scholarly journals Histologic Changes Following Continuous Wave and Micropulse Transscleral Cyclophotocoagulation: A Randomized Comparative Study

2020 ◽  
Vol 9 (5) ◽  
pp. 22 ◽  
Author(s):  
Kareem Moussa ◽  
Max Feinstein ◽  
Melike Pekmezci ◽  
Jun Hui Lee ◽  
Michele Bloomer ◽  
...  
2019 ◽  
Vol 30 (4) ◽  
pp. 700-705 ◽  
Author(s):  
Alexander T Nguyen ◽  
Jessica Maslin ◽  
Robert J Noecker

Purpose: To describe our clinical experience with the efficacy and safety of micropulse transscleral cyclophotocoagulation as a treatment for glaucoma. Methods: In this retrospective case series, we reviewed the charts of 95 consecutive patients with various glaucoma subtypes who underwent micropulse transscleral cyclophotocoagulation. Patients were offered micropulse transscleral cyclophotocoagulation if they had perimetric glaucoma refractory to intraocular pressure–lowering topical medications and who were poor candidates for traditional filtering surgery. Eligible patients were treated with the Micropulse P3 device (IQ 810 Laser Systems; Iridex, Mountain View, CA, USA) at 2.0–2.5 W for a duration of 90 s per hemisphere at a 31.3% duty cycle. If a retreatment was needed, the power was increased to up to 3.0 W with other parameters remaining the same. Patients were considered successfully treated if their intraocular pressure was lowered by at least 20% compared to their baseline. The main outcome measure was post-operative intraocular pressure; secondary outcome measures included the number of adverse events and complications that occurred with treatment. Results: The glaucoma subtypes treated included primary open-angle glaucoma (n = 51), exfoliation glaucoma (n = 24), chronic angle-closure glaucoma (n = 15), and congenital/juvenile glaucoma (n = 5). The mean pre-operative intraocular pressure was 25.1 ± 5.3 mm Hg and the mean post-operative intraocular pressure at 12 months was 17.5 ± 5.1 mm Hg (p = 0.004). The mean number of intraocular pressure–lowering medications used preoperatively was 3.0 ± 1.1; the mean number of medications used at the 12-month post-operative visit was 1.4 ± 1.0 (p = 0.03). Success with one treatment was achieved in 73 (76.8%) of patients. With multiple treatments, all patients had significant intraocular pressure–lowering compared to baseline. The maximum number of treatments received by any single patient was 5. There were no instances of prolonged intraocular inflammation or long-term hypotony. Conclusion: Micropulse transscleral cyclophotocoagulation appears to be a safe and efficacious treatment for glaucoma. Given its improved safety profile compared to continuous-wave transscleral cyclophotocoagulation, it deserves consideration as a primary procedure.


2021 ◽  
pp. bjophthalmol-2021-319757
Author(s):  
Mohamed M Khodeiry ◽  
Alison J Lauter ◽  
Mohamed S Sayed ◽  
Ying Han ◽  
Richard K Lee

AimsTo report treatment outcomes of slow-coagulation continuous-wave transscleral cyclophotocoagulation (TSCPC) as an initial surgical intervention in patients with neovascular glaucoma (NVG).MethodsA retrospective study including 53 patients (mean age of 69.6±16.6 years and mean follow-up of 12.7±8.9 months) with a diagnosis of NVG and no previous incisional glaucoma or cyclophotocoagulation surgeries. All patients underwent slow-coagulation continuous-wave TSCPC (1250-milliwatt power and 4-second duration).Primary outcome measure was surgical success defined as an intraocular pressure (IOP) from 6 to 21 mm Hg with a reduction ≥20% from baseline, no reoperation for glaucoma and no loss of light perception vision. Secondary outcome measures include IOP, glaucoma medications, visual acuity (VA) and complications.ResultsIOP decreased from 40.7±8.6 mm Hg preoperatively to 18.4±12.2 mm Hg postoperatively (p<0.001). The preoperative number of glaucoma medications dropped from 3.3±1.1 at baseline to 2.0±1.5 at the last postoperative visit (p<0.001). The cumulative probabilities of success at 12 and 24 months were 71.7% and 64.2 %, respectively. Mean logarithm of the minimum angle of resolution VA was relatively unchanged from 2.27±0.63 to 2.25±0.66 at the last follow-up visit (p=0.618). The most common observed complications were decrease in baseline VA (13.2%) and anterior chamber inflammation (9.4%).ConclusionsSlow-coagulation TSCPC is an effective and relatively safe initial surgical intervention in medically uncontrolled NVG.


2020 ◽  
Vol 55 (4) ◽  
pp. 330-335 ◽  
Author(s):  
Jessica S. Maslin ◽  
Peter P. Chen ◽  
John Sinard ◽  
Alexander T. Nguyen ◽  
Robert Noecker

2011 ◽  
Vol 19 (25) ◽  
pp. 25279 ◽  
Author(s):  
Venkatesan Jambunathan ◽  
Xavier Mateos ◽  
Maria Cinta Pujol ◽  
Joan Josep Carvajal ◽  
Francesc Díaz ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document