DEVELOPMENT AND VALIDATION OF STABILITY INDICATING RP-HPLC METHOD FOR THE ESTIMATION OF APREMILAST BY FORCED DEGRADATION STUDIES

Author(s):  
N. A. Lonkar
2017 ◽  
Vol 9 (5) ◽  
pp. 121 ◽  
Author(s):  
Hemant K. Jain ◽  
Archana A. Gunjal

Objective: To develop an accurate, simple, precise and specific stability indicating RP-HPLC method for estimation of dimethyl fumarate in bulk and capsules.Methods: An Inertsil ODS (150x4.6 mm, 5µ) column and a mobile phase containing acetonitrile: potassium dihydrogen phosphate buffer pH 6.8 (50:50% v/v) was used for this study. The flow rate was maintained at 1.0 ml/min; column temperature was fixed at 35 °C and UV detection was carried out at 210 nm. The forced degradation studies were performed and method was validated with as per ICH guidelines.Results: The retention time of dimethyl fumarate was found to be 3.3±0.02 min. The value of correlation coefficient between peak area and concentration was found to be 0.9993. The mean percent recovery of dimethyl fumarate in capsules was found in the range of 99.65 to 101.64%. The results of forced degradation studies indicated that the drug was found to be stable in basic, oxidative and thermal conditions while degraded in acidic conditions.Conclusion: It can be conducted from results that the developed HPLC method is simple, accurate, precise and specific. Results of stress testing study revealed that the method is stability indicating. Thus, this method can be used for routine analysis of dimethyl fumarate capsules and check their stability.  


Author(s):  
Meetali M. Chaphekar ◽  
Purnima Hamrapurkar

The concept of Quality by design (QbD) has recently gained importance in the area of analytical method development and involves understanding of the critical factors and their interaction effects by a desired set of experiments. So, the present work describes the development of Reverse Phase-High Performance Liquid Chromatography (RP-HPLC) method by QbD approach using Design of Experiments and subsequent validation for analysis of Vildagliptin in bulk drug and its pharmaceutical formulation. An efficient experimental design based on systematic scouting of all three key components of the RP‐HPLC method (Buffer pH, Organic Phase-% acetonitrile, Organic Modifier-Methanol) is presented. The significance and interaction effects of these parameters on the response variables (Retention time and tailing factor) were evaluated through statistical analysis tools like Analysis of Variance (ANOVA) and plots which revealed the final chromatographic conditions of the method. The developed method was validated and Forced degradation studies were also carried out in order to determine the stability-indicating nature of the method. The chromatographic separation was achieved on Jasco CrestPack RP C18 (250 × 4.6 mm, 5μ) column using Buffer (pH 6): Acetonitrile: Methanol (70:10:20 v/v) as mobile phase and detection was done using Photo-Diode Array (PDA) detector at 210 nm. The developed method of Vildagliptin is linear over a range of 5-15μg/ml having correlation coefficient R2 value as 0.999. The %RSD for precision and accuracy of the method was found to be less than 2%. Forced Degradation studies revealed that the method was found to be stability-indicating. The results showed that the proposed method is suitable for the precise and accurate determination of Vildagliptin in bulk and its formulation.


2021 ◽  
Author(s):  
Abderrazaq Hamdache ◽  
Lamia Grib ◽  
Celia Grib ◽  
Lydia Adour ◽  
Hakim Zatout ◽  
...  

2010 ◽  
Vol 93 (2) ◽  
pp. 523-530 ◽  
Author(s):  
Sérgio Luiz Dalmora ◽  
Maximiliano da Silva Sangoi ◽  
Daniele Rubert Nogueira ◽  
Lucélia Magalhães da Silva

Abstract An RP-HPLC method was validated for the determination of entecavir in tablet dosage form. The HPLC method was carried out on a Gemini C18 column (150 4.6 mm id) maintained at 30C. The mobile phase consisted of acetonitrilewater (95 + 5, v/v)/potassium phosphate buffer (0.01 M, pH 4; 9 + 91, v/v) pumped at a flow rate of 1.0 mL/min. Photodiode array detection was at 253 nm. The chromatographic separation was obtained with a retention time of 4.18 min, and the method was linear in the range of 0.5200 g/mL (r2 0.9998). The specificity and stability-indicating capability of the method was proven through forced degradation studies, which also showed that there was no interference of the excipients and an increase of the cytotoxicity only by the basic condition. The accuracy was 101.19, with bias lower than 1.81. The LOD and LOQ were 0.39 and 0.5 g/mL, respectively. Method validation demonstrated acceptable results for precision and robustness. The proposed method was applied for the analysis of tablet formulations, to improve QC and assure therapeutic efficacy.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Roghaieh Khoshkam ◽  
Minoo Afshar

A rapid and stability-indicating RP-HPLC method was developed for determination of l-carnitine in tablets. The separation was based on a C18 analytical column using a mobile phase which consisted of 0.05 M phosphate buffer (pH = 3): ethanol (99 : 1), including 0.56 mg/mL of sodium 1-heptanesulfonate. Column temperature was set at 50°C and quantitation was achieved by UV detection at 225 nm. In forced degradation studies, the drug was subjected to oxidation, hydrolysis, photolysis, and heat. Among the different stress conditions, the exposure to acidic and basic conditions was found to be an important adverse stability factor. The method was validated for specificity, selectivity, linearity, precision, accuracy, and robustness. The applied procedure was found to be linear in l-carnitine concentration range of 84.74–3389.50 µg/mL (r2=0.9997). Precision was evaluated by replicate analysis in which relative standard deviation (RSD) values for areas were found below 2.0%. The recoveries obtained (100.83%–101.54%) ensured the accuracy of the developed method. The expanded uncertainty (3.14%) of the method was also estimated from method validation data. Accordingly, the proposed validated and rapid procedure was proved to be suitable for routine analyzing and stability studies of l-carnitine in tablets.