scholarly journals Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography

2018 ◽  
Vol 59 (3) ◽  
pp. 1554 ◽  
Author(s):  
Sunee Chansangpetch ◽  
Anwell Nguyen ◽  
Marta Mora ◽  
Mai Badr ◽  
Mingguang He ◽  
...  
Cornea ◽  
2015 ◽  
Vol 34 (11) ◽  
pp. 1413-1419 ◽  
Author(s):  
Johannes Steinberg ◽  
Maria K. Casagrande ◽  
Andreas Frings ◽  
Toam Katz ◽  
Vasyl Druchkiv ◽  
...  

2021 ◽  
Vol 10 (5) ◽  
pp. 1094
Author(s):  
Michał Dembski ◽  
Anna Nowińska ◽  
Klaudia Ulfik-Dembska ◽  
Edward Wylęgała

Background: The present study determined the mean reference values of the anterior segment parameters of the selected eye using swept source optical coherence tomography (SS-OCT) in healthy Caucasian participants. Methods: A total of 166 volunteers (age 54–79 years), women (n = 92) and men (n = 74), were analyzed. One eye of each subject was randomly selected for anterior segment imaging. The anterior segment of the eye was scanned with CASIA2. The analyzed anterior segment parameters were divided into three groups, namely parameters of the cornea, lens, and angle. Results: The OCT (e.g., Ks, Kf, pKf, pKs, and central corneal thickness) and Fourier parameters of the cornea were significantly different between females and males. The iridocorneal angle was the smallest in the upper quadrant for all distance from the apex of the angle (250, 500, and 750 µm). Conclusions: Therefore, SS-OCT enables the analysis of parameters of the cornea, anterior chamber, lens, and iridocorneal angle, highlighting its clinical utility. Sex-specific differences in the analyzed parameters should be taken into account during the diagnosis of corneal diseases. The configuration of the filtration angle is an important marker during glaucoma diagnosis and drainage implant surgery. Measurements with CASIA 2is characterized by very good repeatability.


2016 ◽  
Vol 2016 ◽  
pp. 1-8 ◽  
Author(s):  
Mohammed Rigi ◽  
Nicholas P. Bell ◽  
David A. Lee ◽  
Laura A. Baker ◽  
Alice Z. Chuang ◽  
...  

Purpose. To evaluate interobserver, intervisit, and interinstrument agreements for gonioscopy and Fourier domain anterior segment optical coherence tomography (FD ASOCT) for classifying open and narrow angle eyes. Methods. Eighty-six eyes with open or narrow anterior chamber angles were included. The superior angle was classified open or narrow by 2 of 5 glaucoma specialists using gonioscopy and imaged by FD ASOCT in the dark. The superior angle of each FD ASOCT image was graded as open or narrow by 2 masked readers. The same procedures were repeated within 6 months. Kappas for interobserver and intervisit agreements for each instrument and interinstrument agreements were calculated. Results. The mean age was 50.9 (±18.4) years. Interobserver agreements were moderate to good for both gonioscopy (0.57 and 0.69) and FD ASOCT (0.58 and 0.75). Intervisit agreements were moderate to excellent for both gonioscopy (0.53 to 0.86) and FD ASOCT (0.57 and 0.85). Interinstrument agreements were fair to good (0.34 to 0.63), with FD ASOCT classifying more angles as narrow than gonioscopy. Conclusions. Both gonioscopy and FD ASOCT examiners were internally consistent with similar interobserver and intervisit agreements for angle classification. Agreement between instruments was fair to good, with FD ASOCT classifying more angles as narrow than gonioscopy.


Cornea ◽  
2017 ◽  
Vol 36 (2) ◽  
pp. 183-188 ◽  
Author(s):  
Pedro Arriola-Villalobos ◽  
José Ignacio Fernández-Vigo ◽  
David Díaz-Valle ◽  
Jaime Almendral-Gómez ◽  
Cristina Fernández-Pérez ◽  
...  

2009 ◽  
Vol 35 (8) ◽  
pp. 1410-1414 ◽  
Author(s):  
Edward Wylęgała ◽  
Slawomir Teper ◽  
Anna K. Nowińska ◽  
Michal Milka ◽  
Dariusz Dobrowolski