Obturator foramen bypass for infective groin caused by closure device

2016 ◽  
Vol 25 (2) ◽  
pp. 131-133
Author(s):  
Yoshihito Irie ◽  
Shunichi Kondo ◽  
Kyu Rokkaku ◽  
Eitoshi Tsuboi ◽  
Hiroshi Takano ◽  
...  

A 69-year-old man underwent carotid artery stenting through the right femoral artery with a percutaneous vascular closure device for hemostasis. Eleven days later, an infective femoral artery pseudoaneurysm was diagnosed by computed tomography. At surgery, a defect in the femoral artery was observed, corresponding to the remnants of the closure device. Removal of the foreign material, debridement, wound irrigation, and arterial patch plasty were performed, but the infection and leg ischemia did not improve. After several failed attempts to revascularize and control the infection, obturator foramen bypass was performed. The postoperative course was uneventful, indicating the usefulness of this procedure.

2009 ◽  
Vol 20 (12) ◽  
pp. 1639-1640 ◽  
Author(s):  
Ding-Cheng Xiang ◽  
William B. Hillegass ◽  
Guo-xin Luo ◽  
Jian-xin He

2021 ◽  
Vol 4 (1) ◽  
Author(s):  
Mohammed Shamseldin ◽  
Hendrik Bergert ◽  
Axel Neumeister ◽  
Ralf Puls

Abstract Background This is a rare case of removing an intra-arterial foreign body represented by MynxGrip polyethylene glycol (PEG) sealant as a rare complication of using the MynxGrip™ Vascular Closure Device (AccessClosure, Inc., Mountain View, CA) using a pRESET stent retriever (Phenox, Bochum, Germany) which is utilized mainly for treatment of endovascular stroke. Case presentation A 60-year-old female patient suffering from intermittent claudication in the right lower limb (stage IIb according to Fontaine) due to a peripheral arterial occlusive disease was presented for an elective revascularization using balloon angioplasty of a short chronic occlusion of the right superficial femoral artery. After a successful revascularization of the right superficial femoral artery using a retrograde femoral access from the left common femoral artery, the patient suffered from an acute limb ischemia in the left foot with distal popliteal embolization with involvement of BTK (below the knee) trifurcation. This is believed to be due to an intra-arterial foreign body embolism of MynxGrip polyethylene glycol sealant as a rare complication of using the MynxGrip™ Vascular Closure Device. Conclusions Stent retrievers have been used previously in removing dislocated coils especially in the cerebral vessels. This case report however proves a high efficacy and safety of using stent retrievers in removing different and rather unusual intra-arterial foreign bodies such as MynxGrip polyethylene glycol sealant.


2020 ◽  
Vol 29 (3) ◽  
pp. 71-79
Author(s):  
Yu.V. Cherednichenko

One case of successful treatment of the common femoral artery pseudoaneurysm with usage of modified technique of pseudoaneurysm neck sealing with Angio-Seal with retrograde access percutaneously is presented.A 52-year-old man was admitted in the recovery period of ischemic stroke in the left carotid basin. A total subtraction cerebral angiography was performed, which revealed severe stenosis in the bulb of the left internal carotid artery with ulcerated contour and severe stenosis in the ostium of the left vertebral artery. Hemostasis was performed by compression. A pressure dressing was applied for a day. The puncture site was without any problems on the next day. The patient received double antiplatelet therapy 5 days before endovascular surgery. Before surgery, palpation in the right inguinal region determines a rounded painful compaction. Carotid stenting on the left side, stenting of the left vertebral artery and control angiography of arteries of the right lower limb were performed by left-side femoral access. Pseudoaneurysm in the bifurcation of the right common femoral artery with a narrow neck was verified. Attempts to cure it by manual compression under angiographic control and ultrasound control were unsuccessful.After 6 days, endovascular treatment of pseudoaneurysms of the right common femoral artery with closure of the pseudoaneurysm neck was performed. The right common femoral artery was catheterized with left radial access with diagnostic catheter on a hydrophilic wire 0.035ʺ. This wire was carefully advanced into pseudoaneurysm through a defect in the common femoral artery and subsequently served as a marker. The pseudoaneurysm was punctured with miniaccess needle, then the 0.018ʺ wire passed through the pseudoaneurysm neck into the femoral artery retrogradly, focusing on the “marker” wire. A 6F radial introducer is introduced along 0.018ʺ wire. Further, this access was used to close the pseudoaneurysm neck with the Angio-Seal Closure Device 6F according to the standard method. In a control angiograms, a pseudoaneurysm did not contrast, arteries are passable without stenosis and signs of dissection. Hemostasis at the site of puncture of the radial artery was performed with a hemostatic bracelet. The patient was discharged from the clinic to continue treatment in a rehabilitation neurological center.This technique of endovascular treatment of postcatheterization pseudoaneurysms of the common femoral artery is quite simple, causing minimal discomfort for the patient. The closure is immediate and angiographically controled. The use of radial access instead of contralateral femoral access for introducing of a “marker” wire and angiographic control reduces the risk of local complications at the access site.


2002 ◽  
Vol 9 (5) ◽  
pp. 703-706 ◽  
Author(s):  
Saim Yilmaz ◽  
Timur Sindel ◽  
Abdullah Erdoğan ◽  
Atalay Mete ◽  
Ersin Lüleci

Purpose: To present a case of extensive thigh hematoma that developed after use of a percutaneous suturing device for retrograde popliteal artery puncture. Case Report: A 55-year-old woman underwent endovascular treatment for a short occlusion of the right superficial femoral artery via a retrograde popliteal approach, after which the puncture site was closed with a Closer suture-mediated device. Several hours later, massive hematoma of the right thigh developed, which was noticed only after the patient's leg became markedly swollen and hypotension developed. Conclusions: The use of a suture-mediated closure device for a retrograde popliteal artery puncture may not be recommended.


2012 ◽  
Vol 19 (6) ◽  
pp. 836-843 ◽  
Author(s):  
Daniel Maxien ◽  
Barbara Behrends ◽  
Karla M. Eberhardt ◽  
Tobias Saam ◽  
Sven F. Thieme ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document