Combined Use of Intraoperative DSA, Temporary Balloon Occlusion and Retrograde Suction Decompression Technique in Surgery for Complex Internal Carotid Artery Aneurysms

2015 ◽  
pp. 670-673
Author(s):  
Kazuo Mizoi ◽  
Takashi Yoshimoto ◽  
Akira Takahashi ◽  
Satoru Fujiwara ◽  
Keiji Koshu
2017 ◽  
Vol 14 (2) ◽  
pp. 32-35
Author(s):  
Saujanya Rajbhandari ◽  
Pravesh Rajbhandari ◽  
Pranaya Shrestha ◽  
Basant Pant ◽  
Anish Neupane

Balloon Test occlusion (BTO) is a preoperative angiographic test used to estimate the risk of stroke after permanent therapeutic occlusion of an internal carotid artery (ICA) involved by aneurysms. Temporary balloon occlusion at the cavernous ICA aneurysm neck was performed in an attempt to assess the adequacy of cross flow from the opposite ICA. Adequate fl ow following BTO are preferred to have simple ICA ligation and incase of those who did not pass BTO trapping and high flow bypass is preferred .We have done Right ICA Ligation on our case report.Nepal Journal of Neuroscience, Vol. 14, No. 2,  2017 Page:32-35


2001 ◽  
Vol 7 (4) ◽  
pp. 331-335 ◽  
Author(s):  
A. Uchino ◽  
Y. Takase ◽  
T. Koizumi ◽  
S. Kudo

We report a patient with a giant aneurysm on the left cervical internal carotid artery (ICA) treated successfully by proximal coil occlusion. Fibered platinum coils were delivered via a 5-F catheter under temporary balloon occlusion of the proximal ICA and without complications. MR imaging ten months after the procedure showed the aneurysm to be reduced in size and subtotally thrombosed. Retrograde partial filling of the aneurysmal lumen was present, however. We describe the case in detail and discuss the ideal treatment of the cervical ICA aneurysm.


2020 ◽  
Vol 13 (12) ◽  
pp. e237301
Author(s):  
Kartik D Bhatia ◽  
Heath French ◽  
Gemma Olsson ◽  
Krishna Tumuluri

Transorbital penetrating foreign bodies are extremely rare in children and may penetrate the cavernous sinus or the underlying internal carotid artery. Parent vessel sacrifice and temporary balloon occlusion are feasible options for managing arterial injury during removal of the foreign body. Even in the absence of arterial injury, the ophthalmologist may encounter significant bleeding from the cavernous sinus deep in their operative field that is difficult to control. We present a case of a 6-year-old child with a stick penetrating the left superior orbit to enter the cavernous sinus but sparing the internal carotid artery. We describe the first reported experience of prophylactic coil embolisation of the cavernous sinus to minimise intraoperative bleeding during transorbital removal of a foreign body with an excellent clinical outcome.


2019 ◽  
Vol 23 (2) ◽  
pp. 73
Author(s):  
D. U. Malaev ◽  
D. A. Redkin ◽  
V. I. Baystrukov ◽  
A. A. Prokhorikhin ◽  
A. A. Boykov ◽  
...  

<p>Despite the development of modern medical technologies, cerebrovascular disease remains a major health and social issue. Among all the cases of ischemic stroke, approximately 20% are attributable to stenotic lesions in the carotid artery. The main drawback of carotid stenting is the risk of embolic complications during the procedure. To resolve this problem, various devices that protect against embolism have been developed. In this clinical case, we describe the ability to minimize the risk of operative stroke through a combined application of the distal and proximal protection systems in carotid stenting.</p><p>In our patient, a 65-year-old woman, angiography of the carotid arteries revealed an ulcerated atherosclerotic plaque of the right internal carotid artery, with stenosis of the lumen of up to 95%. Considering the high risk of distal embolism, the Mo MaUltra (Italy) proximal protection system was used. When evaluating the installation of the Mo MaUltra system, the preserved blood flow through the superior thyroid artery and, therefore, the antegrade blood flow in the internal carotid artery was revealed. Considering the identified risk and the anatomy of the plaque surface, we decided on the additional use of the distal SpiderFX (USA) protection device.</p><p>The combined use of proximal protection system and distal protective device for carotid stenting is technically possible and may reduce the risk of embolic complications.</p><p>Received 23 January 2019. Revised 18 March 2019. Published 23 April 2019.</p><p><strong>Informed consent:</strong> The patient’s informed consent to use the records for medical purposes is obtained.</p><p><strong>Funding:</strong> The study did not have sponsorship.</p><p><strong>Conflict of interest:</strong> Authors declare no conflict of interest.</p>


Sign in / Sign up

Export Citation Format

Share Document