Air and Bone Conduction Pure Tone Detection Thresholds for Squirrel Monkey

1971 ◽  
Vol 50 (1A) ◽  
pp. 147-148
Author(s):  
C. R. Wilpizeski ◽  
I. M. Young
1991 ◽  
Vol 69 (8) ◽  
pp. 2059-2066 ◽  
Author(s):  
J. M. Terhune

In-air pure tone detection thresholds of a harbour seal (Phoca vitulina) were measured using behavioural psychophysical techniques. Thresholds dropped from about 70 dB re 20 μPa at 0.1 kHz to about 35 dB re 20 μ Pa at 4 kHz and then increased to about 45 dB re 20 μPa at 16 kHz. Increased sensitivities at 2 and 8 kHz, which have been reported in other pinnipeds, were not evident. In-air intensity detection thresholds averaged 32 dB above their underwater counterparts (1–16 kHz). Masking studies found the critical ratios at 0.25, 0.5, and 1 kHz to be 24, 15, and 21 dB, respectively (white noise masker). From 0.2 to 1.5 kHz, bandwidths 20 dB below the level of pure tone maskers were 0.16–0.18 kHz. Circumstantial evidence suggests the possibility that blood vascular changes associated with diving might also influence the sensitivity of the auditory systems of seals. Under optimal conditions, a pup's airborne cries may be detected by its mother at ranges of 1 km or more.


2020 ◽  
Vol 59 (10) ◽  
pp. 801-808 ◽  
Author(s):  
Karina C. De Sousa ◽  
Cas Smits ◽  
David R. Moore ◽  
Hermanus Carel Myburgh ◽  
De Wet Swanepoel

1978 ◽  
Vol 63 (S1) ◽  
pp. S64-S64
Author(s):  
L. L. Elliott ◽  
D. R. Katz

2020 ◽  
Vol 74 (6) ◽  
pp. 1-5
Author(s):  
Katarzyna Job ◽  
Jacek Składzień

Background The influence of the mechanics of the middle ear on the function of the inner ear has been studied for many years. Among surgeries performed in the middle-ear area, those restoring full functionality of the system transmitting sound inside the middle ear may be pointed out as those fully restoring the mechanical influence of the middle ear on the function of the inner ear. Aim: The aim of the performed analysis is to find the prognostic importance of measured pre-surgery values of bone conduction on the improvement of hearing in patients operated as a result of middle-ear disorders. Methods The analysis included 271 patients hospitalised and operated on due to otosclerosis or perforation of the tympanic membrane between 2016 and 2019. Only patients who had not had a surgical operation within the middle ear prior to the study were included. An audiological assessment was performed with the use of pure tone thresholds audiometry. Results A beneficial influence of the performed surgery on the improvement of bone conduction was observed in patients, in which the average threshold value of bone conduction measured before the surgery did not exceed 40 dB. In cases of the perceptive component of hearing impairment being higher than 40 dB, no statistically significant, beneficial influence of a performed stapedotomy or myringoplasty on the change of bone conduction thresholds was observed. Conclusion The perception component of hearing impairment up to 40 dB indicates bone conduction improvement after surgical restoration of the influence of middle-ear mechanics on the inner ear in patients treated as a result of otosclerosis, as well as of eardrum perforation.


2013 ◽  
Vol 128 (1) ◽  
pp. 35-42
Author(s):  
M L McNeil ◽  
M Gulliver ◽  
D P Morris ◽  
F M Makki ◽  
M Bance

AbstractIntroduction:Patients receiving a bone-anchored hearing aid have well-documented improvements in their quality of life and audiometric performance. However, the relationship between audiometric measurements and subjective improvement is not well understood.Methods:Adult patients enrolled in the Nova Scotia bone-anchored hearing aid programme were identified. The pure tone average for fitting the sound-field threshold, as well as the better and worse hearing ear bone conduction and air conduction levels, were collected pre-operatively. Recipients were asked to complete the Speech, Spatial and Qualities of Hearing questionnaire; their partners were asked to complete a pre- and post-bone anchored hearing aid fitting Hearing Handicap Inventory for Adults questionnaire.Results:Forty-eight patients who completed and returned the Speech, Spatial and Qualities of Hearing questionnaire had partners who completed the Hearing Handicap Inventory for Adults questionnaire. The results from the Speech, Spatial and Qualities of Hearing questionnaire correlated with the sound-field hearing threshold post-bone-anchored hearing aid fitting and the pure tone average of the better hearing ear bone conduction (total Speech, Spatial and Qualities of Hearing Scale to the pre-operative better hearing ear air curve (r = 0.3); worse hearing ear air curve (r = 0.27); post-operative, bone-anchored hearing aid-aided sound-field thresholds (r = 0.35)). An improvement in sound-field threshold correlated only with spatial abilities. In the Hearing Handicap Inventory for Adults questionnaire, there was no correlation between the subjective evaluation of each patient and their partner.Conclusion:The subjective impressions of hearing aid recipients with regards to speech reception and the spatial qualities of hearing correlate well with pre-operative audiometric results. However, the overall magnitude of sound-field improvement predicts an improvement of spatial perception, but not other aspects of hearing, resulting in hearing aid recipients having strongly disparate subjective impressions when compared to those of their partners.


2003 ◽  
Vol 14 (10) ◽  
pp. 556-562 ◽  
Author(s):  
Susan A. Small ◽  
David R. Stapells

Behavioral thresholds were measured from 31 adults with normal hearing for 500, 1000, 2000, and 4000 Hz brief tones presented using a B-71 bone oscillator. Three occlusion conditions were assessed: ears unoccluded, one ear occluded, and both ears occluded. Mean threshold force levels were 67, 54, 49, and 41 dB re:1μN peak-to-peak equivalent in the unoccluded condition for 500, 1000, 2000, and 4000 Hz, respectively (corrected for air-conduction pure-tone thresholds). A significant occlusion effect was observed for 500 and 1000 Hz stimuli. These thresholds may be used as the 0 dB nHL (normalhearing level) for brief-tone bone-conduction stimuli for auditory brainstem response testing.


Author(s):  
Nupur Midha ◽  
Gurbax Singh ◽  
Rachna Dhingra ◽  
Rajwant Kaur

<p class="abstract"><strong>Background:</strong> Tympanic membrane perforations result mainly from infectious and traumatic etiologies. Postoperative outcomes of reconstructive surgeries of hearing mechanism have routinely been assessed by take up rates and air bone gap closure on pure tone testing. The present study was conducted to assess hearing improvement after fat graft myringoplasty.</p><p class="abstract"><strong>Methods:</strong> The present prospective study was conducted from 1<sup>st</sup> January 2017 to 30<sup>th</sup> June 2018. The study population consists of patients of age 18 to 60 years. The subjects with safe or tubotympanic type of chronic suppurative otitis media with small dry central perforation or perforation of the pars tensa less than 3 mm were included in the study. Pure tone audiometry (PTA) was consigned to an audiologist who was blind to the study. Air conduction threshold level was measured at frequencies 0.25 to 8 kHz and bone conduction threshold level was measured at frequencies 0.5 to 4 kHz; average air bone gap of each patient was calculated preoperatively and postoperatively at one and three months at the frequencies 500 Hz, 1000 Hz and 2000 Hz.  </p><p class="abstract"><strong>Results:</strong> Among 30 patients, 15 (50.00%) had pre-operative bone conduction threshold in the range of 0-10 dB HL and rest 15 (50.00%) had between 11-20 dB HL. Majority of them i.e. 20 had post-operative air bone gap in the range of 0-10 dB HL whereas 02 had pre op air bone gap in this range, followed by 07 with air bone gap in the range of 11-20 dB HL as compared to 18 in the pre op and 03 in the range of 21-30 dB HL as compared to 10 in the pre op. Paired t test reveals results are significant.</p><p class="abstract"><strong>Conclusions:</strong> Postoperative audiometry at the end of 1 month revealed majority i.e. 14 had air bone gap in range of 0-10 dB HL thus showing improvement in hearing. Postoperative audiometry at the end of 3 months revealed maximum number of patients i.e. 20 in the range of 0-10 dB HL which showed further improvement in hearing in the form of decrease in air bone gap.</p><p class="Default"> </p>


Sign in / Sign up

Export Citation Format

Share Document