liquid chromatographic method
Recently Published Documents


TOTAL DOCUMENTS

2878
(FIVE YEARS 154)

H-INDEX

68
(FIVE YEARS 3)

Author(s):  
Satyabrata Sahu ◽  
U. Sunila Kumar Patra ◽  
Pratap Kumar Patra

Aim: In this present study an accurate reverse phase ultra-performance liquid chromatography (RP-UPLC) method has been developed, validated and applied to stability indicating studies to determine Lercanidipine HCL in bulk and marketed dosage form. Methods: Optimized chromatographic conditions were achieved by using Waters Acquity BEH C18 (2.1 x 50mm, 1.7m) UPLC column. Empower 2 is a software, dihydrogen Orthophosphate Buffer : Methanol (40 : 60)  as eluent at flow rate 0.3 ml/min. PDA detection was performed at 254nm. Results: The developed method was validated and stability study was conducted as per ICH guidelines. The retention time was found at 0.503 min. The method shows linearity over a range of 1 μg/ml to 60 μg /ml with the obtained correlation coefficient is 0.999. The LOD and LOQ values were found 0.025 and 0.05 μg /ml. The acidic and peroxide stressed study shows more degradation of 6.23% and 3.03%. Conclusion: The present developed method was found stability indicating, reliable, validated method was applied for the routine analysis of lercanidipine in bulk drug and the pharmaceutical formulations.


INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (09) ◽  
pp. 65-69
Author(s):  
Atul Sherje ◽  
◽  
Subhash Dhende ◽  
Mayur Yergiri

An isocratic liquid chromatographic method with UV detection at 230 nm is described for simultaneous determination of ceftriaxone sodium and salbutamol in bulk. Chromatographic separation of the two drugs was achieved on an Inertsil ODS© C18 (250 × 4.6 mm, 5 μ) using a mobile phase consisting of 50 mM potassium dihydrogen orthophosphate and methanol (77:23 %V/V) adjusted to pH 7.0 with triethylamine at a fl ow rate of 1.0mL min-1. The optimum separation was achieved in less than 10 minutes. The developed liquid chromatographic method offers symmetric peak shape, good resolution and reasonable retention time for both drugs. The method was validated as per ICH guidelines.


Author(s):  
M. Murali ◽  
P. Venkateswara Rao

A simple, selective, linear, precise and accurate isocratic RP-HPLC method was developed and validated for rapid assay of Vandetanib, an anticancer drug, in both bulk and tablet dosage form. Elution at a flow rate of 1ml/min was employed on a symmetry C18 column at ambient temperature. The mobile phase consisted of acetonitrile, water and orthophosphoric acid in the ratio of 90:08:02 (v/v/v). Linearity was observed in concentration range of 50-200 ppm. The retention time for Vandetanib was 3.326 min. The method was validated as per the ICH guidelines. The proposed method can be successfully applied for the estimation of Vandetanib in pharmaceutical dosage forms. Moreover the detection alone was also verified through LC-MS of the Vandetanib drug using ESI method which provides future scope for study of this drug using LC-MS method also.


2021 ◽  
Author(s):  
Tam Nguyen ◽  
Laurien Menten ◽  
Isabel Spriet ◽  
Charlotte Quintens ◽  
Ann Van Schepdael ◽  
...  

Author(s):  
Avinash Birajdar ◽  
Varsha Tegeli ◽  
Suyash Ingale ◽  
Gajanand Nangare

A Reverse Phase High Performance Liquid Chromatographic method has been developed and validated for estimation of Ritonavir in API and Tablet formulation. The chromatographic separation was carried out using ZOROBAX Bonus-RP C-18 column (250 x 4.6mm, 5µm) as stationary phase and Methanol: Acetonitrile: 0.1% Trifluoroacetic acid water (81:9:10) as mobile phase at 1.0 ml/min flow rate and detection was carried out at 250 nm. The method was validated accordance to the Guidelines of International Council for Harmonization (ICH). Ritonavir have linearity in the concentration range of 50-150µg/ml with correlation coefficient (r2=1) respectively. Ritonavir eluted at 3.05 min respectively. The method is sensitive, precise and accurate. So, the method can be successfully applied for the routine analysis of Ritonavir in pharmaceutical formulations.


Author(s):  
Gunturu. Raviteja ◽  
Kantipudi Rambabu

Aims: New validated method for the estimation of Mobocertinib using HPLC and study of its degradation. Place and Duration of Study: Department of Chemistry, RVR & JC College of Engineering, Chowdavaram, Guntur, Andhra Pradesh, between February 2021 and August 2021. Methodology: Using an X-bridge phenyl column (150 mm x 4.6 mm, 3.5 µ), acetonitrile, and 0.1 percent ortho phosphoric acid (OPA) (60:40 v/v) as a mobile phase, the proposed method successfully achieved effective chromatographic separation with a flow rate of 1 mL/min and a wave length of 224 nm. Mobocertinib had a retention time of 2.271 minutes. The isocratic chromatography was performed at room temperature and took approximately five minutes to complete. Results: Analysis was achieved within 5 min over an honest linearity within the concentration range from 6-90 µg/ml of Mobocertinib. Using a mathematical process, the suitability parameters of the system were investigated, and the results were found to be in acceptable limits. In a linear analysis, stages with regression coefficients of 0.999 were used. LOD and LOQ values were 0.075μg/ml and 0.248 g/ml for Mobocertinib. The drug was recovered at a rate of 98-102 percent, which means that the recovery is within reasonable limits. Conclusion: The validation results were satisfactory, and the approach was found to be suitable for bulk and formulation analysis. The recommended procedure was found to be warranted according to ICH guidelines.


Sign in / Sign up

Export Citation Format

Share Document