Strut remodeling with hypercompliant balloon: A new approach to Y stent-assisted coil embolization in the treatment of complex wide-neck bifurcation aneurysms

2020 ◽  
pp. 159101992098433
Author(s):  
Ali Burak Binboga ◽  
Mehmet Onay ◽  
Cetin Murat Altay

Background The objective of this study was to present the long-term safety and effectiveness of strand remodelling with a hypercompliant balloon. Methods Patients with complex wide-neck bifurcation aneurysms (WNBAs) who underwent strand remodelling with a hypercompliant balloon via Y-stent-assisted coil embolization (Y-SACE) between September 2016 and January 2020 were included in the study. The feasibility, safety, effectiveness, and complication rates of the strand remodelling technique were investigated. Results A total of 12 patients (6 females, 6 males) were included in this study. Significant expansion was obtained in the intersection zone after remodelling. No regression was observed in the expansion rates during follow-up. There was no additional morbidity or mortality. No delayed thromboembolic complications occurred in our patients during long-term follow-up. Conclusions Performing strand remodelling to reduce thromboembolic complications triggered by structural faults caused by the Y-stent configuration is feasible, safe, and effective. This new approach can aid in the prevention of thromboembolic complications in Y-SACE.

2015 ◽  
Vol 8 (6) ◽  
pp. 581-585 ◽  
Author(s):  
Anna Luisa Kühn ◽  
Samuel Y Hou ◽  
Ajit S Puri ◽  
Christine F Silva ◽  
Matthew J Gounis ◽  
...  

BackgroundStent-assisted coil embolization (SACE) is a viable therapeutic approach for wide-neck intracranial aneurysms. However, it can be technically challenging in small cerebral vessels (≤2 mm).ObjectiveTo present our experience with stents approved for SACE in aneurysms with small parent arteries.MethodsAll patients who underwent stent-assisted aneurysm treatment with either a Neuroform or an Enterprise stent device at our institution between June 2006 and October 2012 were identified. Additionally, we evaluated each patient's vascular risk factors, aneurysm characteristics (ruptured vs non-ruptured, incidental finding, recanalized) and follow-up angiography data.ResultsA total of 41 patients with 44 aneurysms met our criteria, including 31 women and 10 men. Most of the aneurysms were located in the anterior circulation (75%). Stent placement in vessels 1.2–2 mm in diameter was successful in 93.2%. Thromboembolic complications occurred in 6 cases and vessel straightening was seen in 1 case only. Initial nearly complete to complete aneurysm obliteration was achieved in 88.6%. Six-month follow-up angiography showed coil compaction in three cases, one asymptomatic in-stent stenosis and stent occlusion. Twelve to 20-months’ follow-up showed stable coil compaction in two patients compared with previous follow-up, and aneurysm recanalization in two patients. Twenty-four to 36-months’ follow-up showed further coil compaction in one of these patients and aneurysm recanalization in a previous case of stable coil compaction on mid-term follow-up.ConclusionsOur results suggest that SACE of aneurysms with small parent vessels is feasible in selected cases and shows good long-term patency rates of parent arteries.


2020 ◽  
Author(s):  
Hadi Rokni Yazdi ◽  
Niloofar Ayoobi Yazdi ◽  
Mohammad Mehdi Mehrabinejad ◽  
Habibollah Dashti ◽  
Morteza Ghassed ◽  
...  

2001 ◽  
Vol 7 (1_suppl) ◽  
pp. 149-154 ◽  
Author(s):  
Y. Kaku ◽  
K. Hayashi ◽  
M. Sawada ◽  
N. Sakai

We evaluated long-term angiographical follow-up of cerebral aneurysms treated with detachable platinum coils with special reference to the long-term morphological outcomes of incompletely obliterated aneurysms. Serial long-term follow-up cerebral angiograms (>1 year) were obtained in 47 cases out of 134 cases treated with GDCs or IDCs from 1994 to 1999. In 47 patients, intial angiographical results demonstrated ten complete aneurysmal occlusion, seven aneurysms with a small neck remnant, twenty aneurysms with body filling and ten aneurysms with both of neck remnant and body filling. In the ten completely obliterated aneurysms, follow-up angiograms revealed no aneurysmal recanalization. In seven aneurysms with neck remnant, three remained unchanged, four showed enlargement of contrast filling in the part of the neck of the aneurysm. In twenty aneurysms with body filling, five had developed into complete obliteration, three remained unchanged, 11 had recanalization, and one aneurysm displayed regrowth. In ten aneurysms with both of neck remnant and body filling, two remained unchanged, five had recanalization, and three aneurysms displayed regrowth. Long-term angiographical follow-up results are less satisfactory in cases involving incompletely obliterated lesions. A higher incidence of recanalizations were promoted in cases with neck remnant and/or body filling. Strict follow-up angiography is mandatory when a complete obliteration is not achieved.


2022 ◽  
Vol 58 (1) ◽  
pp. 7-16
Author(s):  
Claudio Motta ◽  
Philip Witte ◽  
Andrew Craig

ABSTRACT The objective of this study was to document the short- and medium-to-long-term outcomes and complication rates of Y-T humeral condylar fractures fixed using titanium polyaxial locking plate (T-PLP). A retrospective review was performed of the medical records and radiographs of dogs with a Y-T humeral condylar fracture treated with T-PLP at a single veterinary referral center (2012–2018). Seventeen cases met the inclusion criteria. Medium- to long-term follow-up (.6 mo) information was derived using the Liverpool Osteoarthritis in Dogs (LOAD) questionnaire. Recorded complications were catastrophic (1/17) and minor (2/17). Gait at 10–12 wk following surgery was subjectively assessed as good or excellent for 13 cases. Radiographic bone union was achieved in 7/12 cases at 4–6 wk. LOAD scores obtained a mean of 15 mo (range 6–29 mo) following surgery and indicated no or mild impairment in 15/16 and moderate functional impairment in 1. The application of T-PLP for the treatment of Y-T humeral condylar fractures resulted in adequate stabilization allowing successful fracture healing and medium- to long-term outcomes comparable to previous reports. According to results of LOAD testing, the medium- to long-term follow-up suggests that clients were aware of mild to moderate functional impairment in all cases.


2018 ◽  
Vol 11 (5) ◽  
pp. 516-522 ◽  
Author(s):  
Idriss Haffaf ◽  
Frédéric Clarençon ◽  
Eimad Shotar ◽  
Claudia Rolla-Bigliani ◽  
Saskia Vande Perre ◽  
...  

Background and purposeThe Medina embolization device (MED) is a new flow disruption device combining the design of a detachable coil with an intrasaccular flow disrupter. Safety and short-term angiographic effectiveness of this device have recently been reported. However, long-term angiographic results are lacking. We report herein the 18 months’ angiographic outcome in patients treated for a wide-neck intracranial aneurysm with the MED.Materials and methodsNineteen patients (17 female, mean age 50 years) with 20 wide-neck intracranial aneurysms (six ruptured; 14 unruptured) were treated by the MED between January 2015 and June 2016. Procedure-related complications were systematically recorded; discharge and 6–9 months' follow-up modified Rankin Scale scores were assessed. Angiographic mid-term and long-term follow-up were performed with a mean delay of 6.4±1.5 months (n=16 aneurysms) and 17.7±4.2 months (n=15 aneurysms), respectively. Occlusion rates were evaluated after the procedure and at the mid-term and long-term follow-up using the Roy-Raymond scale.ResultsEmbolization with the MED was feasible in all except two cases (2/20, 10%). One per-procedural perforation was recorded (1/20, 5%) and one MED deployment failed because of the aneurysm’s shape (1/20, 5%). Three cases of thromboembolic complications were observed (3/20, 15%). Only one thromboembolic complication was responsible for clinical sequelae. Grade A occlusion rate was 61% (11/18) after the procedure, 75% at 6 months' follow-up (12/16), and 80% (12/15) at long-term follow-up. Two cases (2/18, 11%) of recanalization at mid-term were documented angiographically. No recanalization occurred between the mid-term and long-term follow-up.ConclusionMED is a hybrid embolization device, combining properties of a conventional coil with those of an intrasaccular flow disrupter. Our series focusing on long-term angiographic follow-up shows a satisfactory long-term occlusion rate. Larger series with longer angiographic follow-up times are warranted to confirm these preliminary results.


2017 ◽  
Vol 59 (6) ◽  
pp. 619-624 ◽  
Author(s):  
Boris Lubicz ◽  
Ricardo Morais ◽  
Pierre-Julien Bruyère ◽  
Noémie Ligot ◽  
Benjamin Mine

2018 ◽  
Vol 129 (6) ◽  
pp. 1492-1498 ◽  
Author(s):  
Masaomi Koyanagi ◽  
Akira Ishii ◽  
Hirotoshi Imamura ◽  
Tetsu Satow ◽  
Kazumichi Yoshida ◽  
...  

OBJECTIVELong-term follow-up results of the treatment of unruptured intracranial aneurysms (UIAs) by means of coil embolization remain unclear. The aim of this study was to analyze the frequency of rupture, retreatment, stroke, and death in patients with coiled UIAs who were followed for up to 20 years at multiple stroke centers.METHODSThe authors retrospectively analyzed data from cases in which patients underwent coil embolization between 1995 and 2004 at 4 stroke centers. In collecting the late (≥ 1 year) follow-up data, postal questionnaires were used to assess whether patients had experienced rupture or retreatment of a coiled aneurysm or any stroke or had died.RESULTSOverall, 184 patients with 188 UIAs were included. The median follow-up period was 12 years (interquartile range 11–13 years, maximum 20 years). A total of 152 UIAs (81%) were followed for more than 10 years. The incidence of rupture was 2 in 2122 aneurysm-years (annual rupture rate 0.09%). Nine of the 188 patients with coiled UIAs (4.8%) underwent additional treatment. In 5 of these 9 cases, the first retreatment was performed more than 5 years after the initial treatment. Large aneurysms were significantly more likely to require retreatment. Nine strokes occurred over the 2122 aneurysm-years. Seventeen patients died in this cohort.CONCLUSIONSThis study demonstrates a low risk of rupture of coiled UIAs with long-term follow-up periods of up to 20 years. This suggests that coiling of UIAs could prevent rupture for a long period of time. However, large aneurysms might need to be followed for a longer time.


Sign in / Sign up

Export Citation Format

Share Document