scholarly journals A New Validated RP- HPLC Method for the Determination of Nevirapine in Human Plasma

2010 ◽  
Vol 7 (3) ◽  
pp. 821-826 ◽  
Author(s):  
C. H. Venkata Kumar ◽  
D. Ananth Kumar ◽  
J. V. L. N. Seshagiri Rao

A rapid, selective and sensitive high performance liquid chromatographic method for the estimation of nevirapine in human plasma has been developed. Chromatography was carried out on a Hypersil BDS C18column using a mixture of ammonium acetate buffer (pH 4.0 ± 0.05) and acetonitrile (85:15 v/v) as the mobile phase. The eluents were monitored for the drug by UV detection at 254 nm. Oxcarbazepine was used as an internal standard for this study. The retention times for nevirapine and oxcarbazepine were found to be 7.2 and 14.7 min respectively. The method was found to be linear in the concentration range of 50 ng/mL to 5003.7 ng/mL. The method was validated as per FDA guidelines and was found to be suitable for bioequivalence and pharmacokinetic studies.

2011 ◽  
Vol 94 (3) ◽  
pp. 847-856 ◽  
Author(s):  
Kostas M Zorpas ◽  
Georgia N Valsami ◽  
Evangelos V Vryonis ◽  
Athanasios T Skoutelis ◽  
Helen A Archontaki

Abstract An isocratic HPLC method with detection at 248 nm was developed and fully validated for the determination of tigecycline in rabbit plasma. Minocycline was used as an internal standard. A Hypersil BDS RP-C18 column (250 × 4.6 mm, 5 μm particle size) was used with the mobile phase phosphate buffer (pH 7.10, 0.070 M)–acetonitrile (76 + 24, v/v) at a flow rate of 1.0 mL/min. The elution time of tigecycline and minocycline was approximately 8.1 and 9.9 min, respectively. Calibration curves of tigecycline were linear in the concentration range of 0.021–3.15 μg/mL in plasma. The LOD and LOQ in plasma were estimated as 7 and 21 ng/mL, respectively. The intraday and interday precision values of the method were in the range of 5.0–7.1 and 5.6–9.1%, while the corresponding accuracy values were in the ranges of 92.8–111.1 and 97.6–102.3%, respectively. At the LOQ, the intraday precision was 18.7%, while intraday and interday accuracy values were 97.3 and 98.0%, respectively. Robustness of the proposed method was studied using a Plackett-Burman experimental design. A pharmacokinetic profile is presented for confirmation of the applicability of the method to pharmacokinetic studies.


2003 ◽  
Vol 68 (11) ◽  
pp. 883-892 ◽  
Author(s):  
Dragica Zendelovska ◽  
Trajce Stafilov

A rapid, specific and sensitive high-performance liquid chromatographic method for the determination of famotidine in human plasma has been developed. Famotidine and the internal standard were chromatographically separated from plasma components using a Lichrocart Lichrospher 60 RP select B cartridge for solid-phase separation with a mobile phase composed of 0.1 % (v/v) triethylamine in water (pH 3) and acetonitrile (92:8, v/v). UV detection was set at 270 nm. The calibration curve was linear in the concentration range of 10.0 ? 350.0 ng mL-1. The method was implemented to monitor the famotidine levels in patient samples.


Sign in / Sign up

Export Citation Format

Share Document