scholarly journals Longitudinal Stent Deformation in Undeployed Stents: A Case Series

Author(s):  
Parminder Singh Otaal ◽  
Dinakar Bootla

Longitudinal stent deformation (LSD) is a recently reported problem with newer generation stents. The modification of stent materials and designs to make them more deliverable and conformable, as well as a focused approach in retaining their radial strength, has compromised longitudinal strength in currently available stents. Additionally, enhanced stent radiopacity, improved fluoroscopy, and heightened awareness have led to an increased incidence rate of the potentially under-recognized problem of LSD. Although originally described in deployed stents, LSD is being recognized in undeployed stents too. With available data to suggest an increased rate of adverse cardiac events like stent thrombosis and in-stent restenosis with LSD in deployed stents, an attempt to retrieve an undeployed deformed stent appears justified. We report 3 cases of LSD in undeployed stents and discuss its recognition. We also discuss the retrieval and visual inspection of retrieved stents and the simultaneous completion of coronary interventions via a double guide technique.

2002 ◽  
Vol 39 ◽  
pp. 51
Author(s):  
Philip Urban ◽  
Patrick Serruys ◽  
Dietrich Baumgart ◽  
Antonio Colombo ◽  
Sigmund Silber ◽  
...  

2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Daoyuan Si ◽  
Yaliang Tong ◽  
Bo Yu ◽  
Yuquan He ◽  
Guohui Liu

Circulation ◽  
2007 ◽  
Vol 116 (suppl_16) ◽  
Author(s):  
Hisashi Umeda ◽  
Tomoko Gochi ◽  
Mitsunori Iwase ◽  
Ryoji Ishiki ◽  
Hideo Izawa ◽  
...  

Background: Recently, stent fracture (SF) of sirolimus-eluting stents (SES) has been shown to be associated with an increased risk of restenosis after SES implantation. We sought to assess the incidence, predictors, and clinical outcome of SF after implantation of SES. Methods: A consecutive series of 430 lesions of 382 patients treated with SES followed by coronary angiography at 6 to 9 months were analyzed. SF was defined as complete transverse liner separation or single or multiple stent strut fracture. Results: At follow up, SF occurred in 33 of 430 lesions (7.7%), and 32 of 382 patients (8.4%). In 23 of 33 lesions (69.7%), SF was found in a single point, whereas SF occurred in 2 or more points per lesion in 10 lesions (30.3%). Minimal lumen diameter was significantly smaller in patients with SF (2.11±0.64 mm vs. 2.52±0.60 mm, P <0.001), presumably due to greater late lumen loss (0.36±0.57 mm vs. 0.08±0.50 mm, P =0.005). Consequently, in-stent restenosis in lesions with SF was observed more frequently than non-SF lesions (15.2% vs. 4.0%, P =0.004). At 450 days, however, the cumulative rate of major adverse cardiac events (death, myocardial infarction, or target lesion revascularization) was similar in patients with and without SF (9.1% vs. 7.1%, P =0.722). Multivariable predictors of SF were shown in Figure . Conclusions: The occurrence of SF 6 to 9 months after implantation of SES in consecutive “real-world” patients was relatively common, which did not lead to an increased risk of adverse cardiac events at 450 days. Total stent length, the reduction in the lesion angle by stenting, and lesions located on the right coronary artery were identified as predictors of SF after implantation of SES.


Cardiology ◽  
2010 ◽  
Vol 116 (3) ◽  
pp. 190-193 ◽  
Author(s):  
Michael A. Ferguson ◽  
Matthew Needleman ◽  
Eric S. Mitchell ◽  
Luther I. Carter ◽  
Alexander I. Bustamante ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document