The Use of Negative Pressure Wound Therapy in Patients with Open Fractures

OrthoMedia ◽  
2022 ◽  
2020 ◽  
Vol 102-B (7) ◽  
pp. 912-917 ◽  
Author(s):  
Muhammad Tahir ◽  
Ejaz A. Chaudhry ◽  
Faridullah K. Zimri ◽  
Nadeem Ahmed ◽  
Saeed A. Shaikh ◽  
...  

Aims It has been generally accepted that open fractures require early skeletal stabilization and soft-tissue reconstruction. Traditionally, a standard gauze dressing was applied to open wounds. There has been a recent shift in this paradigm towards negative pressure wound therapy (NPWT). The aim of this study was to compare the clinical outcomes in patients with open tibial fractures receiving standard dressing versus NPWT. Methods This multicentre randomized controlled trial was approved by the ethical review board of a public sector tertiary care institute. Wounds were graded using Gustilo-Anderson (GA) classification, and patients with GA-II to III-C were included in the study. To be eligible, the patient had to present within 72 hours of the injury. The primary outcome of the study was patient-reported Disability Rating Index (DRI) at 12 months. Secondary outcomes included quality of life assessment using 12-Item Short-Form Health Survey questionnaire (SF-12), wound infection rates at six weeks and nonunion rates at 12 months. Logistic regression analysis and independent-samples t-test were applied for secondary outcomes. Analyses of primary and secondary outcomes were performed using SPSS v. 22.0.1 and p-values of < 0.05 were considered significant. Results A total of 486 patients were randomized between January 2016 and December 2018. Overall 206 (49.04%) patients underwent NPWT, while 214 (50.95%) patients were allocated to the standard dressing group. There was no statistically significant difference in DRI at 12 months between NPWT and standard dressing groups (mean difference 0.5; 95% confidence interval (CI) -0.08 to 1.1; p = 0.581). Regarding SF-12 scores at 12 months follow-up, there was no significant difference at any point from injury until 12 months (mean difference 1.4; 95% CI 0.7 to 1.9; p = 0.781). The 30-day deep infection rate was slightly higher in the standard gauze dressing group. The non-union odds were also comparable (odds ratio (OR) 0.90, 95% CI 0.56 to 1.45; p = 0.685). Conclusion Our study concludes that NPWT therapy does not confer benefit over standard dressing technique for open fractures. The DRI, SF-12 scores, wound infection, and nonunion rates were analogous in both study groups. We suggest surgeons continue to use cheaper and more readily available standard dressings. Cite this article: Bone Joint J 2020;102-B(7):912–917.


2020 ◽  
Vol 34 (5) ◽  
pp. 223-230 ◽  
Author(s):  
Marc C. Grant-Freemantle ◽  
Éanna J. Ryan ◽  
Sean O. Flynn ◽  
Darren P. Moloney ◽  
Michael A. Kelly ◽  
...  

2014 ◽  
Vol 22 (1) ◽  
pp. 30-34 ◽  
Author(s):  
Takashi Suzuki ◽  
Akihiro Minehara ◽  
Terumasa Matsuura ◽  
Tadashi Kawamura ◽  
Kazui Soma

2013 ◽  
Vol 54 (11) ◽  
Author(s):  
J Joethy ◽  
SJ Sebastin ◽  
KS Chong ◽  
YP Peng ◽  
ME Puhaindran

2014 ◽  
Vol 47 (03) ◽  
pp. 412-417
Author(s):  
Surath Amarnath ◽  
Mettu Rami Reddy ◽  
Chayam Hanumantha Rao ◽  
Harsha Vardan Surath

ABSTRACT Background: Negative pressure wound therapy (NPWT) is an established modality in the treatment of chronic wounds, open fractures, and post-operative wound problems. This method has not been widely used due to the high cost of equipment and consumables. This study demonstrates an indigenously developed apparatus which gives comparable results at a fraction of the cost. Readily available materials are used for the air-tight dressing. Materials and Methods: Equipment consists of suction apparatus with adjustable pressure valve set to a pressure 125-150 mmHg. An electronic timer switch with a sequential working time of 5 min and a standby time of 3 min provides the required intermittent negative pressure. Readily available materials such as polyvinyl alcohol sponge, suction drains and steridrapes were used to provide an air tight wound cover. Results: A total of 90 cases underwent 262 NPWT applications from 2009 to 2014. This series, comprised of 30 open fractures, 21 post-operative and 39 chronic wounds. The wound healing rate in our study was comparable to other published studies using NPWT. Conclusion: The addition of electronic timer switch will convert a suction apparatus into NPWT machine, and the results are equally effective compared to more expensive counter parts. The use of indigenous dressing materials reduces the cost significantly.


Sign in / Sign up

Export Citation Format

Share Document