Comparison of in vivo vs. in vitro Bonding of Composite Resin to the Dentin of Canine Teeth

1988 ◽  
Vol 67 (2) ◽  
pp. 467-470 ◽  
Author(s):  
E.L. Pashley ◽  
L. Tao ◽  
J.R. Mackert ◽  
D.H. Pashlety

Dogs were utilized in a study to compare the bond strengths of dentin bonding agents made to dentin in vivo and then again in vitro in the same teeth 30 min, one day, one week, and one month post-extraction. No statistically significant differences were observed between bonds made in vivo and those made in vitro at any time period. Contamination of the dentin surfaces with blood or saliva lowered the bond strengths, but these could be restored to control values by re-surfacing of the dentin with a bur.

2012 ◽  
Vol 06 (02) ◽  
pp. 115-122 ◽  
Author(s):  
Bengi Oztas ◽  
Sebnem Kursun ◽  
Gul Dinc ◽  
Kıvanc Kamburoglu

ABSTRACTObjective: The purpose of this in vitro study was to explore the radiopacity of composite resins and bonding materials using film and phosphor plates.Methods: Nine composite dental resin specimens and human tooth slices were exposed together with an aluminium stepwedge using dental film and phosphor plates. Eight dentin bonding specimens were prepared and exposed in a similar manner. Their radiopacity on film was assessed using a transmission densitometer, and the radiopacity with phosphor plates was assessed digitally using the system’s own software (Digora). Data were analysed using one-way analysis of variance (ANOVA) and post-hoc Tukey tests (P<.05). Film and phosphor plate radiopacity values were compared using simple regression analysisResults: Excellent linear correlation was found between film and phosphor plates for both composite resins and bonding agents. The composite materials Spectrum Tph and Natural Look exhibited the highest radiopacity with film and with phosphor plates, respectively. All the dentin bonding agents tested exhibited lower radiopacity than dentin. Conclusion: Synergy, Ice, Filtek Silorane, Filtek Z250, Clearfil Majesty Posterior, Herculite Classic, Spectrum Tph, and Natural Look composite materials exhibited greater radiopacity than dentin, and all the dentin bonding agents tested exhibited lower radiopacity than either enamel or dentin. (Eur J Dent 2012;6:115-122)


2010 ◽  
Vol 36 (11) ◽  
pp. 1844-1850 ◽  
Author(s):  
Na Ryoung Kim ◽  
Hee Chul Park ◽  
Insook Kim ◽  
Bum-Soon Lim ◽  
Hyeong-Cheol Yang

2008 ◽  
Vol 28 (10) ◽  
pp. 971-975
Author(s):  
E. Koliniotou-Koubia ◽  
P. Dionysopoulos ◽  
E. A. Koulaouzidou ◽  
A. H. Kortsaris ◽  
Y. Papadogiannis

Sign in / Sign up

Export Citation Format

Share Document