scholarly journals Analysis of the Accuracy and Performance of a Continuous Glucose Monitoring Sensor Prototype: An In-Silico Study Using the UVA/PADOVA Type 1 Diabetes Simulator

2016 ◽  
Vol 11 (3) ◽  
pp. 545-552 ◽  
Author(s):  
Marc D. Breton ◽  
Rolf Hinzmann ◽  
Enrique Campos-Nañez ◽  
Susan Riddle ◽  
Michael Schoemaker ◽  
...  
2017 ◽  
Vol 12 (2) ◽  
pp. 318-324 ◽  
Author(s):  
Kurt Fortwaengler ◽  
Enrique Campos-Náñez ◽  
Christopher G. Parkin ◽  
Marc D. Breton

Objective: An in silico study of type 1 diabetes (T1DM) patients utilized the UVA-PADOVA Type 1 Diabetes Simulator to assess the effect of patient blood glucose monitoring (BGM) system accuracy on clinical outcomes. We applied these findings to assess the financial impact of BGM system inaccuracy. Methods: The study included 43 BGM systems previously assessed for accuracy according to ISO 15197:2003 and ISO 15197:2013 criteria. Glycemic responses for the 100 in silico adult T1DM subjects were generated, using each meter. Changes in estimated HbA1c, severe hypoglycemic events, and health care resource utilization were computed for each simulation. The HbA1c Translator modeling approach was used to calculate the financial impact of these changes. Results: The average cost of inaccuracy associated with the entire group of BGM systems was £155 per patient year (PPY). The average additional cost of BGM systems not meeting the ISO 15197:2003 standard was an estimated £178 PPY more than an average system that fulfills the standard and an estimated £235 PPY more than an average system that appears to meet the ISO 15197:2013 standard. Conclusion: There is a clear relationship between BGM system accuracy and cost, with the highest costs being associated with BGM systems not meeting the ISO 15197:2003 standard. Lower costs are associated with systems meeting the ISO 15197:2013 system accuracy criteria. Using BGM systems that meet the system accuracy criteria of the ISO 15197:2013 standard can help reduce the clinical and financial consequences associated with inaccuracy of BGM devices.


2021 ◽  
pp. 193229682110431
Author(s):  
Giulia Noaro ◽  
Giacomo Cappon ◽  
Giovanni Sparacino ◽  
Federico Boscari ◽  
Daniela Bruttomesso ◽  
...  

Background: Providing real-time magnitude and direction of glucose rate-of-change (ROC) via trend arrows represents one of the major strengths of continuous glucose monitoring (CGM) sensors in managing type 1 diabetes (T1D). Several literature methods were proposed to adjust the standard formula (SF) used for insulin bolus calculation by accounting for glucose ROC, but each of them provides different suggestions, making it difficult to understand which should be applied in practice. This work aims at performing an extensive in-silico assessment of their performance and safety. Methods: The methods of Buckingham (BU), Scheiner (SC), Pettus/Edelman (PE), Klonoff/Kerr (KL), Aleppo/Laffel (AL), Ziegler (ZI), and Bruttomesso (BR) were evaluated using the UVa/Padova T1D simulator, in single-meal scenarios, where ROC and glucose at mealtime varied between [-2,+2] mg/dL/min and [80,200] mg/dL, respectively. Efficacy of postprandial glucose control was quantitatively assessed by time in, above and below range (TIR, TAR, and TBR, respectively). Results: For negative ROCs, all methods proved to increase TIR and decrease TAR and TBR vs SF, with KL, PE, and BR being the most effective. For positive ROCs, a general worsening of the performances is present, only BR improved the glycemic control when mealtime glucose was close to hypoglycemia, while SC resulted the safest in the other conditions. Conclusions: Insulin bolus adjustment methods are effective for negative ROCs, but they generally appear to overdose for positive ROCs, calling for safer strategies in such a scenario. These results can be useful in outlining guidelines to identify which adjustment to apply based on the mealtime condition.


Author(s):  
Peris Begoña Pla ◽  
Leví Ana M Ramos ◽  
Vargas Marcos Lahera ◽  
Casieri Raffaele Carraro ◽  
Moreno Nerea Aguirre ◽  
...  

Author(s):  
Ruxandra Calapod Ioana ◽  
Irina Bojoga ◽  
Duta Simona Gabriela ◽  
Ana-Maria Stancu ◽  
Amalia Arhire ◽  
...  

Diabetes ◽  
2018 ◽  
Vol 67 (Supplement 1) ◽  
pp. 1179-P ◽  
Author(s):  
THOMAS DANNE ◽  
BERTRAND CARIOU ◽  
JOHN B. BUSE ◽  
SATISH K. GARG ◽  
JULIO ROSENSTOCK ◽  
...  

Diabetes ◽  
2018 ◽  
Vol 67 (Supplement 1) ◽  
pp. 932-P
Author(s):  
LUDI FAN ◽  
COLLEEN GAREY ◽  
JINGWEN LIU ◽  
BETH MITCHELL ◽  
JEOFFREY BISPHAM ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document