continuous wave
Recently Published Documents


TOTAL DOCUMENTS

10367
(FIVE YEARS 1874)

H-INDEX

120
(FIVE YEARS 15)

Author(s):  
Jawad Mirza ◽  
Salman Ghafoor ◽  
Anila Kousar ◽  
Benish Kanwal ◽  
Khurram Karim Qureshi

Sensors ◽  
2022 ◽  
Vol 22 (2) ◽  
pp. 649
Author(s):  
David Ferreira ◽  
Samuel Silva ◽  
Francisco Curado ◽  
António Teixeira

Speech is our most natural and efficient form of communication and offers a strong potential to improve how we interact with machines. However, speech communication can sometimes be limited by environmental (e.g., ambient noise), contextual (e.g., need for privacy), or health conditions (e.g., laryngectomy), preventing the consideration of audible speech. In this regard, silent speech interfaces (SSI) have been proposed as an alternative, considering technologies that do not require the production of acoustic signals (e.g., electromyography and video). Unfortunately, despite their plentitude, many still face limitations regarding their everyday use, e.g., being intrusive, non-portable, or raising technical (e.g., lighting conditions for video) or privacy concerns. In line with this necessity, this article explores the consideration of contactless continuous-wave radar to assess its potential for SSI development. A corpus of 13 European Portuguese words was acquired for four speakers and three of them enrolled in a second acquisition session, three months later. Regarding the speaker-dependent models, trained and tested with data from each speaker while using 5-fold cross-validation, average accuracies of 84.50% and 88.00% were respectively obtained from Bagging (BAG) and Linear Regression (LR) classifiers, respectively. Additionally, recognition accuracies of 81.79% and 81.80% were also, respectively, achieved for the session and speaker-independent experiments, establishing promising grounds for further exploring this technology towards silent speech recognition.


2022 ◽  
Vol 11 (1) ◽  
Author(s):  
Zhiyue Zhou ◽  
Zefeng Wang ◽  
Wei Huang ◽  
Yulong Cui ◽  
Hao Li ◽  
...  

AbstractFibre lasers operating at the mid-IR have attracted enormous interest due to the plethora of applications in defence, security, medicine, and so on. However, no continuous-wave (CW) fibre lasers beyond 4 μm based on rare-earth-doped fibres have been demonstrated thus far. Here, we report efficient mid-IR laser emission from HBr-filled silica hollow-core fibres (HCFs) for the first time. By pumping with a self-developed thulium-doped fibre amplifier seeded by several diode lasers over the range of 1940–1983 nm, narrow linewidth mid-IR emission from 3810 to 4496 nm has been achieved with a maximum laser power of about 500 mW and a slope efficiency of approximately 18%. To the best of our knowledge, the wavelength of 4496 nm with strong absorption in silica-based fibres is the longest emission wavelength from a CW fibre laser, and the span of 686 nm is also the largest tuning range achieved to date for any CW fibre laser. By further reducing the HCF transmission loss, increasing the pump power, improving the coupling efficiency, and optimizing the fibre length together with the pressure, the laser efficiency and output power are expected to increase significantly. This work opens new opportunities for broadly tunable high-power mid-IR fibre lasers, especially beyond 4 μm.


2022 ◽  
Vol 13 (1) ◽  
Author(s):  
Zhixin Wang ◽  
Filippos Kapsalidis ◽  
Ruijun Wang ◽  
Mattias Beck ◽  
Jérôme Faist

AbstractSemiconductor lasers with extremely low threshold power require a combination of small volume active region with high-quality-factor cavities. For ridge lasers with highly reflective coatings, an ultra-low threshold demands significantly suppressing the diffraction loss at the facets of the laser. Here, we demonstrate that introducing a subwavelength aperture in the metallic highly reflective coating of a laser can correct the phase front, thereby counter-intuitively enhancing both its modal reflectivity and transmissivity at the same time. Theoretical and experimental results manifest a decreasing in the mirror loss by over 40% and an increasing in the transmissivity by 104. Implementing this method on a small-cavity quantum cascade laser, room-temperature continuous-wave lasing operation at 4.5 μm wavelength with an electrical consumption power of only 143 mW is achieved. Our work suggests possibilities for future portable applications and can be implemented in a broad range of optoelectronic systems.


2022 ◽  
Vol 14 (2) ◽  
pp. 294
Author(s):  
Shuo Li ◽  
Jieqiong Ding ◽  
Weirong Liu ◽  
Heng Li ◽  
Feng Zhou ◽  
...  

The track settlement has a great influence on the safe operation of high-speed trains. The existing track settlement measurement approach requires sophisticated or expensive equipments, and the real-time performance is limited. To address the issue, an ultra-high resolution track settlement detection method is proposed by using millimeter wave radar based on frequency modulated continuous wave (FMCW). Firstly, by constructing the RCS statistical feature data set of multiple objects in the track settlement measurement environment, a directed acyclic graph-support vector machine (DAG-SVM) based method is designed to solve the problem of track recognition in multi-object scenes. Then, the adaptive chirp-z-transform (ACZT) algorithm is used to estimate the distance between the radar and the track surface, which realizes automatic real-time track settlement detection. An experimental platform has been constructed to verify the effectiveness of the proposed method. The experimental results show that the accuracy of track classification and identification is at least 95%, and the accuracy of track settlement measurement exceeds 0.5 mm, which completely meets the accuracy requirements of the railway system.


Author(s):  
Salvador Gutierrez-Portocarrero ◽  
Pradeep Subedi ◽  
Mario A. Alpuche-Aviles

Abstract Temperature dependence studies of electrochemical parameters provide insight into electron transfer processes. In cases where adding excess electrolyte experimental causes complications colloidal systems, organic or biological samples it is preferable to deal with the high resistivity of the medium. We validate the use of unsupported and weakly supported solutions in thermoelectrochemical experiments. The temperature dependence of the diffusion coefficient allows calibration of the steady-state current to measure changes when a continuous wave (CW) ultraviolet laser, λ=325 nm, illuminates an ultramicroelectrode (UME) from the front. Calibrating the steady-state current ratios before and after heating with a thermostatic bath allows temperature measurements within an accuracy of 0.6 K. The solutions are without supporting electrolytes in methanol, a volatile solvent, and we use a model that accurately describes the viscosity and temperature dependence of the solvent. We calculated the temperature and derived an equation to estimate the temperature measurement error. A numeric method yields satisfactory results, considering the changes for both diffusion coefficients and viscosity explicitly, and predict the thermostatic temperature bath, agreeing with the theoretical model's error. In unsupported solutions, the ferrocene diffusion coefficient and the iodide apparent diffusion coefficient follow the expected increase with temperature. Under CW laser illumination ΔT=4±1 K.


2022 ◽  
Vol 23 (2) ◽  
pp. 658
Author(s):  
Alexandre Joushomme ◽  
André Garenne ◽  
Mélody Dufossée ◽  
Rémy Renom ◽  
Hermanus Johannes Ruigrok ◽  
...  

It remains controversial whether exposure to environmental radiofrequency signals (RF) impacts cell status or response to cellular stress such as apoptosis or autophagy. We used two label-free techniques, cellular impedancemetry and Digital Holographic Microscopy (DHM), to assess the overall cellular response during RF exposure alone, or during co-exposure to RF and chemical treatments known to induce either apoptosis or autophagy. Two human cell lines (SH-SY5Y and HCT116) and two cultures of primary rat cortex cells (astrocytes and co-culture of neurons and glial cells) were exposed to RF using an 1800 MHz carrier wave modulated with various environmental signals (GSM: Global System for Mobile Communications, 2G signal), UMTS (Universal Mobile Telecommunications System, 3G signal), LTE (Long-Term Evolution, 4G signal, and Wi-Fi) or unmodulated RF (continuous wave, CW). The specific absorption rates (S.A.R.) used were 1.5 and 6 W/kg during DHM experiments and ranged from 5 to 24 W/kg during the recording of cellular impedance. Cells were continuously exposed for three to five consecutive days while the temporal phenotypic signature of cells behavior was recorded at constant temperature. Statistical analysis of the results does not indicate that RF-EMF exposure impacted the global behavior of healthy, apoptotic, or autophagic cells, even at S.A.R. levels higher than the guidelines, provided that the temperature was kept constant.


Author(s):  
Yangyu Liu ◽  
Xue Cao ◽  
AnHua Xian ◽  
Guangmiao Liu ◽  
Wei zhou ◽  
...  

Abstract We demonstrate stable continuous-wave mode-locking (CWML) pulses around 1645nm by employing the home-made Er:YAG ceramic. By using a fiber laser and semiconductor saturable absorber mirror (SESAM) with modulation depth of 1.2%, we get ML pulses with the output average power up to 815 mW, the pulse width shortened as ~4 ps, and the peak power of 1.8 kW. With the SESAM of modulation depth of 2.4%, the second-order harmonic ML pulses were also obtained. As far as we know, this is the first report of CWML from Er3+-doped ceramics and also the shortest pulse duration in Er3+-doped solid-state oscillators.


Sign in / Sign up

Export Citation Format

Share Document