Bone conduction devices, solutions for patients with severe mixed hearing loss.

Author(s):  
Pla-Gil Ignacio
2021 ◽  
Vol 75 (4) ◽  
pp. 1-5
Author(s):  
Joanna Marszał ◽  
Renata Gibasiewicz ◽  
Magdalena Błaszczyk ◽  
Maria Gawlowska ◽  
Wojciech Gawęcki

Introduction: Nowadays, there are many options to treat hearing-impaired patients: tympanoplastic surgery, hearing aids and a wide range of implantable devices. Objective: The aim of this study is to present the mid-term audiological and quality of life benefits after the implantation of the Osia®, a new active piezoelectric bone conduction hearing implant. Material and methods: The state of the tissues in implanted area, as well as audiological and quality of life results were analyzed six, nine and twelve months after implantation in a group of four adult patients with bilateral mixed hearing loss. Results: In all the cases, no postoperative complications were found. One year after surgery the mean audiological gain in FF PTA4 (pure tone average for 0.5, 1, 2, and 4 kHz) was 52.2±3.5 dB in comparison to the unaided situation, the mean speech understanding with Osia® in quiet was 90±8.2% for 50dB SPL, 98.8±2.5% for 65dB SPL and 100±0% for 80dB SPL, and mean speech understanding with Osia® in noise was 37.5%±23.6 for 50dB SPL, 93.8±4.8% for 65dB SPL and 98.8±2.5% for 80dB SPL. There was also an evident improvement in the quality of hearing as well as in the quality of life, measured by the APHAB (Abbreviated Profile of Hearing Aid Benefit) and the SSQ (Speech, Spatial and Qualities of Hearing Scale). Conclusions: The Osia® is an effective treatment option for patients with bilateral mixed hearing loss. The mid-term audiological and quality of life results are excellent, but further observations including bigger groups of patients and a longer follow-up are required.


1975 ◽  
Vol 84 (1) ◽  
pp. 11-15 ◽  
Author(s):  
Fred H. Linthicum ◽  
A. S. Lalani

Audiometric findings were evaluated in a group of patients with clinical unilateral otosclerosis. A comparison was made between bone conduction threshold in the better hearing ear and the ear with the mixed hearing loss. Over 50% of the patients had a significant elevation in the bone conduction thresholds in the ear with clinical otosclerosis as compared to the uninvolved ear. A pair of temporal bones from a patient with unilateral otosclerosis and unilateral mixed hearing loss is presented.


2019 ◽  
Vol 277 (3) ◽  
pp. 715-725
Author(s):  
Pierre Dolhen ◽  
Samuel Lipski ◽  
Rachid Touijar ◽  
Juliette Van Bogaert

Abstract Introduction The BAHA (bone-anchored hearing aid) Attract is a magnetic transcutaneous bone conduction device anchored into the temporal bone. The standard surgical technique for BAHA Attract is a multi-tools time-consuming process, which requires a large cutaneous incision. The objective of this study is to describe and test the feasibility of a minimally invasive pocket (MIP) technique for Magnet Bone Implant Hearing Aid (MBIHA) with a modified magnet of BAHA Attract without fixation and without any tissue reduction. We use a 3-cm vertical skin incision and a subperiosteal pocket. Method A study of 10 patients with conductive or mixed hearing loss who benefited from a MBIHA using the MIP technique is presented. The pure tone average (PTA) (dB) for air-conduction thresholds and the speech recognition threshold (SRT) (dB) in speech audiometry in quiet are calculated. The Entific Medical Systems (EMS) questionnaire and the postoperative clinical outcomes are realized. Results We found a significant improvement of 33.8 dB on average for the PTA and 44.8 dB for the SRT with MBIHA at 3 months, compared with unaided situation. No implant was removed or displaced after 2 years of follow-up. The skin condition remains intact in all the cases. Conclusion The minimally subperiosteal pocket surgical technique MIP without fixation and with tissue preservation for the MBIHA is safe, rapid and effective for patients with conductive or mixed hearing loss. It opens new perspectives of development and modify conventional concept in magnetic coupling of bone-conducted device.


2013 ◽  
Vol 34 (4) ◽  
pp. 598-603 ◽  
Author(s):  
Jolien B. J. Desmet ◽  
Arjan J. Bosman ◽  
Ad F. M. Snik ◽  
Peggy Lambrechts ◽  
Myrthe K. S. Hol ◽  
...  

2021 ◽  
Vol 10 (24) ◽  
pp. 5916
Author(s):  
Katarzyna B. Cywka ◽  
Henryk Skarżyński ◽  
Bartłomiej Król ◽  
Piotr H. Skarżyński

Background: the Bonebridge hearing implant is an active transcutaneous bone conduction implant suitable for various types of hearing loss. It was first launched in 2012 as the BCI 601, with a newer internal part (BCI 602) released in 2019. With the new size and shape, the BCI 602 can be used in patients previously excluded due to insufficient anatomical conditions, especially in patients with congenital defects of the outer and middle ear. Objectives: the purpose of this study is to evaluate the objective and subjective benefits of the new Bonebridge BCI 602 in children who have hearing impairment due to conductive or mixed hearing loss. Safety and effectiveness of the device was assessed. Methods: the study group included 22 children aged 8–18 years (mean age 14.7 years) who had either conductive or mixed hearing loss. All patients were implanted unilaterally with the new Bonebridge BCI 602 implant. Pure tone audiometry, speech recognition tests (in quiet and noise), and free-field audiometry were performed before and after implantation. Word recognition scores were evaluated using the Demenko and Pruszewicz Polish Monosyllabic Word Test, and speech reception thresholds in noise were assessed using the Polish Sentence Matrix Test. The subjective assessment of benefits was carried outusing the APHAB (Abbreviated Profile of Hearing Aid Benefit) questionnaire. Results: after implantation of the Bonebridge BCI 602 all patients showed a statistically significant improvement in hearing and speech understanding. The mean word recognition score (WRS) changed from 12.1% before implantation to 87.3% after 6 months. Mean speech reception threshold (SRT) before implantation was +4.79 dB SNR and improved to −1.29 dB SNR after 6 months. All patients showed stable postoperative results. The APHAB questionnaire showed that difficulties in hearing decreased after implantation, with a statistically significant improvement in global score. Pre-operative scores (M = 35.7) were significantly worse than post-operative scores at 6 months (M = 25.7). Conclusions: the present study confirms that the Bonebridge BCI 602 is an innovative and effective solution, especially for patients with conductive and mixed hearing loss due to anatomical ear defects. The Bonebridge BCI 602 system provides valuable and stable audiological and surgical benefits. Subjective assessment also confirms the effectiveness of the BCI 602. The BCI 602 offers the same amplification as the BCI601, but with a smaller size. The smaller dimensions make it an effective treatment option for a wider group of patients, especially children with congenital defects of the outer and middle ear.


2015 ◽  
Vol 20 (01) ◽  
pp. 034-038 ◽  
Author(s):  
Maria Mondelli ◽  
Thais Mariano ◽  
Heitor Honório ◽  
Rubens Brito

Introduction Hearing loss is the most common clinical finding in patients with malformation of the external ear canal. Among the possibilities of treatment, there is the adaptation of hearing aids by bone conduction and the adaptation of implantable hearing aids. Objective To assess speech perception with the use of Vibrant Soundbridge (VBS - MED-EL, Innsbruck, Austria) associated with additional amplification in patients with bilateral craniofacial malformation. Method We evaluated 11 patients with bilateral malformation over 12 years with mixed hearing loss or bilateral conductive. They were using the Softband (Oticon Medical, Sweden) and bone conduction hearing aid in the ear opposite the one with the VSB. We performed the evaluation of speech perception using the Hearing in Noise Test. Results Participants were eight men and three women with a mean of 19.5 years. The signal / noise ratio presented significant results in patients fitted with VSB and bone conduction hearing aid. Conclusion The results of speech perception were significantly better with use of VBS combined with bone conduction hearing aids.


2015 ◽  
Vol 18 (7) ◽  
pp. A364
Author(s):  
M Kosaner Kliess ◽  
R Zoehrer ◽  
B Schlick ◽  
M Mariacher ◽  
M Urban

2018 ◽  
Vol 23 (2) ◽  
pp. 82-88 ◽  
Author(s):  
Caroline Salmon ◽  
Sébastien Barriat ◽  
Philippe P. Lefebvre

Objectives: To evaluate the efficacy of stapes surgery in patients presenting with a preoperative mixed hearing loss (bone conduction thresholds ≥40 dB; 40 < air conduction thresholds (AC) < 85 dB). Patients and Methods: A total of 30 patients (32 ears) with mixed hearing loss who underwent primary stapedotomy were evaluated. Audiometric parameters were assessed before and after surgery. Contralateral thresholds were also reported. The need for a hearing aid (HA) after surgery and its impact on quality of life were also measured. Results: AC and word recognition at 40, 55 and 70 dB were significantly improved after stapes surgery. Only 16.6% of the patients needed an HA after surgery and reported being satisfied with the aid. Conclusion: Stapes surgery improved auditory function in patients with mixed hearing loss, allowing most patients to delay the need for an HA without worsening their quality of life.


Sign in / Sign up

Export Citation Format

Share Document