for tomato juices, spices, separate champignon elements and hazelnuts. On the other hand, the worst recognition results were 56% and 77% for breads and strong alcoholic beverages.


Sign in / Sign up

Export Citation Format

Share Document