Bone-conduction tests were administered to subjects who feigned a hearing loss in the right ear. The tests were conducted under two conditions: With and without occlusion of the non-test ear. It was anticipated that the occlusion effect, a well-known audiological principle, would operate to draw low frequency bone-conducted signals to the occluded side in a predictable manner. Results supported this expectation and are discussed in terms of their clinical implications.