Corrective distal radius osteotomy following fracture malunion using a fixed-angle volar locking plate

2013 ◽  
Vol 39 (4) ◽  
pp. 431-435 ◽  
Author(s):  
S. Opel ◽  
S. Konan ◽  
E. Sorene

Post-traumatic distal radius deformity may cause severe morbidity, and corrective osteotomy is often necessary to realign the functional axis of the wrist to correct symptomatic malunion. The aim of this retrospective study was to review the short-term results of a single surgeon’s series of distal radius corrective osteotomies following fracture malunion using a fixed-angle volar locking plate for 20 patients (26 women) of an average age of 57 (range 19–83) years. At short-term follow up (average 14 months, range 12–15 months), no complications were noted and radiological union was confirmed in all cases at an average of 3 months. The average post-operative Disability of the Arm, Shoulder and Hand score was 13.48 (range 0–48.33) and an objective improvement was noted in movements at the wrist joint. A statistically significant improvement was achieved in ulnar variance, radial inclination, dorsal tilt, and supination.

Hand Surgery ◽  
2007 ◽  
Vol 12 (03) ◽  
pp. 183-190 ◽  
Author(s):  
Denju Osada ◽  
Shuzo Kamei ◽  
Morimitsu Takai ◽  
Kazuo Tomizawa ◽  
Kazuya Tamai

We describe our experience of using a volar locking plate for corrective osteotomy and bone grafting combined with early mobilisation in the treatment of distal radius malunions. Corrective osteotomy of the distal radius was performed through a volar approach, and fixated by a volar locking plate associated with corticocancellous iliac bone grafting in three patients aged 16, 71 and 75 years. Two patients had had volarly displaced malunion and one dorsally displaced malunion. Wrist motin was started immediately after surgery. The average follow-up was 15 months (range, 12–20 months). All osteotomies healed at an average 5.7 weeks post-operatively, resulting in a total arc of wrist motion of 133°, forearm rotation of 167°, and grip strength of 70% of that of the contralateral side. This treatment method proved to be effective and safe.


2016 ◽  
Vol 21 (02) ◽  
pp. 133-139 ◽  
Author(s):  
Tsuyoshi Murase

The conventional corrective osteotomy for malunited distal radius fracture that employs dorsal approach and insertion of a trapezoidal bone graft does not always lead to precise correction or result in a satisfactory surgical outcome. Corrective osteotomy using a volar locking plate has recently become an alternative technique. In addition, the use of patient-matched instrument (PMI) via computed tomography simulation has been developed and is expected to simplify surgical procedures and improve surgical precision. The use of PMI makes it possible to accurately position screw holes prior to the osteotomy and simultaneously perform the correction and place the volar locking plate once the osteotomy is completed. The bone graft does not necessarily require a precise block form, and the problem of the extensor tendon contacting the dorsal plate is avoided. Although PMI placement and soft tissue release technique require some degree of specialized skill, they comprise a very useful surgical procedure. On the other hand, because patients with osteoporosis are at risk of peri-implant fracture, tandem ulnar shortening surgery should be considered to avoid excessive lengthening of the radius.


2020 ◽  
Vol 3 (1) ◽  

Introduction: Distal radius fractures are one of the most common injuries which come to the orthopaedic surgeons. Displaced extra-or intra-articular fractures require anatomical reduction for a good outcome. Historically, these fractures were treated with manipulation and casting, with or without Kirschner (K) wire fixation. Modern plating techniques have been advocated to restore anatomical alignment and allow early mobilisation. Despite the wide variety of treatment options available there is still debate about the best way to treat these fractures. The aim of this study was to evaluate fifty cases of fracture distal end radius treated by open reduction and internal fixation using locking compression plating (LCP). Methods: The present study was carried out on 50 cases of acute fracture distal radius admitted at a tertiary care hospital treated by open reduction and internal fixation using locking compression plating (LCP) between January 2018 and December 2018. Functional results were rated at the end of the study as excellent, good or poor as criteria laid down by Gartland and Werley’s combined subjective and objective criteria. Results: 50 cases of fracture distal radius were selected for study that fulfill the inclusion criteria, were operated and studied. 10 fractures were fixed using Extra-articular Locking Compression T-Plates, 40 fractures were fixed using Juxtaarticular Locking Compression T-Plates. According to the Gartland and Werley’s rating scale, 20 had excellent results, 23 good results, and 07 fair results during latest follow up. Conclusion: Notwithstanding a very small sample size and a short follow up, Volar locking plate osteosynthesis at the distal radius signifies a significant improvement in the treatment of distal radial fractures in terms of restoration of the shape and function of the wrist.


2019 ◽  
Vol 09 (02) ◽  
pp. 136-140
Author(s):  
C. A. Selles ◽  
M. A. M. Mulders ◽  
G. R. Roukema ◽  
C. H. van der Vlies ◽  
B. I. Cleffken ◽  
...  

Abstract Background Closed reduction and cast immobilization of displaced distal radius fractures carries the risk of secondary displacement, which could result in a symptomatic malunion. In patients with a symptomatic malunion, a corrective osteotomy can be performed to improve pain and functional impairment of the wrist joint. Objective The aim of this study was to assess the functional outcomes of children who underwent a corrective osteotomy due to a symptomatic malunion of the distal radius. Methods Between 2009 and 2016, all consecutive corrective osteotomies of the distal radius of patients younger than 18 years were reviewed. The primary outcome was functional outcome assessed with the ABILHAND-Kids score. Secondary outcomes were QuickDASH (Quick Disabilities of Arm, Shoulder, and Hand) score, range of motion, complications, and radiological outcomes. Results A total of 13 patients with a median age of 13 years (interquartile range [IQR]: 12.5–16) were included. The median time to follow-up was 31 months (IQR: 26–51). The median ABILHAND-Kids score was 42 (range: 37–42), and the median QuickDASH was 0 (range: 0–39). Range of motion did not differ significantly between the injured and the uninjured sides for all parameters. One patient had a nonunion requiring additional operative treatment. The postoperative radiological parameters showed an improvement of radial inclination, radial height, ulnar variance, dorsal tilt, and dorsal tilt. Conclusion Corrective osteotomy for children is an effective method for treating symptomatic malunions of the distal radius. Level of Evidence This is a Level IV study.


2011 ◽  
Vol 38 (1) ◽  
pp. 29-34 ◽  
Author(s):  
M. Farshad ◽  
F. Hess ◽  
L. Nagy ◽  
A. Schweizer

Corrective osteotomy for distal radial malunion is a valuable but at times technically challenging operation. We have developed a new device to aid in the performance of the operation. We compared clinical use of the new technique with the standard technique. In 11 patients treated with the new technique the volar locking plate needed repositioning only once. With the standard technique in 17 patients the plate was repositioned in nine cases and needed bending in six cases. The new method corrected radial inclination (SD of 3° vs. 9°) and ulnar variance (SD of 0.9 mm vs. 1.4 mm) more predictably than the standard technique but there was no advantage in correction of volar tilt (SD of 6° vs. 4°). In our experience the new device makes corrective osteotomy of the distal radius easier and more reliable.


2019 ◽  
Vol 24 (01) ◽  
pp. 30-35 ◽  
Author(s):  
Takeshi Katayama ◽  
Hiroshi Ono ◽  
Shohei Omokawa

Background: This study aimed to identify the effect of the progression of postoperative wrist osteoarthritis on 5 years clinical and radiological outcomes after volar locking plate fixation of distal radius fractures. Methods: Altogether, 56 patients with distal radius fractures were followed up 5 years after surgery. Clinical assessment was performed using the Mayo modified wrist score, a visual analogue scale of pain, the Japanese version of the Disabilities of the Arm, Shoulder, and Hand score, and Patient-related wrist evaluation. Standardized wrist radiographs were used to assess wrist morphology and the Knirk and Jupiter’s degree of osteoarthritis. Multivariate logistic regression was used to analyze postoperative morphological changes in the wrist and carpal alignment regarding their correlation with progression of wrist osteoarthritis. Results: Progression of postoperative wrist osteoarthritis was recognized in 37 of the 56 cases (66.1%). Compared with the clinical outcomes at the time of the fracture union completion, almost clinical outcomes improved up to 5 years follow-up time as well as at 1 year after surgery. The range of wrist flexion at 5 years follow-up was significantly less in the progressive osteoarthritis group than in those with non-progressive osteoarthritis. The persistent step-off immediately after surgery significantly affected the postoperative progression of wrist osteoarthritis. Changes in the radial inclination, volar tilt, and radioscaphoid angle correlated with progression of wrist osteoarthritis. The highest correlation was with the change of radioscaphoid angle. Conclusions: Good clinical results were maintained at 5 years after surgery, but progression of postoperative wrist osteoarthritis interfered with improvement of wrist flexion. Change in the radioscaphoid angle was the factor that was most highly correlated with progression of postoperative wrist osteoarthritis.


2021 ◽  
Author(s):  
Xue-yang Gui ◽  
Zhao-hui Cheng ◽  
Hongfei Shi ◽  
Yi-xin Chen ◽  
Jin Xiong ◽  
...  

Abstract Background: Volar locking plating remains a popular method for the surgical management of distal radius fractures. Dorsal metaphyseal comminution (DMC) is a common fracture pattern which weakens the stability during fracture fixation. In this study, we aimed to compare the radiographic and functional outcome of the intra- and extra-articular distal radius fractures with DMC following volar locking plate fixation.Materials and methods: Patients suffered from a distal radius fracture with DMC were reviewed in the clinical database of the authors’ institution between Jan 2016 and Jan 2020. The included patients were classified into the extra-articular (A3) group or the intra-articular (C2 and C3) group according to the AO/OTA system. The radiological parameters, wrist range of motion, and functional outcomes were evaluated following open reduction and volar locking plate fixation.Results: A total of 130 patients were included in this study with a mean follow-up length of 17.2 months. Compared with the A3 fracture group, no significant fracture re-displacement or reduced wrist ROMs was observed in the C2 fractures after 12-month’s follow-up. However, significantly decreased volar tilt (P = 0.003) as well as the extension/flexion ROMs were observed in the C3 fractures comparing to the A3 fractures. Most of the patients achieved an excellent (n = 75) or good (n = 51) Gartland and Werley wrist score. Four patients with C3 fractures resulted in a fair functional outcome due to a significant loss of volar tilt during follow-up.Conclusions: The volar locking plate fixation provided sufficient stability for distal radius fractures with DMC, and resulted in similar radiological and functional outcomes in the intra-articular distal radius fractures with a simple articular component (C2 fractures) as those in the extra-articular fractures. Considering the intra-articular fractures with multifragmentary articular component (C3 fracture), despite of the subsequent loss of volar tilt, the majority of the patients achieved good to excellent wrist function following volar locking plating.Trial registration: Not applicable because the design of the study is retrospective.


Author(s):  
Gaurav Kumar ◽  
Varun Vijay

<p class="abstract"><strong>Background:</strong> The fracture of lower end radius is the most common fracture of upper extremity encountered in practice. Intra-articular fractures of distal radius present a challenging task to the operating surgeon. Open reduction and internal fixation using volar fixed-angle plates has shown to be a valid treatment option for unstable, dorsally displaced distal radial fractures. The present study was undertaken to evaluate the functional outcome of unstable distal radius fractures treated with fixed angle volar locking plate.</p><p class="abstract"><strong>Methods:</strong> The current study aimed at using fixed angle volar locking plate to treat unstable distal radius fractures. A total of 25 patients records were studied comprising of 19 males and 6 females with a mean of 44.5 years and followed up for a maximum of 1.5 year. Fractures were classified using the AO classification. The interpretation of functional outcome was done according to Mayo Wrist Score.<strong></strong></p><p class="abstract"><strong>Results:</strong> At final functional assessment, according to the Mayo wrist score, the scores of 6 patients were excellent, 10 patients good, 8 patients satisfactory and 1 patient poor. No non-union was reported in any patients. 3 patients developed minor complications in the form of superficial infection, hypertrophic scar and reflex sympathetic dystrophy and 1 patient developed major complication in the form of deep infection.</p><p class="abstract"><strong>Conclusions:</strong> Primary volar plate fixation of unstable distal radius fracture provides a stable construct that helps in early mobilization, better functional outcome and minimizes chances of complications and thereby is the treatment of choice for fracture distal end of radius.</p>


2021 ◽  
pp. 1-3
Author(s):  
Kunal Shankar ◽  
Vikash M. Harinandan ◽  
Laljee Chaudhary ◽  
Debarshi Jana

Background: Distal radius fracture is more common accounting for 1/6th of the all fractures. With this background, this study was carried out to compare the functional outcome of volar locking plate and external fixator to the displaced intra-articular distal end radius fractures using Modified Mayo Wrist Score (MMWS). Materials and methods: This study included those patients with distal radius fracture attending the Orthopaedic Department of DMCH, Laheriasarai, Bihar, during January 2019 to December 2019. Patients were randomised based on - even and odd day of the week. This included two set of group with twenty patients in each group- one with volar locking plating and other with external fixation. Patients were followed up at 6 months and 1 year. At each follow up, the pain and range of movements were assessed by MMWS score which was entered in Microsoft excel and analysed in SPSS 20. Results: At the end of one year after surgery, we observed that external fixation technique was superior for treating displaced intra-articular comminuted distal end radius fractures than volar locking plate. Conclusion: External fixator showed more advantageous than volar locking plates after 1year of follow up.


Author(s):  
Shushrut B. Bhavi ◽  
Amith Shanmukgouda Kallanagoudar ◽  
Deepak Kaladagi ◽  
N. B. Sanakal

<p><strong>Background</strong>: Distal radius fractures are one of the most common fractures in an adult population and accounts for 17.5% of all the fractures. The management of distal radius fractures remains debatable despite the availability of different methods of treatment. The aim of this study is to assess the functional outcomes of extra-articular distal radius fractures treated with percutaneous pinning or internal fixation with volar locking plate in adults.</p><p><strong>Methods: </strong>A retrospective study of 40 patients diagnosed with distal radius fracture with AO classification were treated either with percutaneous pinning (n=20) or open reduction and internal fixation with volar locking plate (n=20) were included in study. DASH score and radiographs at 6<sup>th</sup> month was assessed for functional outcome and radiological union.</p><p><strong>Results: </strong>Mean age in plate group was 40 and 45 years in K wire group. The mean passive wrist ROM at the final follow-up evaluation in plate group was 63.8<sup>o</sup> extension and 70.5<sup>o </sup>flexion, 81.7<sup>o</sup> supination and 79<sup>o</sup> pronation, compared with 56.75<sup>o</sup> extension and 65.25<sup>o</sup> flexion, 74.7<sup>o</sup> supination and 85.5<sup>o</sup> pronation in patients treated with K wire group. Patients with plate group and K wire group had DASH score of 19.85 and 18.49 respectively (p=0.07) at 6 months follow-up.</p><p><strong>Conclusions:</strong> The use of ORIF with plate resulted in stable fixation of the unstable extraarticular fractures, allowing early post-surgical wrist motion and has good radiological outcome whereas K wire also has advantages of being minimal invasive, reduced hospital stay and minimal cost.</p>


Sign in / Sign up

Export Citation Format

Share Document