Broad beam attenuation of kilovoltage photon beams: effect of ion chambers.

1998 ◽  
Vol 71 (841) ◽  
pp. 68-73 ◽  
Author(s):  
I J Das
2009 ◽  
Vol 37 (1) ◽  
pp. 96-107 ◽  
Author(s):  
Frédéric Tessier ◽  
Iwan Kawrakow
Keyword(s):  

1987 ◽  
Vol 14 (1) ◽  
pp. 135-139 ◽  
Author(s):  
Ellen E. El-Khatib ◽  
Ervin B. Podgorsak ◽  
Conrado Pla

2008 ◽  
Vol 18 (3) ◽  
pp. 197-202 ◽  
Author(s):  
Syed F. Akber ◽  
Indra J. Das ◽  
Than S. Kehwar
Keyword(s):  
X Ray ◽  

Radiology ◽  
1955 ◽  
Vol 64 (1) ◽  
pp. 114-114
Author(s):  
E. Dale Trout ◽  
John P. Kelley ◽  
Arthur C. Lucas ◽  
Edward J. Furno
Keyword(s):  
X Ray ◽  

Radiology ◽  
1972 ◽  
Vol 104 (1) ◽  
pp. 171-175 ◽  
Author(s):  
John P. Kelley ◽  
E. Dale Trout
Keyword(s):  
X Rays ◽  

2018 ◽  
Vol 17 (4) ◽  
pp. 377-383
Author(s):  
Hamza Wajid ◽  
Andre Fleck ◽  
Johnson Darko ◽  
Ernest Osei

AbstractAimThe purpose of the study was to investigate the detailed angularly dependent attenuation characteristics of three different commercial couch-tops: Varian IGRT, Qfix kVue Standard and Qfix kVue Dose Max couch-tops used in radiation therapy.Materials and methodsThe attenuation of photon beams by the treatment couch-tops was measured using a farmer chamber inserted at the centre of a 16 cm diameter cylindrical acrylic phantom for five different photon energies: 6 MV, 6FFF MV, 10 MV, 10FFF MV and 15 MV photon beams. The Varian IGRT couch-top has three different thicknesses thus attenuation measurements were done at the three different longitudinal locations. Measurements were made with the sliding support rails of the Qfix kVue Standard and Qfix kVue Dose Max couch-tops at both ‘rails-in’ and ‘rails-out’ positions. All measurements were taken for several projections through 360° movement of the gantry and for two different field sizes; 5×5 cm2 and 10×10 cm2.Results and findingsThe results indicate that the maximum attenuation of the Varian IGRT couch-top at the thin, medium and thick portions are 5·1, 5·7 and 8·9%, respectively, the Qfix kVue Standard couch with the rails-in and rails-out are 11·2 and 13·7%, respectively, and Qfix kVue Dose Max couch-top with rails-in and rails-out are 9·7 and 13·8%, respectively. The results from this study can be used to account for the couch-top attenuation during radiation treatment planning of patients treated with these couch-tops.


1996 ◽  
Vol 41 (6) ◽  
pp. 1025-1035 ◽  
Author(s):  
A Piermattei ◽  
L Azario ◽  
G Arcovito ◽  
M P Toni

Sign in / Sign up

Export Citation Format

Share Document