Bronchopleural Fistula Closure With Amplatzer Device

CHEST Journal ◽  
2013 ◽  
Vol 144 (4) ◽  
pp. 27A
Author(s):  
Amit Goyal ◽  
Sara Greenhill ◽  
Kevin Kovitz ◽  
Neeraj Desai
2020 ◽  
Vol 27 (3) ◽  
pp. e41-e45
Author(s):  
Elliot Ho ◽  
Rohit Srivastava ◽  
Pravachan Hegde

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jisong Zhang ◽  
Huihui Hu ◽  
Li Xu ◽  
Shan Xu ◽  
Jihong Zhu ◽  
...  

Abstract Background Bronchopleural fistula (BPF) is a relatively rare complication after various types of pulmonary resection. The double-sided mushroom-shaped occluder (Amplatzer device, AD) has been gradually used for BPF blocking due to its reliable blocking effect. We have improved the existing AD implantation methods to facilitate clinical use and named the new approach Sheath-free method (SFM). The aim of the present report was to explore the reliability and advantages of the SFM in AD implantation. Methods We improved the existing implantation methods by abandoning the sheath of the AD and using the working channel of the bronchoscope to directly store or release the AD without general anesthesia, rigid bronchoscopy, fluoroscopy, or bronchography. A total of 6 patients (5 men and 1 woman, aged 66.67 ± 6.19 years [mean ± SD]) had BPF blocking and underwent the SFM in AD implantation. Results AD implantation was successfully performed in all 6 patients with the SFM, 4 persons had a successful closure of the fistula, one person died after few days and one person did not have a successful closure of the fistula. The average duration of operation was 16.17 min (16.17 ± 4.67 min [mean ± SD]). No patients died due to operation complications or BPF recurrence. The average follow-up time was 13.2 months (range 10–17 months). Conclusion We observed that the SFM for AD implantation—with accurate device positioning and a clear field of vision—is efficient and convenient. The AD is effective in BPF blocking, and could contribute to significantly improved symptoms of patients.


2009 ◽  
Vol 137 (1) ◽  
pp. e46-e47 ◽  
Author(s):  
Cemal Asim Kutlu ◽  
Suat Patlakoglu ◽  
Ahmet Erdal Tasci ◽  
Oguz Kapicibasi

Author(s):  
Igor Ya Motus ◽  
Alexander V Bazhenov ◽  
Rauf T Basyrov ◽  
Anna S Tsvirenko

Abstract OBJECTIVES A bronchopleural fistula after pneumonectomy is a relatively rare but very serious complication. The development of endoscopic methods of treatment opens a new page in treating this condition. The goal of this paper was to confirm that the atrial septal defect Amplatzer device can be used for bronchopleural fistula closure in properly selected patients. METHODS A retrospective study of 13 patients with bronchopleural fistula after pneumonectomy was performed. There were 11 men and 2 women aged 26–70 years. Right-sided fistulas occurred in 10 patients and left-sided fistulas occurred in 3. The underlying disease was lung cancer in 7 patients and pulmonary tuberculosis in 6. Video-assisted thoracoscopic surgery (N = 7) and open-window thoracostomy (N = 6) were used to treat the empyema. To treat occlusion of the bronchial fistulas, we used Amplatzer atrial septal defect occluders originally intended for closure of ventricular and interatrial septal defects. The occluder was inserted from the bronchus by flexible bronchoscopy with the patient under local anaesthesia, with the help of video-assisted thoracoscopy or through a window thoracostomy from the pleural cavity. RESULTS We noted 3 complications after the procedure. In 2 patients, displacement of the occluders required re-installation in 1 patient and latissimus dorsi muscle coverage in the other. In the third patient, the occluder became dislodged during severe exacerbation of tuberculosis that occurred after the patient violated the treatment regimen. She died of tuberculosis 6 months after the occluder was inserted. The course in the remaining 10 patients was uneventful. CONCLUSIONS Our experience suggests that the use of an atrial septal defect occluder for the treatment of a bronchial fistula after pneumonectomy is a reliable option.


Thorax ◽  
2017 ◽  
Vol 72 (7) ◽  
pp. 668-670 ◽  
Author(s):  
Antolina Gómez López ◽  
Ricardo García Luján ◽  
Alicia De Pablo Gafas ◽  
Felipe Hernández Hernández ◽  
Victoria Villena Garrido ◽  
...  

2021 ◽  
Vol 19 (1) ◽  
Author(s):  
Yongyong Wu ◽  
Zhongliang He ◽  
Weihua Xu ◽  
Guoxing Chen ◽  
Zhijun Liu ◽  
...  

Abstract Background Bronchopleural fistula (BPF) refers to an abnormal channel between the pleural space and the bronchial tree. It is a potentially fatal postoperative complication after pulmonary resection and a complex challenge for thoracic surgeons because many patients with BPF ultimately develop refractory empyema, which is difficult to manage and has a major impact on quality of life and survival. Therefore, an operative intervention combined with conservative and endoscopic therapies may be required to control infection completely, to occlude BPF, and to obliterate the empyema cavity during treatment periods. Case presentation Two patients who suffered from BPF complicated with chronic empyema after lobectomy were treated in other hospitals for a long time and did not recover. In our department, we performed staged surgery and creatively combined an Amplatzer Septal Occluder (ASO) device (AGA Medical Corp, Golden Valley, MN, USA) with pedicled muscle flap transposition. First, open-window thoracostomy (OWT), or effective drainage, was performed according to the degree of contamination in the empyema cavity after the local infection was controlled. Second, Amplatzer device implantation and pedicled muscle flap transposition was performed at the same time, which achieved the purpose of obliterating the infection, closing the fistula, and tamponading the residual cavity. The patients recovered without complications and were discharged with short hospitalization stays. Conclusions We believe that the union of the Amplatzer device and pedicle muscle flap transposition seems to be a safe and effective treatment for BPF with chronic empyema and can shorten the length of the related hospital stay.


2020 ◽  
Vol 9 (1) ◽  
pp. 106
Author(s):  
Neeraj Sharma ◽  
Vasu Vardhan ◽  
ChandanSingh Katoch ◽  
Aseem Yadav

2020 ◽  
Author(s):  
Jisong Zhang ◽  
Huihui Hu ◽  
Li Xu ◽  
Shan Xu ◽  
Jihong Zhu ◽  
...  

Abstract Background: Bronchopleural fistula (BPF) is a relatively rare complication after various types of pulmonary resection. The double-sided mushroom-shaped occluder (Amplatzer device, AD) has been gradually used for BPF blocking due to its reliable blocking effect. We have improved the existing AD implantation methods to facilitate clinical use and named the new approach the Sheath-free method (SFM the aim of the present report was to explore the reliability and advantages of SFM for AD implantation.Methods: We improved the existing placement methods by abandoning the sheath of the AD and using the working channel of the bronchoscope to directly store or release the AD without the use of general anesthesia, rigid bronchoscopy, fluoroscopy, or bronchography. A total of 6 patients (5 men and 1 woman, aged 66.67±6.19 years [mean ± SD]) had bronchopleural fistulas sealed using the SFM for AD implantation. Results: Closure was successfully performed in all 6 patients with the SFM, and the average duration of operation was 16.17 minutes (16.17±4.67 minutes [mean ± SD]). Five patients achieved complete occlusion after the operation, and 1 patient who had multiple fistulas did not. No patients died due to operation complications and BPF recurrence. The average follow-up time was 13.2 months (range: 10-17 months).Conclusion: We observed that the SFM for AD implantation—with accurate device positioning and a clear field of vision—is efficient and convenient. The AD is effective in BPF sealing, and patient symptoms significantly improved after sealing.


2019 ◽  
Vol 27 (6) ◽  
pp. 505-508
Author(s):  
Alexander Victorovich Bashenow ◽  
Igor Yakovlevich Motus ◽  
Anna Sergeevna Tsvirenko ◽  
Igor Davydovich Medvinskiy ◽  
Sergey Alexandrovich Dovbnya ◽  
...  

We present a case of successful closure of a para-occluder fistula. The bronchopleural fistula occurred after a right-sided pneumonectomy performed for multidrug-resistant tuberculosis. Initial closure of the bronchopleural fistula with the use of an atrial septal defect occluder 3 years later led to relapse of the fistula after 2 years. To manage the relapsing bronchopleural fistula, we partially destroyed the former nonfunctioning occluder, measured the size of the bronchial defect with a sizing balloon, and installed an atrial septal defect occluder of a larger size.


Sign in / Sign up

Export Citation Format

Share Document