Background Intracranial aneurysm with endovascular treatment needs to be followed-up with a proper imaging method. Purpose To evaluate the performance of magnetic resonance angiography (MRA) with zero echo time at 1.5-T in assessing the intracranial aneurysm remnant and in-stent lumen as compared with time-of-flight MRA, with digital subtraction angiography as the gold standard. Material and Methods A total of 46 patients (17 men; mean age = 56.6±13.7 years) with 54 aneurysms who underwent coil embolization with or without stent were enrolled in this study. The presence of aneurysm remnant and the visualization of in-stent lumen were evaluated. The agreement of remnant identification between MRA with zero echo time and time-of-flight MRA with digital subtraction angiography was evaluated using Cohen’s kappa analysis. The performance of in-stent lumen visualization between MRA with zero echo time and time-of-flight MR angiography was compared with Chi-square test. Results Of 54 aneurysms, 27 were found to have remnants by digital subtraction angiography. The kappa value in identification of remnant of aneurysm was 0.852 between MRA with zero echo time and digital subtraction angiography and 0.741 between time-of-flight MRA and digital subtraction angiography. In detecting remnant of aneurysm, the sensitivity, specificity, positive predictive value, and negative predictive value were 96.3%, 88.9%, 89.7%, and 96.0% for MRA with zero echo time and 91.7%, 83.3%, 81.5%, and 92.6% for time-of-flight MRA, respectively. In visualizing in-stent lumen, MRA with zero echo time had better performance than time-of-flight MRA ( P < 0.001). Conclusion MR angiography with zero echo time might be a better non-invasive approach in assessing remnant of aneurysms and in-stent lumen as compared with time-of-flight MRA.

2004 ◽  
Vol 182 (1) ◽  
pp. 183-190 ◽  
Author(s):  
Kyo Noguchi ◽  
Elias R. Melhem ◽  
Tadayoshi Kanazawa ◽  
Michiya Kubo ◽  
Naoya Kuwayama ◽  
...  

2009 ◽  
Vol 72 (3) ◽  
pp. 365-369 ◽  
Author(s):  
Jean-Christophe Ferré ◽  
Béatrice Carsin-Nicol ◽  
Xavier Morandi ◽  
Michel Carsin ◽  
Axel de Kersaint-Gilly ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document