scholarly journals Minimally invasive plate osteosynthesis for the treatment of sternal fracture in the lower chest: a case report

2019 ◽  
Vol 47 (8) ◽  
pp. 4033-4038
Author(s):  
Ze-Xin Xie ◽  
Xue-Tao Zhou ◽  
Dong-Sheng Zhang ◽  
Yang Yang ◽  
Guo-Liang Zhang ◽  
...  

Sternal fracture is a common complication of chest trauma but has a low incidence. Various treatments have been developed to reconstruct sternal fractures. Among these approaches, analgesia, corset fixation, and open reduction with plate internal fixation have been suggested. The use of newly developed minimally invasive plate osteosynthesis is a feasible method. In this study, we report a case involving a 54-year-old man with a sternal fracture accompanied by bilateral pleural effusion and a small amount of right-sided pneumothorax. The patient was treated with minimally invasive plate osteosynthesis. The operation was successful and the postoperative recovery was good. No pneumothorax or complications such as chest pain, paresthesia, or wound infection were observed at the 1-year follow-up visit. Additionally, the bilateral pleural effusion had been completely absorbed. The incision in the lower chest was aesthetic and minimally traumatic. This case describes a novel method for internal fixation of sternal fractures.

2017 ◽  
Vol 17 (2) ◽  
pp. 18-22
Author(s):  
Nabees Man Singh Pradhan ◽  
JA Khan ◽  
B Acharya ◽  
S Shrestha ◽  
R Tamrakar ◽  
...  

Introduction: Distal tibial fractures present as a major challenge for the orthopedic trauma surgeons. Most non-operative treatments result in non-union or malunion and needs prolonged immobilization of the knee and ankle joints, with resulting stiffness. Open reduction and internal fixation as well as external fixation has high rate of infection and non-union. Minimally Invasive Plate Osteosynthesis has been shown to have a better outcome and has been the procedure of choice in most distal tibial fractures since the introduction of the locking compression plate. The objective of the study is to review the outcome of Minimally Invasive Percutaneous Osteosynthesis (MIPO) in unstable distal tibial fractures.Methods: Charts of patients who underwent MIPO from the year 2008 to 2013 for unstable distal tibial fractures over five years at Patan Hospital and Om Hospital were reviewed. All displaced closed fractures and Gustillo Anderson Type I and II fractures were included in the study. Plates consisted of the anatomically contoured 4.5 mm LCP and 3.5 mm LCP-Pilon form plate. A simple uniplanar external fixator was used to retain the reduction till the plate was inserted and secured with locking screws. The outcome of MIPO in distal tibial fractures were followed up and evaluated.  Clinical and radiological assessments were performed at 6 weeks, and at 3, 6, 9, 12 and 24 months.Results: Of the 75 patients (45 male, 30 female) age ranging from 19 to 70 years (mean 47 years), 5 patients were lost to follow-up. 28 patients at 3 months, 32 at 6 months, and 8 at 9 months met the criteria for a healed fracture. Two patients required autologous bone grafting at 9 months for non-union ultimately resulting in the fracture union at 16 months. There was one malunion attributable to the loss of reduction during plate fixation. There were no deep infections, no soft tissue complications and no failures of fixation. The cause of fracture were RTA (n=35), fall from height (n=9), twisting of ankle as a result of fall from standing height (n=22), and others (n=11). The mean time for surgery from the time of injury was 5 (range, 2 to 14) days; the mean hospital stay was 10 (range, 7 to 21) days.Conclusion: MIPO is an effective treatment for closed, unstable fractures of the distal tibia, avoiding the complications associated with more traditional methods of internal fixation and/or external fixation.Journal of Society of Surgeons of NepalVol. 17, No. 2, 2014, Page: 7-11


Author(s):  
Abhishek Kumar ◽  
Rahul Bade

<p class="abstract"><strong>Background:</strong> Shaft of humerus (SOH) fracture has been conventionally treated with either open reduction internal fixation with plate osteosynthesis or immobilization as conservative treatment. Intramedullary interlocking nailing (IMIL) and anterior bridge plating (ABP) are both newer modalities of internal fixation for SOH fracture. Rotator cuff irritation is a known complication of IMIL nailing of the humerus. Here, we present clinical, radiological, and functional outcome of SOH fracture fixation by ABP using a minimally invasive method.</p><p class="abstract"><strong>Methods:</strong> Thirty patients with SOH fracture were treated surgically via an anterior minimally invasive plate osteosynthesis (MIPO) approach with ABP. There were 21 male and 9 female patients, and the average age was 38.6±10.45 years. The mechanism of injury was road traffic accidents (60%) and ground level fall (40%). Functional assessments were obtained with University of California at Los Angeles (UCLA) score and mayo elbow performance index (MEPI) during the follow-up period.<strong></strong></p><p class="abstract"><strong>Results:</strong> At the end of 6 months follow-up, 29 (96.7%) patients had excellent to good UCLA and MEPI scores. Varus/valgus angulation was reported in 4 (13.3%) patients. Two patients (6.7%) had radial nerve neuropraxia and delayed union, while 1 (3.3%) patient had screw back-out or loosening. The mean duration of radiation exposure was 178±41.2 seconds. ABP for SOH fractures is a safe and effective treatment modality.</p><p class="abstract"><strong>Conclusions:</strong> This treatment protocol produces high rates of union, excellent functional recovery, and minimal biological disruption.</p>


Author(s):  
Naveen Kumar ◽  
Manoj Thakur ◽  
Sandeep Kashyap

<p class="abstract"><strong>Background:</strong> The present study is an attempt to evaluate the results of locking compression plate for distal tibia in lower tibial fractures using open reduction internal fixation and minimally invasive plate osteosynthesis technique.</p><p class="abstract"><strong>Methods: </strong>Prospective and retrospective study was conduct on patients attending the outpatient department (OPD)/Emergency OPD in Indira Gandhi Medical College, Shimla during September 2015 to August 2016 with distal tibial fractures. The patients treated with locking compression plates using minimally invasive plate osteosynthesis (MIPO) or open reduction internal fixation (ORIF) are reviewed for inclusion and exclusion criteria. All data were collected and analyzed by Epi-info software.</p><p class="abstract"><strong>Results: </strong>Out of 52 patients, 48.4% patients undergo open reduction internal fixation had excellent results and 28.6% patients undergo surgery by MIPPO technique had excellent results. p value is 0.352 which is not significant. Overall, 40.4% patients had excellent results. In our study, 32.6% patients having AO/OTA type A fractures had excellent score while type B and C had 1.9% excellent score. This is attributed to more comminution and involvement of ankle joint. Overall, 40.4% patients had excellent score. P value is 0.863 which is insignificant.</p><p class="abstract"><strong>Conclusions: </strong>We observed excellent/ good functional outcome in 65.3% of patients.</p>


Sign in / Sign up

Export Citation Format

Share Document