scholarly journals An Economic Evaluation of Continuous Glucose Monitoring for People with Type 1 Diabetes and Impaired Awareness of Hypoglycaemia within North West London Clinical Commissioning Groups in England

2017 ◽  
Vol 13 (02) ◽  
pp. 81 ◽  
Author(s):  
Shraddha Chaugule ◽  
Nick Oliver ◽  
Brigitte Klinkenbijl ◽  
Claudia Graham ◽  
◽  
...  

Objective: To assess the economic impact of providing real time continuous glucose monitoring (CGM) for people with type 1 diabetes (T1D) and impaired awareness of hypoglycaemia (IAH) within North West (NW) London clinical commissioning groups (CCGs). Methods: The eligible population for CGM and inputs for the economic budget impact model developed were derived from published data. The model includes cost of CGM; cost savings associated with lower hypoglycaemia related hospital admissions, accidents and emergency visits; self-monitoring of blood glucose (SMBG) strip usage; and glycated haemoglobin (HbA1c) reduction-related avoided complications and insulin pump use. Results: The cost of CGM for T1D-IAH (n=3,036) in the first year is £10,770,671 and in the fourth year is £11,329,095. The combined cost off-sets related to reduced hypoglycaemia admissions, SMBG strip usage and complications are £8,116,912 and £8,741,026 in years one and four, respectively. The net budget impact within the NW London CCGs is £2,653,760; £2,588,068 in years one and four respectively. Conclusions: Introduction of CGM for T1D-IAH patients will have a minimal budget impact on NW London CCGs, driven by cost of CGM and offsets from lower hypoglycaemia-related costs, reduced SMBG strip usage, avoided HbA1c-related complications and lower insulin pump use.

2017 ◽  
Vol 19 (10) ◽  
pp. 595-599 ◽  
Author(s):  
Cornelis A.J. van Beers ◽  
Maartje de Wit ◽  
Susanne J. Kleijer ◽  
Petronella H. Geelhoed-Duijvestijn ◽  
J. Hans DeVries ◽  
...  

2018 ◽  
Vol 20 (10) ◽  
pp. 2458-2466 ◽  
Author(s):  
Revital Nimri ◽  
Eyal Dassau ◽  
Tomer Segall ◽  
Ido Muller ◽  
Natasa Bratina ◽  
...  

2012 ◽  
Vol 166 (4) ◽  
pp. 567-574 ◽  
Author(s):  
A Szypowska ◽  
A Ramotowska ◽  
K Dżygało ◽  
D Golicki

ObjectiveReal-time continuous glucose monitoring (RT-CGM) provides detailed information on glucose patterns and trends, thus allowing the patients to manage their diabetes more effectively.DesignThe aim of this study was to explore the potential beneficial effects of the use of RT-CGM on diabetes management compared with self blood glucose measurement (SBGM) in patients with type 1 diabetes mellitus (T1DM), by means of a systematic review and meta-analysis of randomized controlled trials (RCTs).MethodsMEDLINE, EMBASE, and the Cochrane Library were searched through by two independent investigators for RCTs concerning the use of RT-CGM in patients with T1DM. Only studies with a similar insulin regimen in the experimental and control groups were included in the analysis.ResultsSeven RCTs (n=948) met the inclusion criteria. Combined data from all studies showed better HbA1c reduction in subjects using RT-CGM compared with those using SBGM (mean difference (MD) −0.25; 95% confidence interval (95% CI): from −0.34 to −0.17; P<0.001). Patients treated with insulin pump and RT-CGM had a lower HbA1c level compared with subjects managed with insulin pump and SBGM (four RCTs, n=497; MD −0.26; 95% CI: from −0.43 to −0.10; P=0.002). The benefits of applying RT-CGM were not associated with an increasing rate of major hypoglycemic episodes. The use of RT-CGM for over 60–70% of time was associated with a significant lowering of HbA1c.ConclusionsRT-CGM is more beneficial than SBGM in reducing HbA1c in patients with type 1 diabetes. Further studies are needed to evaluate the efficacy of this system in the pediatric population, especially in very young children.